• 제목/요약/키워드: Auxiliary system

검색결과 998건 처리시간 0.04초

A Three-Phase Line-Interactive UPS System to Eliminate the Inrush Current Phenomenon during Switching-in of an Auxiliary Load while Powering the Main Load

  • Bukhari, Syed Sabir Hussain;Ayub, Muhammad;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1623-1630
    • /
    • 2018
  • Normally, various auxiliary loads are installed along with the main load in industrial applications. Usually, load transformers are used to convey such types of auxiliary loads. The transformers become energized when the loads are turned-on, consequently, high amplitude of inrush current appears at the output of the uninterrupted power supply (UPS) system. To mitigate these high current amplitudes, this manuscript suggests a three-phase line-interactive UPS system to counter the inrush current during the turning-on of the auxiliary load transformer while powering the main load by using a current controlled inverter. Experimental results of a laboratory-sized prototype are provided in the support of the proposed UPS system for validation.

전류 및 전위 보조전극을 수직으로 배치하는 전위강하법을 이용한 접지저항의 측정 (Measurement of the Ground Resistance using the Fall-of-Potential Method with the Vertically-placed Current and Potential Auxiliary Electrodes)

  • 이복희;김기복;김유하
    • 조명전기설비학회논문지
    • /
    • 제26권3호
    • /
    • pp.53-60
    • /
    • 2012
  • The fall-of-potential method is commonly used in measuring the ground resistance of large-scaled grounding system and the current and potential auxiliary electrodes are horizontally arranged. Because the distances between the ground grid to be tested and auxiliary electrodes are limited in downtown areas, it is very difficult to measure accurately the ground resistance of large-scaled grounding system. In this paper, the fall-of-potential method of measuring the ground resistance with the vertically-placed current and potential auxiliary electrodes was examined and discussed. The validity and good accuracy of the proposed method of measuring the ground resistance were confirmed through various simulations and actual tests carried out in uniform and two-layer soil structures.

플라스틱 보조재를 갖는 영화관 의자 시트의 진동전달 특성 (Vibration Transfer Characteristic of Seat with the Auxiliary Plastic Member for Movie Theater Chair)

  • 강화중;김태균;문덕홍
    • 동력기계공학회지
    • /
    • 제18권6호
    • /
    • pp.45-50
    • /
    • 2014
  • In the previous paper, we have reported on the development of foaming sponge seat with the auxiliary spring member and suggested new possibility of the special seat with the auxiliary plastic member for movie theater chair. In this study, we have examined the major design parameters needed in the development of a foaming sponge seat in which the mesh type plastic member are inserted to improve the vibration transfer effect of a chair seat. Through analyzing several prototypes by applying experimentation as well as the experimental modal analysis method, it was confirmed that the effect of vibration transfer can be improved through the use of a mesh type plastic member and applied to the design of practical chair seat.

발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토 (A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant)

  • 선현규;홍영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

전기자 분산배치 집중권 PMLSM의 단부 효과 저감을 위한 보조극과 보조치 조합에 관한 연구 (A Study on Auxiliary Pole and Teeth Combinations for Edge Effect Reduction of Stationary Discontinuous Armature PM-LSM with Concentrated winding)

  • 김성진;김용재
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1611-1616
    • /
    • 2012
  • Recently, the stationary discontinuous armature Permanent Magnet Linear Synchronous Motor(PM-LSM) was suggested as a driving source for long-distance transportation system. However, as these motors arrange armatures discontinuously, there occurs an edge which causes the cogging force. This works as a factor that bothers acceleration and deceleration that takes place when movers enter into and eject from the armatures. Therefore, installation of auxiliary teeth on the edge of armature of PM-LSM is suggested in order to reduce cogging force caused by the edge when the armature is placed in a discontinuous arrangement. But length of auxiliary teeth can be changed if install it with auxiliary pole in order to decrease more and more edge cogging force. On this, in the study, decided on a design variable of auxiliary teeth and used 2-D FEA, and examined edge cogging force characteristic along this in order to grasp length of auxiliary teeth changed according to installation positions of an auxiliary pole.

민생용 열병합발전시스템의 최적운전에 관한 연구 (A Study on the Optimal Operation of the Private Cogeneration System)

  • 류승헌;이종범;김창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.896-898
    • /
    • 1996
  • This paper presents the optimal operation scheduling of the private cogeneration system connected with auxiliary equipments. And the optimal size of auxiliary equipments is determined through evaluations of the minimum operation cost. The optimal operation scheduling is established by using the linear programming method. Simulation results show that the auxiliary boiler is operated as an economical facility but the thermal storage tank is used as a back up facility for emergency.

  • PDF

다양한 보조설비를 가진 열병합발전시스템의 단기운전계획 (Short-term Operation Strategy of Cogeneration System with Auxiliary Equipments)

  • 이종범;정창호;류승헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.24-26
    • /
    • 1994
  • This paper describes a numerical model for the short-term operation strategy of the cogeneration systems. Especially this paper considered various auxiliary equipments used for the effective operation of cogeneration system. Minimum daily operation costs of topping cycle are calculated by using LP. Simulation results of some cases are analyzed and compared each other. Through these simulations the validity of the proposed model considered various auxiliary equipments is verified.

  • PDF

산업체 열병합발전시스템에서 최적운전계획 수립을 위한 진화 알고리즘을 이용한 GUI System 개발 (A Development of GUI System for Optimal Operational Scheduling on Industrial Cogeneration Systems Using Evolutionary Algorithms)

  • 정지훈;이종범
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권11호
    • /
    • pp.544-550
    • /
    • 2002
  • This paper describes a strategy of a daily optimal operational scheduling on the industrial cogeneration system. The cogeneration system selected to establish the scheduling consists of three units and several auxiliary devices which include three auxiliary boilers, t재 waste boilers and three sludge incinerators. One unit generated electrical and thermal energy using the back pressure turbine. The other two units generate the energy using the extraction condensing turbine. Three auxiliary devices operate to supply energy to the loads with three units. The cogeneration system is able to supply enough the thermal energy to the thermal load, however it can not sufficiently supply the electric energy to the electrical load. Therefore the insufficient electric energy is compensated by buying electrical energy from utility. In this paper, the evolutionary algorithms was applied to establish the optimal scheduling for the cogeneration systems. Also the GUI System was developed using established mathematics medeling and evolutionary algorithms in order that non-experts are able to establish operational scheduling. This results revel that the proposed modeling and strategy can be effectively applied to cogeneration system for paper mill.

Compositional rules of Korean auxiliary predicates for sentiment analysis

  • Lee, Kong Joo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권3호
    • /
    • pp.291-299
    • /
    • 2013
  • Most sentiment analysis systems count the number of occurrences of sentiment expressions in a text, and evaluate the text by summing polarity values of extracted sentiment expressions. However, linguistic contexts of the expressions should be taken into account in order to analyze sentimental orientation of the text meticulously. Korean auxiliary predicates affect meaning of the main verb or adjective in some ways while attached to it in their usage. In this paper, we introduce a new approach that handles Korean auxiliary predicates in the light of sentiment analysis. We classify the auxiliary predicates according to their strength of impact on sentiment polarity values. We also define compositional rules of auxiliary predicates to update polarity values when the predicates appear along with sentiment expressions. This approach is implemented to a sentiment analysis system to extract opinions about a specific individual from review documents which were collected from various web sites. An experimental result shows approximately 72.6% precision and 52.7% recall for correctly detecting sentiment expressions from a text.

보조 흡입구가 장착된 왕복동 압축기의 성능 분석 (Performance of a Reciprocating Compressor Equipped with Auxiliary Port)

  • 이용호;김현진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF