• 제목/요약/키워드: Auxiliary power system

검색결과 423건 처리시간 0.032초

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

직렬접속형 다이오드 정류기 시스템의 전류주입에 의한 고조파 저감 (Drawing Sinusoidal Input Currents of Series-Connected Diode Rectifiers by A Current Injection Technique)

  • 최세완;오준용;원충연;김영석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.346-349
    • /
    • 1999
  • This paper proposes a new series-connected diode rectifier which draws sinusoidal input currents. The proposed rectifier system is configured by adding an auxiliary circuit to the conventional 12-pulse series-connected diode rectifier and employing a current injection technique. A low kVA (0.02Po (PU) ) active current source injects a triangular current results in near sinusoidal input current from the utility with less than 1% THD. The resulting system is suitable for high voltage and high power applications. Experimental results is provided from a 220VA rectifier system.

  • PDF

노심손상빈도 평가를 위한 APR+ PAFS의 안전 해석 (Safety Analysis of APR+ PAFS for CDF Evaluation)

  • 강상희;문호림;박영섭
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.123-128
    • /
    • 2013
  • The Advanced Power Reactor Plus(APR+), which is a GEN III+ reactor based on the APR1400, is being developed in Korea. In order to enhance the safety of the APR+, a passive auxiliary feedwater system(PAFS) has been adopted in the APR+. The PAFS replaces the conventional active auxiliary feedwater system(AFWS) by introducing a natural driving force mechanism while maintaining the system function of cooling the primary side and removing the decay heat. As the PAFS completely replaces the conventional AFWS, it is required to verify the cooling capacity of PAFS for the core damage frequency(CDF) evaluation. For this reason, this paper discusses the cooling performance of the PAFS during transient accidents. The test case and scenarios were picked from the result of the sensitivity analysis in APR+ Probabilistic Safety Assessment(PSA). The analysis was performed by the best estimate thermal-hydraulic code, RELAP5/.MOD3.3. This study shows that the plant maintains the stable state without the core damages under the given test scenarios. The results of PSA considering this analysis' results shows that the CDF values are decreased. The analysis results can be used for more realistic and accurate performance of a PSA.

철도차량 보조전원장치의 효율향상을 위한 새로운 전력변환회로 구조 연구 (Research on High-Efficiency Power Conversion Structure for Railroad Auxiliary Power Supply(APS) System)

  • 조인호;정신명;이병희
    • 한국철도학회논문집
    • /
    • 제19권3호
    • /
    • pp.297-303
    • /
    • 2016
  • 본 논문은 철도차량에 사용되는 보조전원장치(APS)의 고효율화 및 경량화를 위한 방안으로 새로운 철도차량용 보조전원장치의 회로 구조를 제안한다. 제안하는 회로 구조는 기존의 보조전원장치 전력변환 흐름에서 중복 수행되고 있는 전력변환 단계를 단순화 하여, 스위치 소자의 부담을 경감하고 수동소자의 크기를 줄여 전력밀도를 높이는 것을 목적으로 하고 있다. 본 연구에서 제안하는 회로 구조는 기존 철도차량용 보조전원장치에 널리 이용되는 멀티레벨 컨버터를 기본 회로로 하고 있으며, 기존 회로의 1차 측 구조에 커패시터 소자를 추가하여 전력변환 스위치의 소프트스위칭 조건을 용이하게 하는 효과를 얻음과 동시에 추가되는 커패시터를 별도의 저전압 전원소스로 활용하고자 한다. 판토그래프 단에 위치하는 새로운 전원소스를 활용하여 철도차량에 탑재되는 배터리 충전용 컨버터의 에너지를 직접 공급받음으로써, 기존 주 전력변환 컨버터 용량 및 사이즈가 절감되는 효과를 얻을 수 있을 뿐만 아니라 전력변환 단계의 축소로 에너지 변환 효율도 향상되는 효과를 얻을 수 있다. 본 연구에서는 도시철도차량에서 사용되는 보조전원장치의 스펙을 적용하여 제안하는 회로를 디자인하고 타당성을 검증하였다.

철도차량 보조전원장치의 고효율-경량화를 위한 전력변환회로 연구 (Research on Power Converters for High-Efficient and Light-Weight Auxiliary Power Supplies (APS) in Railway System)

  • 이재범;조인호
    • 한국철도학회논문집
    • /
    • 제20권3호
    • /
    • pp.329-338
    • /
    • 2017
  • 최근 철도차량용 보조전원장치는 시스템의 경량화를 위해 기존 60Hz 저주파 변압기를 제거하고 고주파 구동과 절연 특성을 갖는 '절연형 dc/dc 컨버터'를 적용하는 구조가 주목받고 있다. 본 논문에서는 '절연형 dc/dc 컨버터를 적용한 보조전원장치 구조'에 대해서 설명하고, 다양한 분석을 통해 보조전원장치의 고효율 및 경량화에 적합한 dc/dc 컨버터 및 구조를 제안하고자 한다. 대용량 IGBT 소자의 고주파 스위칭(경량화)을 위해 필수적인 '영전압-영전류-스위칭'특성을 갖는 '공진형 컨버터'를 활용하여 다양한 보조전원장치용 전력변환장치 구조(1-Stage와 2-Stage)를 제안하였고, 각각의 구조에 적합한 컨버터 회로를 선정한 후 설계 및 시뮬레이션을 통해 비교하였다. 1-Stage 구조의 경우 공진형 컨버터만을 사용하였고, 2-Stage 구조의 경우 공진형 컨버터와 공진형 컨버터의 입력전압 변동을 최소화하는 Pre-regulator를 적용하였다. Pre-regulator로서 감압 컨버터 또는 승압 컨버터를 각각 적용하여 서로 다른 2-Stage 구조를 구성하고 각 방식의 손실을 비교하였다. 회로에 사용되는 소자들의 전압 및 전류 스트레스를 고려하여 소자를 선정하고 시뮬레이션을 통해 동작을 검증하였으며, 손실 분석을 통해 고효율 및 경량화에 가장 적합한 구조 및 회로를 제안하였다.

Design of Air-Lifted Seawater Propulsion System (ALSP) for Ecoships' Auxiliary Propulsion 1

  • Lee, Jae-hyuk
    • International journal of advanced smart convergence
    • /
    • 제10권2호
    • /
    • pp.15-20
    • /
    • 2021
  • We constructed an air-lifted seawater propulsion system for decreasing fuel consumption of the ships. The system has a form of pipes which can be easily installed on the sides of the ship. Seawater mixed with air, will rise along within the pipe, and will be discharged downward. If the directions of inlet / outlet of the pipe are designed properly, a propulsive energy can be obtained. We tested the system with a model ship in Jangsa port at Sokcho-city with a water depth of 2.5 meters. The system was supplied regulated air at 6 bars during the 3 tests. The model ship was moving forward at a rate of 0.18 meters per second. In case of large ships equipped zfrom clean energy.

Improved Bridgeless Interleaved Boost PFC Rectifier with Optimized Magnetic Utilization and Reduced Sensing Noise

  • Cao, Guoen;Kim, Hee-Jun
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.815-826
    • /
    • 2014
  • An improved bridgeless interleaved boost power factor correction (PFC) rectifier to improve power efficiency and component utilization is proposed in this study. With combined conventional bridgeless PFC circuit and interleaved technology, the proposed rectifier consists of two interleaved and magnetic inter-coupling boost bridgeless converter cells. Each cell operates alternatively in the critical conduction mode, which can achieve the soft-switching characteristics of the switches and increase power capacity. Auxiliary blocking diodes are employed to eliminate undesired circulating loops and reduce current-sensing noise, which are among the serious drawbacks of a dual-boost PFC rectifier. Magnetic component utilization is improved by symmetrically coupling two inductors on a unique core, which can achieve independence from each other based on the auxiliary diodes. Through the interleaved approach, each switch can operate in the whole line cycle. A simple control scheme is employed in the circuit by using a conventional interleaved controller. The operation principle and theoretical analysis of the converter are presented. A 600 W experimental prototype is built to verify the theoretical analysis and feasibility of the proposed rectifier. System efficiency reaches 97.3% with low total harmonic distortion at full load.

Underwater striling engine design with modified one-dimensional model

  • Li, Daijin;Qin, Kan;Luo, Kai
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권3호
    • /
    • pp.526-539
    • /
    • 2015
  • Stirling engines are regarded as an efficient and promising power system for underwater devices. Currently, many researches on one-dimensional model is used to evaluate thermodynamic performance of Stirling engine, but in which there are still some aspects which cannot be modeled with proper mathematical models such as mechanical loss or auxiliary power. In this paper, a four-cylinder double-acting Stirling engine for Unmanned Underwater Vehicles (UUVs) is discussed. And a one-dimensional model incorporated with empirical equations of mechanical loss and auxiliary power obtained from experiments is derived while referring to the Stirling engine computer model of National Aeronautics and Space Administration (NASA). The P-40 Stirling engine with sufficient testing results from NASA is utilized to validate the accuracy of this one-dimensional model. It shows that the maximum error of output power of theoretical analysis results is less than 18% over testing results, and the maximum error of input power is no more than 9%. Finally, a Stirling engine for UUVs is designed with Schmidt analysis method and the modified one-dimensional model, and the results indicate this designed engine is capable of showing desired output power.

증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증 (Verification of SPACE Code with MSGTR-PAFS Accident Experiment)

  • 남경호;김태우
    • 한국안전학회지
    • /
    • 제35권4호
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.