• 제목/요약/키워드: Auxiliary power system

검색결과 423건 처리시간 0.033초

철도차량 보조전원장치 특성 분석에 관한 연구 (A Study on Characteristic Analysis of Auxiliary Power Supply for Railway Vehicle)

  • 한영재;한성호;이태형;이수길;이영호
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.177-181
    • /
    • 2017
  • Auxiliary power supply for railway vehicle is a equipment that focuses on the service of passengers in a vehicle. It supplies power to controllers used in heating and cooling devices, fluorescent lamps, batteries and many other electrical equipments. Most of the auxiliary power supply for railway vehicle are mainly used for the round trips and circulation routes within the metropolitan area and have a capacity of 170~200 kVA. In this study, we developed the auxiliary power supply capacity to 240kVA for 200km/h class. As such, the auxiliary power supply is an important device for securing the reliability and safety of the railway vehicle and improving the passenger convenience, so the performance verification of the performance must be ensured. In this paper, 240kVA auxiliary power supply is developed. Also, performance of the auxiliary power supply manufactured through the analysis of various characteristics related to the auxiliary power supply was confirmed while operating the actual line.

100 Kw급 항공용 보조동력장치(APU) 개발 (Development of 100 Kw Power Class Airborne Auxiliary Power Unit)

  • 양수석;이대성;김승우
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.291-300
    • /
    • 1999
  • Currently under development is an airborne auxiliary power unit with 100 Kw equivalent power, which is composed of a centrifugal compressor, a reverse annular combustor, and a radial turbine. Air-foil bearings are used in this power unit to eliminate the oil supplying system, which can reduce the system complexity and weight. The high speed generator is adopted as an electric power generation and engine starting system, which can also eliminate the reduction gear system. Not only electric power but also pneumatic power is provided by bleeding the compressed air This power unit is aimed for the multi-purpose use such as a primary power unit In the army weapon system, an auxiliary power and environmental control unit in a next-generation tank, and a smoke generating unit.

  • PDF

한국형 고속열차 보조전원 시스템의 신뢰성 해석 (Reliability Analysis of Auxiliary Power System on Korea High Speed Train)

  • 서승일;박춘수;한영재;이태형;김기환
    • 한국철도학회논문집
    • /
    • 제7권4호
    • /
    • pp.356-359
    • /
    • 2004
  • In this paper, as the first step to assess and enhance the reliability of Korea High Speed Train, auxiliary power system is selected and reliability analysis is carried out. The auxiliary power system is classified into subsystems and functional analysis is conducted. Reliability block diagrams are drawn and reliability parametric analysis is performed. Analysis results show that the reliability of auxiliary power system depends on critical items. To grow the system reliability, activities should be concentrated on improvement of critical items.

고속전철용 보조전력변환장치 1,2군 동시 기동 (Simultaneous operation of two group of Auxiliary Block for Korean High Speed Train)

  • 조현욱;김연충;김태환;장경현;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1626-1632
    • /
    • 2007
  • Power Car PC1 and PC2 of Korean high speed train have a auxiliary block which consists of two PWM converter respectively. If a auxiliary block happens a critical failure, the other supplies power to full load of train. In this case, a stability of auxiliary block reduces by a increasing load. For increasing a stability of auxiliary block and train system, a auxiliary block consists of two group four PWM converter which operates simultaneously. If a group of a auxiliary block happens a critical failure, the other supplies power to load of a auxiliary block. This paper describes a method for simultaneous movement of auxiliary block which consists of two group four PWM converter.

  • PDF

고속전철용 보조전원장치 시스템 조합시험 (Combined test of Power Supply System for Korean High Speed Train)

  • 조현욱;김연충;김태환;장경현;김철호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.619-625
    • /
    • 2008
  • Electrical Power supply System conditions of korea high speed train consists of main transformer, four AC-DC PWM converter of Auxiliary Block, Battery Charger in Power Car and Trailer Car, Trailer Inverter, Auxiliary inverter. Main transformer, at nominal voltage of 25kv supplied to secondary winding nominal output Voltage 383Vac, The Auxiliary block consists of AC-DC converters for generating 670VDC power, Auxiliary inverters for ventilation and air compressor, Trailer car inverter provide three phase power supplies at 440Vac for air conditioning and heating. The Battery charger Trailer and Power car supplies 72VDC all necessary equipment to energize the trainset equipment and suppy essential control. This Paper introduces the combined test results of the power supply system for korea high speed train. The main purpose of this combined test is to verify the performance of the power supply system that is designed to operate up to full load test.

  • PDF

철도차량용 보조전원장치의 전향제어를 이용한 Flicker 제어 (The Flicker Control by Feed-forward for Stabilization of CVCF Inverter)

  • 박채운;신형진;조국춘;원충연
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.267-272
    • /
    • 1999
  • The auxiliary power supply system fur passenger service of railway car has been developed from MA(Motor-Alternator) to CVCF Inverter (Static Inverter). Generally, a customer wants to apply tile new control method and device for auxiliary power supply of railcar However, if the auxiliary power supply is supplied to extended existing line, the maintenance cost of the old system is less expensive than new developed system, so, the customer specifies that the auxiliary power supply has compatibility with existing one completely. At that time, the hardware is nearly same as existing system except small changes of accessories for better performance. This paper describes the flicker control using feed-forward method of auxiliary power supply system for new 50 electric railcars, which are delivered to Korean National Railroad (KNR) Kwa-chon Line. The existing power supply system has damping resistor box to stabilize the DC input (1.5 ㎸). At this time, for better system efficiency the new system has not include resistor box but new control method including feed-forward control is applied. This control algorithm realizes the better stabilization of input power compared to the result of the existing system, which includes resistor box

  • PDF

보조 컨버터를 이용한 HVDC 시스템의 특성개선 (Performance Improvement using Auxiliary Converter on HVDC System)

  • 김동희;이화춘;박성준;남해곤;최준호;김광헌
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.217-224
    • /
    • 2009
  • This paper presents a new AC/DC converter scheme for HVDC system to achieve a high power factor operation. The new AC/DC converter consists of two 12-pulse bridge converters in series: the primary and auxiliary converters. Ignition angles of the main and auxiliary converters are controlled independently to maintain the nominal DC voltage and control auxiliary voltage. The resulted DC voltage obtained by superimposing the above two phase modulated voltages can be controlled very rapidly over a wide range, and a high power factor operation is achieved. Performance improvements in power factor and harmonic distortion are validated by theoretic derivations and experiments with prototype HVDC system. With the proposed converters, investment for reactive power compensation and filter in HVDC system can be saved significantly.

객차 보조전원장치 interface를 위한 IEEE표준 (IEEE Standard for Passenger Tram Auxiliary Power System Interfaces)

  • 노성찬;임응규;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.534-546
    • /
    • 2002
  • The electrical interfaces among the components comprising the auxiliary power systems and their electrical interface with other train-borne systems are described. As such, this standard treats the auxiliary power system compononents as black boxes and addresses only their interface requirements.

  • PDF

발전소 직류 제어회로 과도현상 분석 및 보조계전기 선정 적합성 검토 (A Analysis of DC Control Circuit Transient and a Study of Auxiliary Relay Design Compatability in the Power Plant)

  • 선현규;홍영희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1948_1949
    • /
    • 2009
  • All the power generating station require dc auxiliary power systems to operate those dc components that must be available if a loss of ac power occur. Some examples of such components are auxiliary motors, circuit breakers, relays and solenoids. The dc source may be one common battery for both power and control or two separate batteries; one for power and another for control. Typically, a dc auxiliary power system is designed as an ungrounded system, instead of grounded system, so that a low-resistance ground fault on one of its two polarities will not affect the operation of the system, thus increasing system reliability and continuity of service. A ground detector should provide a high polarity-to-ground resistance so that a single ground fault occurring on the system will not affect the operation of that system. Sensitive relays have been known to energize momentarily while the cable and capacitive charge to ground shifts[1]. A power station had experienced this kind of incident and performed root cause analysis based on PC based simulation program known as PSpice. This simulation showed adapted relays on the system energize momentarily and design criteria on this relay should be corrected.

  • PDF

전력조절분배기의 보조전원 설계 (Auxiliary Power Interface Design for Power Control and Distribution Unit)

  • 박성우;장진백;박희성;윤희광
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.239-242
    • /
    • 2009
  • Power Control and Distribution Unit (PCDU) plays roles of power generation control for solar array panel, power storage control for battery system, power conversion for unregulated and regulated primary bus and power distribution to bus and payload system. The selection and design of the proper auxiliary power interface for PCDU depending on various mission is one of the most important step for electrical power subsystem design. In this paper, the general design approach of auxiliary power interface for PCDU which can be used for small-sized LEO satellites application is given. And, the auxiliary power design concept for always alived modules such as solar array regulator and house keeping module is also suggested.

  • PDF