• Title/Summary/Keyword: Auxiliary pole

Search Result 38, Processing Time 0.023 seconds

Modeling of auxiliary resonant inverter circuit using mediocrity power module (범용파워모듈로 구성된 보조 공진형 인버터의 특성 해석)

  • Lee, S.H.;Mun, S.P.;Kwon, S.K.;Lee, S.H.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.9-11
    • /
    • 2002
  • These days, electromagnetic radiation noise and switching losses of static converter become harmful. Many resonant inverters with radiation techniques solve their such problems. Auxiliary Resonant Commutated Pole Inverter (ARCP) was proposed. but it has two demerits. In circuit configuration. It isn't constructed by 2 in 1 IGBT modules, Besides, control is complicated because of neutral point voltage control and boost. current control. This paper proposes a new auxiliary resonant inverter which solved two demerits. In addition, it deals efficiency which compared with hard switching inverter and result of separation of power loss

  • PDF

A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch (토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Yu, Seung Hyup;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

A Study on the Improvement of Torque Characteristics of D.C Brushless Motor by Auxiliary Slot Method (보조 슬롯법에 의한 D.C Brushless Motor의 토오크특성 개선에 관한 연구)

  • Im, Dal-Ho;Kim, Saeng-Su;Son, Yung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.83-86
    • /
    • 1988
  • In all sorts of primary factor which produce torque ripple of d.c brushless motor cogging torque which is generated from relation between permanent magnet rotor and salient pole cannot controled by external control system. So in this paper cogging torque is analysed by simple method in which slot fuctuion is introduced. And for reducing counterplan of cogging torque d.c brushless motor which plot auxiliary slot by inequality interval is proposed. Thus the quantitative torque characteristics of new motor which designed by this method is analysed by F.E.M and validity of this new design is proved.

  • PDF

Performance Analysis of ARCP Inverter for Power System Interconnection (ARCP(Auxiliary Resonant Commutated Pole) 인버터의 특성분석)

  • Ha, Yo-Chul;Park, Sang-Ho;Kim, Hee-Joong;Han, Byung-Moon;Kim, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1065-1067
    • /
    • 2000
  • This paper describes performance analysis of ARCP Inverter, which can offer zero voltage switching at nominal voltage stress. The system consists of a voltage-source inverter with sort-switching module. Each main switch is connected in parallel with resonant capacitor and two auxiliary switches are placed in series with a resonant reactor for soft-switching capability. The described ARCP inverter could be effectively applied for active power filter reactive power compensator, and UPS.

  • PDF

A NEW High Efficiency Soft-Switching Three-Phase PWM Rectifier (새로운 고효율 소프트 스위칭 3상 PWM 정류기)

  • Mun Sang-Pil;Suh Ki-Young;Lee Hyun-Woo;Kwon Soon-Kurl
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.2 s.302
    • /
    • pp.49-58
    • /
    • 2005
  • A new soft switching three-phase PWM rectifier with simple circuit configuration and high efficiency has been developed. The proposed circuit is a kind of the auxiliary resonant commutated Pole(ARCP)converter The conventional ARCP converter requires three-auxiliary reactors and six-auxiliary switches for the soft switching auxiliary circuit and for these switching elements, a gate drive circuit and a control circuit are required, resulting in high part as a disadvantage. In the main circuit proposed in this paper, the auxiliary soft switching circuit is composed of two-auxiliary reactors, two-auxiliary switches and several diodes. In addition, common use of the PWM control circuit for two-switches will make the control circuit of the auxiliary switches simple. By means of function of the soft switching auxiliary circuit, the main switching element performs zero voltage switching operation and the auxiliary switches perform the zero current switching. In this paper, the circuit configuration and the operational analysis of the proposed circuit are described at first and then, experimental results will be reported. By using a prototype with 5[kW] capacity, the conversion efficiency of maximum $98.8[\%]$ and the power factor of $99[\%]$ or higher were obtained.

Direct Adaptive Control of Nonminimum Phase Systems Using Novel Estimation Algorithm (새로운 추정 알고리즘을 이용한 비최소 위상 시스템의 직접 적응 제어)

  • Lee, Seon-Woo;Kim, Jong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.377-380
    • /
    • 1992
  • This paper proposes a novel direct adaptive pole placement control algorithm which can be applied to continuous time nonminimum phase systems. The algorithm is based on Lyapunov's direct method. By introducing an auxiliary signal, a minimal error model is constructed in state space. Using the error model an estimation law is obtained via Lyapunov's second stability theorem. The global stability of the overall system is established.

  • PDF

A Study on the Low Cogging Torque of Brushless DC Motor (브러시레스 D\ulcornerC 모터의 코깅 토오크 저감에 관한 연구)

  • 임달호;김생수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.6
    • /
    • pp.361-367
    • /
    • 1988
  • In this study new design method with auxiliary slot on salient pole is proposed for the reduction of cogging torque which is the problem of corm type DC Brushless motor. And FEM(Finite element method) is adapted in trial motor which is designed by the method proposed in this paper. and learn the quantative characteristics of cogging torque. Comparing results of analysis with measurement it is porved that the proposed design has a propriety.

  • PDF

Adaptive Pole Placement Control of Nonminimum Phase Plants Using Reference Model (비최소 위상 공정의 기준모델을 이용한 극배치 적응제어)

  • 홍연찬;박용석;김중환;최계근
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.9
    • /
    • pp.1046-1050
    • /
    • 1988
  • A direct adaptive control algorithm for discrete-time SISO systems with arbitrary zeros is presented in a general way by making use of reference model. A linear equation error model is formulated for estimating both the controller parameters and the auxiliary parameters. With this algorithm, asyptotic tracking within an arbitrarily small error can be achieved.

  • PDF

Instant Torque of Salient Pole Rotor Type Single-Phase SRM According to Installed Permanent Magnet Starting Device or Not (영구자석 기동장치의 유무에 따른 회전자 돌극형 단상 SRM의 순간 토오크)

  • Kim Jun-Ho;Lee Eun-Woong;Lee Jong-Han;Kim Yong-Hun;Lee Hyun-Woo;Lee Min-Myung
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.959-961
    • /
    • 2004
  • A multi pole SRM(switched reluctance motor) is applied by the regulated current in regular sequence. So, it can be started by itself. But a single phase SRM can not be started by itself because the positive torque is only generated in the limited zone which the inductance is increased. Therefore, it is required auxiliary device for self starting which place the rotor in start position. The prototype was designed and fabricated in the previous research. It has the permanent magnet, which is installed in the bottom of the rotor, for self starting. But the permanent magnet affect the prototype during operation and cause the decrease of the torque and speed. The influence of the permanent magnet on the average torque and speed was already confirmed. On this paper, the instant torque of the prototype was calculated from the experiment results which is the inductance and current according to installed permanent magnet or not.

  • PDF

Analysis and Improvement for Single 6/6 SRM with a Saturable Area (자기 포화 영역을 갖는 단상 6/6 SRM의 자기 구조 해석 및 개선)

  • Oh, Seok-Gyu
    • Journal of the Korean Magnetics Society
    • /
    • v.27 no.2
    • /
    • pp.70-75
    • /
    • 2017
  • Single-phase SRM is cost competitive because it can reduce the number of switches for small, low-cost applications. However, since the single-phase SRM is difficult to start itself, methods for realizing self-starting by using auxiliary magnet or auxiliary pole have been studied. Recently, a method of self-starting by changing the shape of the rotor with a saturable area has been proposed. The purpose of this paper is to analyze the magnetic structure of single phase 6/6 SRM with a saturable rotor and to improve the magnetic structure of rotor with a saturable area. For this magnetic analysis, FLUX2D, a finite element method analysis program, was used.