• 제목/요약/키워드: Auxiliary energy

검색결과 372건 처리시간 0.03초

A Study on the Torque Performance to Capacitance of a Capacitor-run type Single Phase Induction Motor

  • Kim Cherl-Jin;Choi Chul-Yong;Baek Soo-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권1호
    • /
    • pp.20-26
    • /
    • 2005
  • Various kinds of practical machines using the single phase induction motor (SPIM) are utilized to control both speed and torque. In particular, the capacitor-run type SPIM has the characteristic that allows the motor torque to be altered by auxiliary capacitance variation. In this study, we manifest an equivalent model having a more simplified configuration, and clarify the relationship between torque and capacitance. Also, we design an experimental controller that is able to perform speed control with ease by the phase angle control of the AC input voltage. Validity of this study is confirmed through the simulation and experimental results obtained.

능동 클램프 모드로 동작하는 단일 전력 AC/DC 컨버터에 의한 역률개선 (Power Factor with Single Power Stage AC/DC Converter Operated in Active-Clamp Mode)

  • 윤신용;백수현;김용;김철진;어창진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권8호
    • /
    • pp.392-401
    • /
    • 2001
  • This paper presents the single-stage high power factor AC to DC converter operated in active-clamp mode. The proposed converter is added active-clamping circuit to boost-flyback single-stage power factor corrected power supply. The active-clamping circuit limits voltage spikes, recycles the energy trapped in the leakage inductance, and provides a mechanism for achieving soft switching of the electronic switches to reduce the switching loss. The auxiliary switch of active-clamping circuit uses the same control and driver circuit as the main switch to reduce the additional cost and size. To verify the performance of the proposed converter, a 100W converter has been designed. The proposed converter gives good power factor correction, low line current harmonic distortions, and tight output voltage regulation, as used unity power factor.

  • PDF

고온 초전도선재를 이용한 사고 전류 제한 장치의 개념 설계 및 효용 평가 (The Conceptual Design and Estimate of Fault Current Limiter Using High-Tc superconducting Tape)

  • 이승제;이찬주;장미혜;김태중;현옥배;고태국
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.134-137
    • /
    • 1999
  • It is certain that the power quality will be very important at 21 century. Especially instant power shortage or power fault will occur serious problems. Accordingly stable power supplication is very technical problem. There are many way to make stable supplication as auxiliary generator, but this is long time delay complement. To solve this problem the superconducting magnetic energy storage is introduced. High Tc superconductor is more commercial.

  • PDF

통신장비실의 열환경 개선방안에 관한 연구 -TDX-10, TDX-100, 5ESS-2000, PCM실 중심으로- (A Study for Improving the Thermal Environment of Telecommunication Equipment Room -based on TDX-10, TDX-100, 5ESS-2000, PCM room-)

  • 조춘식;이승복
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.87-94
    • /
    • 2004
  • The purpose of this study is to improve thermal environment of telecommunication equipment rooms that hold TDX-10, TDX-100, 5ESS-2000, PCM of the latest telecommunication equipment. Analysis program is used the commercial CFD code, Star-CD and DOE-2.1E. The result has been compared by the energy consumption and the temperature contour at the 1 m height of room for each case. Different methods such as the relocation of the existing air-conditioner, the inflow of the ambient air into room, the installation of the forced fan and the cooling system equipment of the duct-connection type have been used to test for improvement of thermal environment. The analysis shows that most efficient method is the inflow of the ambient air into room but auxiliary equipment should be needed to prevent the local thermal spot.

Novel Zero-Current-Switching (BCS) PWM Switch Cell Minimizing Additional Conduction Loss

  • Park, Hang-Seok;Cho, B.H.
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제12B권1호
    • /
    • pp.37-43
    • /
    • 2002
  • This paper proposes a new zero-current switching (ZCS) pulse-width modulation (PWM) switch cell that has no additional conduction loss of the main switch. In this cell, the main switch and the auxiliary switch turn on and turn off under zero current condition. The diodes commutate softly and the reverse recovery problems are alleviated. The conduction loss and the current stress of the main switch are minimized, since the resonating current for the soft switching does not flow through the main switch. Based on the proposed ZCS PWM switch cell, a new family of dc to dc PWM converters is derived. The new family of ZCS PWM converters is suitable for the high power applications employing IGBTs. Among the new family of dc to dc PWM converters, a boost converter was taken as an example and has been analyzed. Design guidelines with a design example are described and verified by experimental results from the 2.5㎾ prototype boost converter operating at 40KHz.

주 스위치의 전도손실을 최소화한 ZVT 부스터 컨버터 (ZVT boost converter with minimizing conduction losses of the main switch)

  • 진기호;강안종;김태우;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.95-98
    • /
    • 2003
  • A ZVT PWM Boost Converter is proposed to reduce current stresses and conduction losses of main switch in a conventional circuit. By attaching resonant inductor Lr1 in parallel with capacitor Cr, the resonant circulating current is diverted to the additional component and then the main switch is subjected to minimum current stresses same as those in their PWM counterparts. Moreover, the operation of the auxiliary switch in a half wave mode to prevent reverse resonant energy from freewheeling can be able to lessen the conduction losses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed circuit.

  • PDF

18-step Back-to-Back Voltage Source Converter with Pulse Interleaving Circuit for HVDC Application

  • Lee, Hye-Yeon;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon;Choi, Nam-Sup;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.435-442
    • /
    • 2010
  • This paper proposes an 18-step back-to-back (BTB) voltage source converter using four sets of 3-Level converter modules with auxiliary circuits to increase the number of steps. The proposed BTB voltage source converter has the independent control capability of active power and reactive power at the interconnected ac system. The operational feasibility of the proposed BTB converter was verified through many simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was verified through experimental results with a scaled hardware prototype. The proposed BTB converter could be widely applied for interconnecting the renewable energy source to the power grid.

콘덴서 단상 유도전동기의 콘덴서 용량의 최적 선정에 관한 연구 (Optimal Selection of Capacitor for a Capacitor Run Single-Phase Induction Motor)

  • 이병삼;김경호;허두석;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.24-26
    • /
    • 2002
  • The recent emphasis on energy conservation demands an improvement of the efficiency of single-phase induction motors. To take the efficiency operation of the capacitor run single-phase induction motor with auxiliary and main winding, it is very important to select the capacitance value. This paper describes the theoretical analysis method of a single-phase induction motor which is based on the rotating field theory, using the method of symmetrical components. The optimal selection method of capacitance is proposed.

  • PDF

USING REMOTELY SENSED DATA TO ESTIMATE THE SURFACE HEAT FLUXES OVER TAIWAN'S CHAIYI PLAIN

  • Chang, Tzu-Yin;Liou, Yuei-An
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.422-425
    • /
    • 2007
  • Traditionally, surface energy fluxes are obtained by model simulations or empirical equations with auxiliary meteorological data. These methods may not effectively represent the surface heat fluxes in a regional scale due to scene variability. On the other hand, remote sensing has the advantage to acquire data of a large area in an instantaneous view. The remotely sensed data can be further used to retrieve surface radiation and heat fluxes over a large area. In this study, the airborne and satellite images in conjunction with meteorological data and ground observations were used to estimate the surface heat fluxes over Taiwan's Chaiyi Plain. The results indicate that surface heat fluxes can be properly determined from both airborne and satellite images. The correlation coefficient of surface heat fluxes with in situ corresponding observations is over 0.60. We also observe that the remotely sensed data can efficiently provide a long term monitoring of surface heat fluxes over Taiwan's Chaiyi Plain.

  • PDF

고출력용 산업안전 보조전원의 Supercapacitor (Supercapacitor of Auxiliary Electric Power Source in Industrial Safety for High Output)

  • 허진우;강안수
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2003년도 추계학술대회
    • /
    • pp.335-343
    • /
    • 2003
  • In the electrode fabrication of unit cell, it was ascertained that electrochemical characteristics were greatly increased with 90 wt.% of BP-20, 5 wt.% of Super P and 5 wt.% of mixed binder [P(VdF-co-HFP) : PVP =7 : 3] The self-discharge of unit cell showed that diffusion process was controlled by the ion concentration difference of initial electrolyte due to the characteristics of Electric Double Layer Capacitor (EDLC) charged by ion adsorption in the beginning, but this by current leakage through the double-layer at the electrode/electrolyte interface had a minor effect and voltages of curves were remained constant regardless of electrode material. The electrochemical characteristics of 2.3 V/3,000 F grade EDLC were as follows: 0.35 m of DC-ESR (100 A discharge), 0.14 mof AC-ESR (AC amplitude 100 mV), 2.80 Wh/kg (3.73 Wh/L) of energy density and 4.64 kW /kg (6.19 kW/L) of power density. Power output was compatible with electric vehicle applications, uninterrupted power supply and engine starter, in due consideration of Ragone relations.

  • PDF