• 제목/요약/키워드: Auxiliary Air

검색결과 176건 처리시간 0.024초

KTX 제동장치의 국산화 개발과 성능시험 (The Development for Localizing KTX Brake Devices and Performance Test)

  • 소진섭;이승구;황상규;금종호;곽수태;김종렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.630-636
    • /
    • 2011
  • Air brake system of KTX effectively distributes air to brake panel in each bogie. System consists of carrying bogie brake panel, motor bogie brake panel, driver's valve panel, pneumatic auxiliary panel and other accessories. For the prove endurance, confirm test number. Distributor and control moderable magnet valve are 500,000 times and respectively, carrying bogie MR/BP cut-out cock are 12,000 times. Tests satisfy all of condition until now. Developments conduct a performance test to brake tester of domestic manufacturer and operating authority.

  • PDF

공기극 채널 형상이 직접 메탄올 연료전지의 성능에 미치는 영향 (Effect of air flow channel configuration on performance of direct methanol fuel cells.)

  • 황용신;최훈;차석원;이대영;김서영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.137-140
    • /
    • 2007
  • We consider the optimum air flow channel design for DMFC's in the present study. The effect of pressure drop across the inlet and outlet of a stack on the performance of a DMFC is the optimization of such geometric parameters is crucial to minimize the parasitic power usage by the auxiliary devices such as fuel pumps and blowers. In this paper, we present how the pressure drop control can optimize the driving point of a DMFC stack. Further, we show how the optimal fuel utilization ratio can be achieved, not degrading the performance of DMFC stacks. Overall, we discuss how the flow channel design affects the selection of balance of plant(BOP) components, the design of DMFC systems and the system efficiency.

  • PDF

이산화탄소, HFC-l34a, HCFC-22의 열역학적 상태량 계산 절차의 응용 (Application of Procedures to Calculate Thermodynamic Properties of Carbon Dioxide, HFC-l34a and HCFC-22)

  • 박형준;박경근
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.389-396
    • /
    • 2003
  • Systematic methods to calculate thermodynamic properties of carbon dioxide, HFC-l34a and HCFC-22 are presented. First, application of a basic method to identify the saturation state with given temperature or pressure is attempted and the feasibility of auxiliary equations is tested. Next, detailed procedures are suggested to tell a phase when temperature/pressure and another property are specified. Finally Newton-Raphson method is applied to calculate unknown thermodynamic properties fixing the state with the two independent properties specified. The procedures described here are utilized to develop a computer program, which is used to find the relation between temperature and pressure with maximum isobaric heat capacity for super-critical carbon dioxide.

Evaluation of the cavitation effect on liquid fuel atomization by numerical simulation

  • Choi, Sang In;Feng, Jia Ping;Seo, Ho Suk;Jo, Young Min;Lee, Hyun Chang
    • Korean Journal of Chemical Engineering
    • /
    • 제35권11호
    • /
    • pp.2164-2171
    • /
    • 2018
  • Heavy duty diesel vehicles deteriorate urban air quality by discharging a large volume of air pollutants such as soot and nitrogen oxides. In this study, a newly introduced auxiliary device a fuel activation device (FAD) to improve the combustion efficiency of internal engines by utilizing the cavitation effect was closely investigated by the fluid flow mechanism via a numerical analysis method. As a result, the FAD contributed to fuel atomization from the injection nozzle at lower inlet pressure by reducing the pressure energy. The improved cavitation effect facilitated fuel atomization, and ultimately reduced pollutant emission due to the decrease in fuel consumption. The axial velocity along the flow channel was increased 8.7 times with the aid of FAD, which improved the primary break-up of bubbles. The FAD cavitation effect produced 1.09-times larger turbulent bubbles under the same pressure and fuel injection amount than without FAD.

태양열 난방시스템의 최적 유량에 관한 연구 (A Study on the Optimal Water Flow Rate of the Solar Heating System)

  • 성관제;김효경
    • 대한설비공학회지:설비저널
    • /
    • 제12권1호
    • /
    • pp.2-11
    • /
    • 1983
  • The solar energy retention rate of a flat plate collector can be increased by increasing water flow rate through the collector which also increases the pumping energy incurred in obtaining that solar energy. The problem of optimal flow rate is formulated to fit within the framework of pontryagin's maximum principle and with a few simplifying assumptions, an optimal solution that can be easily implemented is obtaincd, The optimal solution is used in the simulation of a solar heating system using actual climatological data and the results are compared with that of on-off control. The result that not only the object function but, In some cases, also the solar energy retention rate the collector is increased. In is also found that the optimal control gets more advantageous as the solar insolation level gets lower, and also as tile cost of auxiliary heating fuel gets higher.

  • PDF

태양열난방장치 설계를 위한 f-chart 개발 (Development of f-chart for the Design of Solar Heating Systems)

  • 송달순;유성연
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.292-298
    • /
    • 1986
  • The new f-chart capable of estimating long-term thermal performance of solar space and water heating systems was developed. The system comprise a flat plate solar collector, heat exchanger, storage tank filled with water, auxiliary fuel fired heater, and a house structure. The information obtained from many simulations of solar heating systems has been used to develop this f-chart. Actual hourly meteorological data collected in Seoul, Daejeon, Kwangju and Daegu, Korea from 1979 to 1983 have been utilized in these simulations. The new f-equation is as follows: $$f=1.034Y_{-}0.0968X_{-}0.2235Y^2+0.0043X^2+0.0144Y^3$$. The system performance estimates obtained from the developed f-chart are in close agreement with the results of experiment.

  • PDF

태양열주택의 난방성능에 관한 연구 (A Study on the Thermal Performance of a Solar House by a Computer Simulation)

  • 이상천
    • 대한설비공학회지:설비저널
    • /
    • 제7권2호
    • /
    • pp.64-72
    • /
    • 1978
  • The determination of solar collector area requires a thermal simulation to evaluate the performance of a solar house. This study comprises a simulation of system performance including a solar house, flat-plate collectors, a water type storage tank and an auxiliary heater. Developing the steady state performance equations of each equipment, and using the actual monthly average weather data for several recent years, this study evaluates the hourly performance of a solar house model. As a result, it is shown that the desirable collector area in Seoul is 1.4-1.6 times larger than the heating area in the case of non-selective surface, 0.8-1.0 times in the case of selective surface.

  • PDF

제어밸브의 유량특성에 따른 에어스프링의 성능 변화 (Effect of Control Valve Flow Rates Characteristics on the Performance of an Air Spring)

  • 한승훈;장지성;지상원
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.8-14
    • /
    • 2016
  • This study describes the effect of the critical pressure ratio of a control valve on the performance of an air spring system composed of an air spring, auxiliary chamber, control valve and mass in order to suggest a more efficient design for an air spring system. The critical pressure ratio of the control valve is assumed to have a fixed value, but the critical pressure ratio of the control valve is known to have various values between 0.05 and 0.6, and the effect of the variation of the critical pressure ratio on the performance of the air spring system has not yet been reported. The analysis derives nonlinear and linear governing equations of the air spring system, including the critical pressure ratio of the control valve. This simulation study is presented to show that the impedance and transmissibility characteristics of the air spring system change due to variations in the critical pressure ratio of the control valve as well as its sonic conductance. As a result, the critical pressure ratio of the control valve should be maintained as large as possible to improve the vibration isolation characteristics of the air spring system.

흡열판에 돌출형 삼각 개구부가 설치된 가정용 태양열 공기가열기의 열성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of a Domestic Solar Air Heater with Protruding Triangular Openings on the Absorber Plate)

  • 김현곤;부준홍
    • 한국태양에너지학회 논문집
    • /
    • 제36권2호
    • /
    • pp.41-51
    • /
    • 2016
  • A solar air heater was designed for supplementary domestic heating. The absorber plate had a series of protruding notches which had triangular openings on the front surface of the absorber plate to direct partial air flow to the rear surface and to enhance the convective heat transfer to the flowing air. The height of the opening as well as the opening configuration was determined by preceding numerical simulations. The experimental model had an absorber plate of 0.78-m width and 1.0-m length which was coated with black paint. The air temperature increased as much as $18^{\circ}C$ for $90-m^3/h$ flow rate when the absorber plate was inclined by $45^{\circ}$ for a clear-day solar irradiation of about $906W/m^2$. The collector efficiency ranged from 69 to 74%. Considering the simplicity of the structure and low manufacturing cost, the solar air heater might have competence as an auxiliary heating device for domestic use. On-site experimental results are presented with discussion for various solar irradiations and air flow conditions.

공회전 제한장치 차량에서 냉방 성능 유지를 위한 축냉 시스템 적용에 대한 연구 (Feasibility Study of Cold Storage System to Maintaining Cooling Performance for ISG Vehicle)

  • 이대웅
    • 설비공학논문집
    • /
    • 제28권1호
    • /
    • pp.7-14
    • /
    • 2016
  • This study explores the feasibility of a cold storage system to provide thermal comfort for idle stop and go (ISG) vehicles. ISG function is the most valuable and environmental friendly technology in the current automobile industry. However, when an ISG vehicle stops, meaning when the engine standstill, the air-conditioning system does not work, because the compressor also stops. Therefore, passenger thermal comfort is not maintained, as cold air is not provided in the cabin. Consequently, many automakers have studied electric air-conditioning systems based on electrically-driven compressors or cold storage systems using phase-change materials. The experiments herein were conducted for the feasibility testing of different types of cold storage heat-exchangers, cold storage mediums, and thermo-expansion valves with current air-conditioners. The auxiliary cold storage system, filled with phase-change materials, was located behind the evaporator and almost stacked on top of it. In the experimental results, the air discharge temperature rate of increase was better than the conventional air-conditioning system when the compressor stopped and thermal comfort was maintained with $1.9{\sim}4.3^{\circ}C$ decreases within 60 seconds. The #1 cold storage heat-exchanger (CSH), #2 thermo-expansion valve (TXV) and #2 phase change material (PCM) were chosen because of the best temperature rise delay. It was concluded that a cold storage system is an effective solution for ISG vehicles to maintain thermal comfort during short engine stops.