Placement Standard Research of Auxiliary Probes when Measuring Ground Impedance (접지임피던스 측정시 보조전극의 배치 기준 연구)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1984-1991
    • /
    • 2011
  • Among ground impedance measurement methods, the fall-of-potential method is the most thorough and reliable method. In the fall-of-potential method, ground electrode and auxiliary probes are placed in a straight line, and then, auxiliary potential probe is moved away from the ground electrode. The point at which plotted resistance curve flattens out is taken as right position of auxiliary potential probe. However, in some cases, it is hard to place ground electrode and auxiliary probes in a straight line. Therefore, we provided alternative placement method in this research. The method can be easily applicable to placing auxiliary probes. Also, this paper analyzed and compared ground impedance measurement standards of large grounding systems. Based on the analysis, practical measurement method using an earth tester was proposed. The proposed methods presented in this paper will be useful when determining locations of auxiliary probes in alternative positions, and the methods can be applied practically and easily.

Measurement Error Analysis of Ground Resistance Using the Fall-of-Potential Method According to the Locations of Auxiliary Probes (전위강하법에 의한 접지저항 측정시 보조전극의 위치변화에 따른 오차 분석)

  • Kim, Dong-Woo;Gil, Hyoung-Jun;Kim, Dong-Ook;Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Hyang-Kon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.222-231
    • /
    • 2010
  • This paper presents numerical analysis of measurement errors of ground electrode using the fall-of-potential method. In order to analyze ground resistance error according to the positions of auxiliary probes, firstly, national and international standards were researched. Secondly, numerical ground resistance error of hemispheric electrode was analyzed according to the locations of auxiliary probes and the angle between probes. Then, error-reduced positions of auxiliary probes were shown according to the distance to auxiliary current probe versus ground electrode size. Finally, error compensation method was presented. The results presented in this paper provide useful information regarding ground resistance error of alternative positions of auxiliary probes in case that the auxiliary probes could not be located at the proper position in such cases as there are buildings, roadblock or underground metallic pipe at that position.

Fast Auxiliary Channel Design for Display Port (디스플레이 포트를 위한 고속 보조 채널 설계)

  • Jin, Hyun-Bae;Moon, Yong-Hwan;Jang, Ji-Hoon;Kim, Tae-Ho;Song, Byung-Cheol;Kang, Jin-Ku
    • Journal of IKEEE
    • /
    • v.15 no.2
    • /
    • pp.113-121
    • /
    • 2011
  • This paper presents the design of a fast auxiliary channel bus for DisplayPort 1.2 interface. The fast auxiliary channel supports Manchester transactions at 1Mbps and fast auxiliary transactions at 780Mbps. The Manchester transaction is used for managing the main link and auxiliary channel and the fast auxiliary transaction is for data transfer via the auxiliary channel. Simplified serial bus architecture is proposed to be implemented in fast auxiliary channel. The fast auxiliary channel transmitter and receiver are implemented with 7,648 LUTs and 6,020 slice register synthesized in Xilinx Vertex4 FPGA and can be operated at 72MHz to support 720Mbps.

A Safety Improvement for the Design Change of Westinghouse 2 Loop Auxiliary Feedwater System (웨스팅하우스형 원전의 보조급수계통 설계변경 영향 평가)

  • Na, Jang Hwan;Bae, Yeon Kyoung;Lee, Eun Chan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.9 no.1
    • /
    • pp.15-19
    • /
    • 2013
  • The auxiliary feedwater is an important to remove the heat from the reactor core when the main feedwater system is unavailable. In most initiating events in Probabilistic Safety Assessment(PSA), the operaton of this system is required to mitigate the accidents. For one of domestic nuclear power plants, a design change of a turbine-driven auxiliary feedwater pump(TD-AFWP), pipe, and valves in the auxiliary system is implemented due to the aging related deterioration by long time operation. This change includes the replacement of the TD-AFWP, the relocation of some valves for improving the system availability, a new cross-tie line, and the installation of manual valves for maintenance. The design modification affects the PSA because the system is critical to mitigate the accidents. In this paper, the safety effect of the change of the auxiliary feedwater system is assessed with regard to the PSA view point. The results demonstrate that this change can supply the auxiliary feedwater from the TD-AFWP in the accident with the motor-driven auxiliary feedwater pump(MD-AFWP) unavailable due to test or maintenance. In addition, the change of MOV's normal position from "close" to "open" can deliver the water to steam generator in the loss of offsite power(LOOP) event. Therefore, it is confirmed that the design change of the auxiliary feedwater system reduces the total core damage frequency(CDF).

A study on the practice application of oral hygiene auxiliary supplies and oral health status ofpatients in 'S' university dental clinic (치위생과 실습실 내원환자의 구강위생보조용품 사용유무와 구강건강상태와의 관계)

  • Nam, Sang-Mi
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.373-381
    • /
    • 2011
  • Objectives : The purpose of this study was to investigate the relationship among the practice application of oral hygiene auxiliary supplies, oral health state of patients in S university dental clinic. Methods : The subject in this were 261 patients who got a scaling at the oral hygiene practice lab in the department of dental hygiene in S university dental clinic from April 1 to May 31, 2010. For the data analysis, an SPSS WIN 11.5 program was used and its signification level was 0.05. Results : 1. For the oral health state according to sex distinction, it showed the men's 0.78 MT index was higher than women's 0.48 MT index and statistically significant difference. 2. For FT index, women(4.72) was higher than men(3.50) and it showed statistically significant difference(p<0.05). 3. For the oral health state according to sex distinction, Why not use oral hygiene auxiliary supplies showed statistically significant difference(p<0.05). 4. For the practice application of oral hygiene auxiliary supplies according to age distinction, 18.5% more than 30 years replied as I use interdental brush and it showed statistically significant difference. 18.5% more than 30 years replied as I use powered brush and it showed statistically significant difference(p<0.05). 5. For the oral health state according to the practice application of oral hygiene auxiliary supplies distinction, there were significant difference that dental floss, interdental brush, mouth rinse product, Why not use oral hygiene auxiliary supplies(p<0.05). Conclusions : The findings of this study were lower than the utilization of oral hygiene auxiliary supplies. Therefore, to increase the use of oral hygiene auxiliary supplies to patients of the appropriate selection and correct usage of oral hygiene auxiliary supplies and the resulting effects have sufficient training to practice more efficiently should be.

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

Compositional rules of Korean auxiliary predicates for sentiment analysis

  • Lee, Kong Joo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.3
    • /
    • pp.291-299
    • /
    • 2013
  • Most sentiment analysis systems count the number of occurrences of sentiment expressions in a text, and evaluate the text by summing polarity values of extracted sentiment expressions. However, linguistic contexts of the expressions should be taken into account in order to analyze sentimental orientation of the text meticulously. Korean auxiliary predicates affect meaning of the main verb or adjective in some ways while attached to it in their usage. In this paper, we introduce a new approach that handles Korean auxiliary predicates in the light of sentiment analysis. We classify the auxiliary predicates according to their strength of impact on sentiment polarity values. We also define compositional rules of auxiliary predicates to update polarity values when the predicates appear along with sentiment expressions. This approach is implemented to a sentiment analysis system to extract opinions about a specific individual from review documents which were collected from various web sites. An experimental result shows approximately 72.6% precision and 52.7% recall for correctly detecting sentiment expressions from a text.

The Approximation for the Auxiliary Renewal Function (보조재생함수에 대한 근사)

  • Bae, Jong-Ho;Kim, Sung-Gon
    • The Korean Journal of Applied Statistics
    • /
    • v.20 no.2
    • /
    • pp.333-343
    • /
    • 2007
  • The auxiliary renewal function has an important role in analyzng queues in which the either of the inter-arrival time and the service time of customers is not exponential. As like the renewal function, the auxiliary renewal function is hard to compute although it can be defined theoretically. In this paper, we suggest two approximations for auxiliary renewal function and compare the two with the true value of auxiliary renewal function which can be computed in some special cases.

Soft Switching boost converter for reduction of switch stress (스위치 스트레스 저감이 가능한 소프트 스위칭 부스트 컨버터)

  • Park, Seung-Won;Kim, Jun-Gu;Kim, Jae-Hyung;Eom, Ju-Kyoung;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.155-157
    • /
    • 2009
  • This paper proposed a soft switching boost converter with an auxiliary circuit, and a modified control method for reduction of switch stress. The proposed converter applies an auxiliary circuit, which is added to the conventional boost converter and used to achieve soft switching for both a main switch and an auxiliary switch. The auxiliary circuit consist of a resonant inductor and two capacitors, an auxiliary switch. The main switch is operated ZVS turn-on, turn-off also auxiliary switch is operated ZCS turn-on, ZVS turn-off. The proposed soft switching boost converter has lower switch loss and higher efficiency than conventional soft switching boost converter.

  • PDF

Combustion Characteristics in Various Primary and Auxiliary Air Flux Conditions at a Coaxial Swirling Diffusion Combustor (동축선회 확산연소기의 1차 및 보조공기유량 변화에 따른 연소배출특성)

  • Lee, Y.S.;Oh, S.W.;Bae, D.S.;Lee, D.H.
    • Journal of Power System Engineering
    • /
    • v.6 no.3
    • /
    • pp.17-23
    • /
    • 2002
  • The purpose of this study is to investigate the combustion emission characteristics changing auxiliary air injection in combustion field of coaxial swirling diffusion combustor. For this purpose, mean temperature, CO, CO2, O2 and HC concentration were measured by changing excess air ratio and auxiliary air injection. As a result of this study, mean temperature, CO2 emission were increased and CO emission decreased by increasing auxiliary air. Therefore, this paper showed the auxiliary air injection effected strongly on flame structure and combustion emission characteristics.

  • PDF