• Title/Summary/Keyword: Automotive Air Conditioner

Search Result 72, Processing Time 0.019 seconds

A Study on Air-Conditioning System for Excavator using Forced Exhaust (강제배기를 이용한 굴삭기 공기조화 시스템에 관한 연구)

  • Hwang, J.H.;Jeong, C.S.;Ko, J.H.;Yang, S.Y.
    • Journal of Drive and Control
    • /
    • v.10 no.2
    • /
    • pp.23-29
    • /
    • 2013
  • The excavator is used in a variety of construction environments. There are many kinds of risk like falling rocks or harmful dust. The excavator cabin protects the operator not only from these harmful environments but also provides a comfortable working environment. By the way, the excavator cabin consumes a lot of energy for cabin air conditioner. For this reason, the research is required to reduce energy consumption. This study suggests the air conditioning system for excavator using forced exhaust. First, the forced exhaust system simulated by AMESim tool and surveyed the applicability. Using AMESim simulation, it was investigated the effect of cabin inside temperature by intake flow rate and intake air temperature. The experiment executed using the 1.5 ton excavator and field tested according to the intake flow rate. Finally, verified the applicability on the air conditioning system for excavator using forced exhaust.

A Study on the Heat Load Transferred to a Passenger Vehicle (자동차 열부하의 계산)

  • 오상한;이창원;원성필
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.50-59
    • /
    • 1996
  • The computer simulation program that calculates the transient heat load transferred to a passenger vehicle has been developed. Method for modeling mathematically various kinds of the heat load was presented and the derived equations were solved numerically. To find out the accuracy of the simulation program, the correlation of experimental and analytical results was demonstrated. By using this program, the typical characteristics about temperature distribution and instantaneous or of vehicle body color, material of glass, air-conditioning capacity, driving direction, and speed. Under a steady-state condition, the ratios of the heat load, resulting form vehicle body, glass, and interior part, were 35%, 29%, and 36%, respectively.

  • PDF

A Study on Refrigeration Performance of Vehicle HVAC System for Sub-Cooling Improvement (서브쿨링향상을 위한 차량공조 시스템의 냉방성능에 관한 연구)

  • 박만재
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2004
  • The general method which changes sub-cooling of refrigerant is to control the expansion valve in the state of mixing with liquid and gas phase. In this study, the performance of vehicle air conditioning system is to control either changing the expansion valve or adding the sub condenser. Therefore, this research finally is tested in case of the fourth test procedure, the second test was suitable for a valve opening area due to adjusting valve slope in comparison with the other test. The other test except for the second test happened to do liquid back due to the excessively liquified refrigerant into the system. In conclusion, the second test was appeared not to be influenced upon liquid back, and it is to expect positive performance by controlling an expansion valve. Therefore, it will be also useful to research for an increase of compressor efficiency Performance improvement of an air conditioner is to reinforce the suction performance of the evaporator and increase the sub-cooling, which make use of the sub-cooling system.

Experimental Study on Noise Reduction of Fan for Automotive Air Conditioner (차량용 공조 팬의 소음 저감에 대한 실험적 연구)

  • Lee, Jin-Kab;Chung, Byung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • This paper is the experimental study to investigate the noise sources location in order to reduce the noise level of line flow fan for the air conditioner in the subway car. The noise of line flow fan is caused by various factors such as the turbulence by air flow, random noise, noise of blade passing frequence(681Hz) and noise due to structural vibration of rotor unbalance(28.4Hz) by motor revolution. By performing the noise reduction on each sound source, the noise level is decreased as much as 5.7dB(A) through the controls of housing guide angle and distance, the configuration changes of flow passage shape and rotor balancing.

Drop Impact Analysis of Outside Cooling Unit Package of System Air-Conditioner and Experimental Verification (시스템 에어컨 실외기 포장품의 낙하충격해석 및 시험적 검증)

  • Kim, Hyung-Seok;Lee, Boo-Yoon;Lee, Sanghoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.111-116
    • /
    • 2018
  • This research examines the drop impact of an external cooling unit package of an air conditioner system. The packaging is composed of a shock-absorbing material, which protects the package contents by absorbing the impact energy and other parts for fixture. Accurate quantification of the impact acceleration experienced by the package contents is necessary to design an effective packaging with minimal volume and sufficient shock absorbing capacity. Explicit time integration was used for the drop impact analyses. A finite element model of the package was constructed, material testing and material model selection were carried out, and sensors for data acquisition were modeled to obtain accurate simulation results. The results were compared with real physical test data. Due to imprecise modeling of the damping, the acceleration and strain values predicted by the simulation were larger than those from physical test. However, the trend of the history data and the peak deceleration value in the direction of impact showed good agreements. Thus, the analysis model and scheme are suitable for the design of an air conditioner cooling unit package.

Development Trends of Refrigerant and Refrigerant Oil for Automotive Air-conditioner (차량용 에어컨에 사용되는 냉매 및 냉동기유의 기술 동향)

  • Lee, Daewoong;Hwang, Seungyong
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.206-214
    • /
    • 2019
  • This study investigates alternative refrigerants and refrigerant oils as well as the tendency of protecting the global environment in view of automobile air-conditioning systems. Since decades, the R12 refrigerant is not used in automobile air-conditioners because of the ozone depletion potential (ODP) problem, and for the last 20 years, the ODP-free R134a refrigerant is leading the new automotive air-conditioning market. However, owing to its high global warming potential (GWP), the R134a refrigerant use in automobile air-conditioning system is also prohibited by law, and alternative refrigerants with a low GWP need to be proposed. Therefore, recently, the application of R1234yf, R152a, or other alternative refrigerants has started worldwide. By contrast, natural refrigerant R744 was introduced in the market several years ago by VDA (Verband Der Automobilindustrie), which is a German association in the automotive industry. This study also deals with refrigerant oils. For a long time, polyalkylene glycol (PAG) oil has been traditionally used with automobile air-conditioners, and polyolester (POE) oil is suitable for HEV, PHEV, and EV air-conditioning systems, where it is used by the electrically driven compressor owing to its excellent electrical insulation properties. Finally, PAG is an excellent lubricant for all the R134a, R152a, R1234yf, and R744 refrigerants, and has the advantage that it can be applied rapidly to alternative refrigerant air-conditioning systems.

A Study on the Clamping Force of an Automotive Air-conditioning Hose according to the Friction Coefficient (마찰계수를 고려한 자동차용 에어컨 호스의 체결력에 관한 연구)

  • Baek, Jae-Kwon;Kim, Byung-Tak
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.3
    • /
    • pp.39-46
    • /
    • 2011
  • The automotive air conditioning hose is used for connecting the components of air conditioner in a vehicle. The hose is usually manufactured by the swaging process to connect the rubber hose with the metal fitting at the end of the hose. In case that the clamping force is small, the refrigerant gas in the hose can leak locally under the severe operating circumstances. The practical test of clamping force is performed by means of the measurement of separation force. In this study, the swaging process of a hose is simulated with the finite element method, to investigate the effect of friction coefficient on the clamping force. The contact condition is used in consideration of real manufacturing process, and the material properties for the Mooney-Rivlin model is obtained by the experimental results. The result interpretations are focused on the contact forces, which is displayed graphically with respect to friction coefficient, on the surfaces between the hose and the metal fittings.

A Study for Faliure Examples Involved Diode, Thermo Sensor and Wiring Short of Electronic Control A/C System in a Vehicle (승용자동차 전자제어 에어컨 장치의 다이오드, 써모센서와 배선단락에 대한 고장사례 고찰)

  • Lee, IL Kwon;Kook, Chang Ho;Ham, Sung Hoon;Lee, Jeong Ho;Moon, Hak Hoon;You, Chang Bae;Hwang, Han Sub;Lim, Chun Moo;Jung, Dong Hwa;Na, Yun Whan
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • The purpose of this paper is to study for a failure examples producing in electronic control air conditioner in vehicle. The first example, it looked for the repetitive fuse cutting phenomenon that the diode using for a surge voltage prevention of inner A/C relay damaged because of no absorbing the surge voltage by short of diode when the A/C is off. The second example, it knew the icing phenomenon of evaporator that the A/C ECU didn't control the A/C because of inner cutting of fin thermo sensor. The third example, it verified the operation trouble phenomenon because of the A/C switch and for sensor burned in flames by short phenom enon when the sheath of the cable has peeled off. Therefore, the driver have to manage the optimism system of a car by thoroughgoing inspection and improvement the failure phenomenon.

Convergent Investigation with Internal Flow Analysis According to the Opening and Closing of Vehicle Window (차량 창문 개폐에 따른 내부에서의 유동 해석으로의 융합적 고찰)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.2
    • /
    • pp.155-160
    • /
    • 2020
  • In this study, the pleasant driving environment of the driver and passenger in the summer was investigated through the internal flow analysis of air due to the opening and closing of the car windows. The conditions on the entrance of the air conditioner with the opening and closing status of vehicle window were applied to the flow analysis by taking into consideration the actual driving environment. The automotive air conditioning outlet, the seat and the inside of car were modeled. As the air flow inside the car was analyzed, the air flow configuration and the temperature distribution were examined. In this analysis, the results were taken in consideration of only the effects of internal air and the opening and closing of window, assuming the interior of the vehicle as insulation. The analysis of each condition shows that these models maintain a pleasant environment. It is seen that this analysis result on the internal flow analysis according to the opening and closing of vehicle window can be applied by converging with the field of design.

Analysis of flow rate of variable displacement compressor ECV in automobile air conditioning control system (자동차 공조장치의 가변압축기 ECV 유량 분석)

  • Jeong, Yeong Jun;Cho, Haeng Muk
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.394-398
    • /
    • 2013
  • At present, using of electromagnetic control valve (ECV) in external variable displacement swash plate type compressor is a common issue. Solenoid operated ECV controls vehicle air conditioning system through a pulse width modulation (PWM) input signal that supplied from an external source. Different port pressure controls the swash plate movement inside the compressor at certain angles that finally determines the refrigerant flow rate to the vehicle compartment for passengers comfort. In this paper, crankcase pressure flow (Pc flow) is calculated with some ECV samples with corresponding to amount of variable supply of current ranges from 0.20Amp to 0.95Amp.