• 제목/요약/키워드: Automation sequence

검색결과 121건 처리시간 0.027초

자동화 지표 계산 및 공장자동화 순서 결정을 위한 방법 (An automaticity indicator computation and a factory automation procedure)

  • 조현보;정기용;이인범;주재구;이주강;전종학
    • 산업공학
    • /
    • 제10권1호
    • /
    • pp.209-222
    • /
    • 1997
  • The paper provides a methodology to obtain the automaticity indicator of a factory and the sequence of enabling technologies of factory automation. The automaticity indicator is the measure of the current automation status of a factory and can be used as a crucial criteria for the future automation schedule and investment. Although most industries have their own computation methods which usually consider the number of workers in the shop floor, this research covers five evaluation items of automation, such as, production facility, material transfer system, inspection and test system, information system, and flexibility. The detailed evaluation models are developed for each item. Automation sequencing prioritizes the enabling technologies of factory automation on the basis of several criteria which consist of two phases. The first phase includes the automation indicator and the second phase includes six sub-criteria such as production rate, quality, number of workers, capital investment, development duration, development difficulty. For this evaluation, AHP(Analytical Hierarchy Process) is introduced to prevent the decision maker's subject intention. As results of the automaticity indicator and automation sequence, the manager can save time and cost in building constructive and transparent automation plans.

  • PDF

순로정보 데이터베이스 프로토타입 개발 (Development of DSI(Delivery Sequence Information) Database Prototype)

  • 김용식;이홍철;강정윤;남윤석
    • 산업공학
    • /
    • 제14권3호
    • /
    • pp.247-254
    • /
    • 2001
  • As current postal automation is limited to dispatch and arrival sorting, delivery sequence sorting is performed manually by each postman. It not only acts as a bottleneck process in the overall mailing process but is expensive operation. To cope with this problem effectively, delivery sequence sorting automation is required. The important components of delivery sequence sorting automation system are sequence sorter and Hangul OCR which function is to extract the address of delivery point. DSI database will be interfaced to both Hangul OCR and sequence sorter for finding the accurate delivery sequence number and stacker number. The objectives of this research are to develop DSI(Delivery Sequence Information) database prototype and client application for managing information effectively. For database requirements collection and analysis, we draw all possible sorting plans, and apply the AHP(Analytic Hierarchy Process) method to determine the optimal one. And then, we design DSI database schema based on the optimal one and implement it using Oracle RDBMS. In addition, as address information in DIS database consist of hierarchical structure which has its correspondence sequence number, so it is important to reorganize sequence information accurately when address information is inserted, deleted or updated. To increase delivery accuracy, we reflect this point in writing application.

  • PDF

보일러 플랜트의 Start-Up 운전자동화를 위한 모델링 (Modeling for the Automation of Start-up Operation in Boiler Plant)

  • 윤영진;황규석
    • 한국안전학회지
    • /
    • 제12권1호
    • /
    • pp.60-70
    • /
    • 1997
  • Since, human error is a major factor contributing to disaster during start-up of operation in Boiler plant. it is necessary to develop an automation system which prevent mode of operation that are known to be dangerous and to bring a loss of energy. The aim of this study is to suggest a model for the computer-aided synthesis of operation sequence as a part of automation system for start-up operation. Synthesis is accomplished by the formation of a hierarchical network of goals which decide sequence of operations. Hierarchical Network is formed by using method which upper goals ( i.e. upper operation al situation) are classified by the function of themselves into lower goals (i.e. lower operational situation). Knowledge for deciding operation sequence is generated by putting In order the knowledge of hazard operation and energy management.

  • PDF

다양한 도메인 기능을 갖는 PAC 시스템 개발 (Development of Programmable Automation Controllers (PACs) having Multi-Domain Functionality)

  • 김경돈;이강주;김형내;오진식;김찬봉
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.250-253
    • /
    • 2005
  • A Programmable Automation Controller (PAC) has been developed by Turbotek Co., Ltd. The developed system has multi-domain functionality-including sequence control, motion control and HMI- on a single platform. The PAC also has a common development platform for the design and integration of multi-domain automated systems. Since hardware of the developed system has modular architectures, performance and specification of the controller are determined by combination of specific modules. The developed system employs de facto standards such as OPC interface that allow users to easily exchange data as part of networked multi-vendor systems.

  • PDF

A New Strategy for Service Restoration and Switching Sequence Determination in Distribution Automation Systems

  • Lee, Seung-Jae
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권1호
    • /
    • pp.51-57
    • /
    • 1998
  • As DAS becomes a common practice, various operational tools are needed. This paper proposes the new restoration strategy considering the coordination of the protective devices and the generalized method for determining the switching sequence. The effectiveness of the proposed method has been tested on the various real systems.

  • PDF

New Strategy for Eliminating Zero-sequence Circulating Current between Parallel Operating Three-level NPC Voltage Source Inverters

  • Li, Kai;Dong, Zhenhua;Wang, Xiaodong;Peng, Chao;Deng, Fujin;Guerrero, Josep;Vasquez, Juan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.70-80
    • /
    • 2018
  • A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter.

Image Sequence Stabilization Scheme Using FIR Filtering

  • Kim, Pyung-Soo
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권4호
    • /
    • pp.515-519
    • /
    • 2003
  • This paper proposes a new image sequence stabilization (ISS) scheme based on filtering of absolute frame positions. The proposed ISS scheme removes undesired motion effects in real-time, while preserving desired gross camera displacements. The well-known finite impulse response (FIR) filter is adopted for filtering. The proposed ISS scheme provides a filtered position and velocity with fine inherent properties. It is demonstrated that the filtered position is not affected by the constant velocity. It is also shown that the filtered velocity is separated from the position. Via numerical simulations, the performance of the proposed scheme is shown to be superior to the existing Kalman filtering scheme.

Fatigue wind load spectrum construction based on integration of turbulent wind model and measured data for long-span metal roof

  • Liman Yang;Cong Ye;Xu Yang;Xueyao Yang;Jian-ge Kou
    • Wind and Structures
    • /
    • 제36권2호
    • /
    • pp.121-131
    • /
    • 2023
  • Aiming at the problem that fatigue characteristics of metal roof rely on local physical tests and lacks the cyclic load sequence matching with regional climate, this paper proposed a method of constructing the fatigue load spectrum based on integration of wind load model, measured data of long-span metal roof and climate statistical data. According to the turbulence characteristics of wind, the wind load model is established from the aspects of turbulence intensity, power spectral density and wind pressure coefficient. Considering the influence of roof configuration on wind pressure distribution, the parameters are modified through fusing the measured data with least squares method to approximate the actual wind pressure load of the roof system. Furthermore, with regards to the wind climate characteristics of building location, Weibull model is adopted to analyze the regional meteorological data to obtain the probability density distribution of wind velocity used for calculating wind load, so as to establish the cyclic wind load sequence with the attributes of regional climate and building configuration. Finally, taking a workshop's metal roof as an example, the wind load spectrum is constructed according to this method, and the fatigue simulation and residual life prediction are implemented based on the experimental data. The forecasting result is lightly higher than the design standards, consistent with general principles of its conservative safety design scale, which shows that the presented method is validated for the fatigue characteristics study and health assessment of metal roof.

Intrusion Detection Scheme Using Traffic Prediction for Wireless Industrial Networks

  • Wei, Min;Kim, Kee-Cheon
    • Journal of Communications and Networks
    • /
    • 제14권3호
    • /
    • pp.310-318
    • /
    • 2012
  • Detecting intrusion attacks accurately and rapidly in wireless networks is one of the most challenging security problems. Intrusion attacks of various types can be detected by the change in traffic flow that they induce. Wireless industrial networks based on the wireless networks for industrial automation-process automation (WIA-PA) standard use a superframe to schedule network communications. We propose an intrusion detection system for WIA-PA networks. After modeling and analyzing traffic flow data by time-sequence techniques, we propose a data traffic prediction model based on autoregressive moving average (ARMA) using the time series data. The model can quickly and precisely predict network traffic. We initialized the model with data traffic measurements taken by a 16-channel analyzer. Test results show that our scheme can effectively detect intrusion attacks, improve the overall network performance, and prolong the network lifetime.

홈 자동화를 위한 다기능 스위치 설계 (Design of Multi function switch for Home Automation)

  • 권상우;김현경;김백기;곽윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.196-200
    • /
    • 2003
  • 본 논문에서는 마이크로 컨트롤러를 사용한 다기능 스위치에 대하여 설명한다. 21세기 정보화 시대에 발 맞추어 산업 현장에서는 공장 자동화를 더불어 가정에서는 흠 자동화 시스템이 확산되고 있다. 공장 자동화 및 홈 자동화를 구현하기 위해서 컴퓨터의 사용은 불가피하다. 따라서 사용자와 컴퓨터간 인터페이스 기술과 컴퓨터와 제품간 인터페이스 기술을 요하게 된다. 본 논문의 다기능 스위치는 자동화 시스템 구현에 필요한 인터페이스를 제공해 준다. 또한 마이크로 컨트롤러가 탑재되어 있기 때문에 독립적으로 사용할 수 있다. 따라서 가정에서 간단한 홈 자동화를 구현 할 수 있으며 산업현장에서는 간단한 시퀀스 제어를 이용한 자동화 시스템에 사용될 수 있다. 또한 각종 시스템에 복합적으로 또는 독립적으로 사용이 가능하다.

  • PDF