• Title/Summary/Keyword: Automatic water control system

Search Result 195, Processing Time 0.028 seconds

Improvement of treatment efficiency for sanitary treatment facilities by process modifications (분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구)

  • Lee, Chan Won;Kim, Seung Hyeon;Kim, Chang Su;Mun, Seong Won;Jeon, Hong Pyo;Yun, Jong Seop
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

The study on the estimation of heat transfer coefficient through the counterflow concentric tube using refrigerant and moisture air (냉매와 습공기가 교차하는 2중관에서 전열계수 예측을 위한 연구)

  • 조권희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.5
    • /
    • pp.687-694
    • /
    • 1999
  • This study was conducted to develop new drying process for automatic control and marine engi-neering system. Air-water tests were carried out to investigate dryer performance. The dispersed flow in he dryer test apparatuses was also simulated by using a numerical code which solves the Dittus-Boelter equation for continuous liquid phase and the Reynolds equation of droplet motion for continuous liquid phase and the Reynolds equation of droplet motion for dispersed phase to predict droplet removal efficiency. Proper conditions for dehumidification were optimized by response ambient conditions. When the selected indexes were constrained in the range of 85-98% moisture content above $15^{\circ}$ and more than mass flow rates of moist air 750kg/h. The numerical results were compared with the experimental data pertaining to the removal effi-ciency at chamber stage and overall pressure drop along concentric tubes Good agreement was obtained as for the efficiency while relatively poor agreement was obtained for the relative humidity. The results also showed that the efficiency depended strongly on the relative humidity at the inlet condition which indicated the importance of estimating the heat exchanger length. Effects of some design parameters in both removal efficiency and breakthrough onset condition are discussed.

  • PDF

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

Effects of Spray Times and Ventilation Method on the Seedling Growth of Fruit Vegetables (관수회수 및 송풍처리가 과채류의 묘 생장에 미치는 영향)

  • Kim Chang-Soo;Min Byeong-Ro;Kim Wong;Kim Dong-Woo;Seo Kwang-Wook;Lee Beom-Seon;Lee Dae-Weon
    • Journal of Bio-Environment Control
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2005
  • A multipurpose operating system was developed to adjust both spray times and ventilation method without a configuration of the moving path and the type of the greenhouse. The multipurpose working system proved to be a reliable system for testing the growth quality of the fruit vegetables in the greenhouse. The results are as follows. The first leaf, diameter of a stem, leaf area, and average stem diameter in the Cucumber seedling growth were repressed by high-speed ventilation, but was not repressed by spray times. The first leaf in the Tomato seedling growth was repressed as ventilation velocity was high, but the average stem diameter was not repressed. While the Tomato was given water three times a day, the diameter of a stem and the leaf area were increased as ventilation speed became higher. However, those were different other factors. The Tomato leaf area was larger when given water twice a day than that in hand spray, but showed no difference with ventilation speed. The first leaf, the diameter of a stem and the leaf area of a Red pepper were lower in automatic spraying with ventilation than those in hand spray.

Design and Implementation of Non-contact IoT Ringer Replacement Automatic Notification System (비접촉 IoT 링거 교체 자동 알림 시스템 설계 및 구현)

  • Lee, Hyo-Seung;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1405-1410
    • /
    • 2018
  • The Ringer's Solution used in medical institutions is one of the injections helpful for recovering the body condition from fever or dehydration by supplying the water to the body. The medical staffs frequently check the amount of Ringer's Solution prescribed for the relevant patient to check the time for replacing the Ringer's Solution. However, currently, many nurses experience the excessive workload because of the insufficient workforce and lots of workload assigned to each of the nurses; so the they cannot provide the high-quality medical services to patients and guardians. In order to solve this problem, this thesis designed and realized the Ringer's Solution replacement time control system through the non-contacting sensor, IoT device using WiFi, and OCS interlock. Thus, this study is expected to be able to efficiently operate the Ringer's Solution replacement work and also to provide the high-quality medical service to patients and guardians by automatically notifying the timing of Ringer's Solution replacement to medical staffs, and omitting the inefficient intermediate step in the past.

Characteristics of Non-Point Pollution from Road Surface Runoff

  • Lee, Chun-Sik;Jang, Seong-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.665-670
    • /
    • 2010
  • Pollutants from urban pavement consists various kinds of substances which are originated from dry deposition, a grind out tire, corrosive action of rain to pavement and facilities and raw materials of the road etc.. These are major pollutants of urban NPS (Non-point source) during rainfall period. However there is not enough information to control such pollutants for appropriate management of natural water quality. In this study of transportation areas, three monitoring stations were set up at trunk road, urban highway and national road in Gyeongnam province. Runoff flow rate was measured at every 15minutes by automatic flow meters installed at the end of storm sewer pipe within the road catchment area for water quality analysis. Data was collected every 15 minutes for initial two hours of rainfall. Additional samples were collected 1-4 hours interval till the end of rainfall. The monitoring parameters were $COD_{Mn}$, SS, T-N & T-P and heavy metals. The average EMCs of TSS and $COD_{Mn}$ were 62.0 mg/L and 24.2 mg/L on the city trunk road, which were higher than those of urban highway and national road, indicating higher pollutant loads due to activities in the city downtown area beside the vehicle. On the other hand, the average EMC of T-N and T-P were in the range of 2.67-3.23 mg/L and 0.19-3.21 mg/L for all the sampling sites. Heavy metals from the roads were mainly Fe, Zn, Cu and Mn, showing variable EMCs by the type of road. From the TSS wash-off analysis in terms of FF(first flush) index, first flush phenomenon was clearly observed in the trunk road(FF : 0.89-1.43). However, such mass delivery behavior was not apparently shown in urban highway(FF : 0.90-1.11) and national road(FF : 0.81-1.41).

Laver(Kim) Thickness Measurement and Control System Design (해태(김)두께측정 및 조절 장치 설계)

  • Lee, Bae-Kyu;Choi, Young-Il;Kim, Jung-Hwa
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.226-233
    • /
    • 2013
  • In this study, In Laver's automatic drying device, laver thickness measurement and control devices that are associated with. Disconnect the water and steam, after put a certain amount of the mixture(water and laver) in the mold. In process, Laver of the size and thickness (weight) to determine, constant light source to detect and image LED Lamp occur Vision Sensor (Camera) prepare, then the values of these state of the image is transmitted in real time embedded computers. Built-in measurement and control with the purpose of the application of each of the channels separately provided measurements are displayed on a monitor, And servo signals sent to each of the channels and it become so set function should be. In this paper, the laver drying device, prior to the laver thickness measurement and control devices that rely on the experience of existing workers directly laver manually adjust the thickness of the lever, but the lever by each channel relative to the actuator by installing was to improve the quality. In addition, The effect of productivity gains and labor savings are.

Development of Automatic Measurement and Control Method based on Single Chip Microcomputer for Tackjoo Fermentation (Single Chip Microcomputer를 이용한 탁주발효(濁酒醱酵)의 자동계측(自動計測)과 제어방법(制御方法)의 개발(開發))

  • Kim, Kyung-Man;Chun, Jae-Kun
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.391-394
    • /
    • 1993
  • For the automation of Tackjoo fermentation, a sensor measurable gas production during brewing and a controller were built. The performance tests were carried out at 10 litter Tackjoo fermentor, The sensor was consisted of a transparent acryl cell for bubble formation and photo-interrupter for the detection of bubbles of 0.018ml size. The fermentation controller was fabricated with a single chip microcomputer (MC68705R3) and provided with both the monitoring module of temperature measurement and the valve controling device for the cooling water circulation in coil type heat exchanger. The operation programs were developed and systemized in ROM. With this computer system, the gas production amount and rate were acquired during the Tackjoo fermentation. The fermentation curve based on the gas production rate showed a good agreement with that of alcohol concentration. The maximum rate of gas production was found after 24 hr at $30^{\circ}C$. The correlation equation between the gas production and alcohol concentration was established and used as the control algorithm of the fermentation.

  • PDF

An experimental study on the operation mode of rapid flooding protection system in tunnel (축소모형실험을 통한 터널 내 급속침수 차폐자동화 시스템 작동형태에 대한 연구)

  • Kim, Yeon-Deok;Kong, Min-Teak;Hwang, Beoung-Hyeon;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1147-1159
    • /
    • 2018
  • This study focuses on the verification of a rapid protection automation system using an inflatable structure. The inflatable structure is an automatic rapid protection system against human and material damage when the subsea tunnel is flooded. Especially, it is essential for construction and operation of subsea tunnels. In this study, we have experimentally verified the rapid protection automation system using the inflatable structure designed for this problem. In order to verify this, a model tunnel with a 40: 1 reduction ratio was constructed, and air pressure of 0.1 bar and 0.15 bar was injected to divide the tunnel according to the expansion rate at 10 sec and 20 sec. According to the results of the study, the protection efficiency was better at 0.15 bar than 0.1 bar when the expansion structure was expanded, and the protection efficiency and influent control efficiency were different according to the pneumatic injection time of the inflating structure. As a result of this study, it was found that the higher the internal air pressure of the inflated structure and the faster the inflation of rate, the more effectively the inflated structure was inflated. As a result of this study, it is necessary to further study the wedge type structure which is useful for the storage method of expansion structure, shape and expansion derivative, inhibition of expansion structure during protection and control of inflow water.

A Development of Automation System and a Way to use Solar Energy System Efficiently in Greenhouse(1) - Study on temperature variation of soil heating in greenhouse - (시설원예용 태양열 시스템의 효율적 이용과 자동화 장치개발(1) - 시설재배시 지중가온의 온도변화 연구 -)

  • 김진현;김철수;명병수;최중섭;구건효;김태욱
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1998
  • The greenhouse temperature controls in general have been managed by the above-ground part environment, But the temperature of root zone was known very important factor for the 9rofth and the yield of vegetables in greenhouse. The purpose of this study is to develop a good method for cultivation using solar energy which can apply warming soil and to develop the greenhouse soil temperature automatic control system. Followings are summary of this study:1 When the greenhouse inner temperature changes were about 24$^{\circ}C$ during a day in October, the temperature of non-warmed soil was differenced 6$^{\circ}C$ in the depth 10cm and 3$^{\circ}C$ in the depth 20cm. 2. When water supply temperature was kept at 40, 50 and 6$0^{\circ}C$, the lowest soil temperature in the depth of 10cm is 2$0^{\circ}C$ and that of 20cm was 23$^{\circ}C$. and when the water supply temperature was over 4$0^{\circ}C$, the space heating temperature did not affect the temperature variation of soil. 3. In comparison with conditions of the warmed and non-warmed soil, when the water supply temperature is 28$^{\circ}C$, soil temperatures had the high temperature of 4$0^{\circ}C$~7$^{\circ}C$ in the depth of 10cm to 20 cm. 4. The line of boundary area was appeared in the depth of 15~20cm, 13~19cm and 12~17cm. when the water supply temperature was 4$0^{\circ}C$, 5$0^{\circ}C$ and 6$0^{\circ}C$. 5. When th inner greenhouse air temperature is maintained over 11$^{\circ}C$ and the water supply temperature is supported 28$^{\circ}C$, the lowest temperature is kept up over 2$0^{\circ}C$.

  • PDF