• 제목/요약/키워드: Automatic temperature control system

검색결과 207건 처리시간 0.041초

Smart Dairy Management System Development Using Biometric/Environmental Sensors and Farm Control Gateway (생체 환경 정보 센싱 모듈 및 농장 제어 게이트웨이를 이용한 스마트 낙농 관리 시스템 개발)

  • Park, Yongju;Moon, Jun
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • 제11권1호
    • /
    • pp.15-20
    • /
    • 2016
  • Recently, the u-IT applications for plants and livestock become larger and control of livestock farm environment has been used important in the field of industry. We implemented wireless sensor networks and farm environment automatic control system for applying to the breeding barn environment by calculating the THI index. First, we gathered environmental information like livestock object temperature, heart rate and momentum. And we also collected the farm environment data including temperature, humidity and illuminance for calculating the THI index. Then we provide accurate control action roof open and electric fan in of intelligent farm to keep the best state automatically by using collected data. We believed this technology can improve industrial competitiveness through the u-IT based smart integrated management system introduction for industry aversion and dairy industries labor shortages due to hard work and old ageing.

Optimal Driving of Photo-Sensor for Control of A Mixed Environment (복합환경제어를 위한 광량 센서장치의 최적구동)

  • Kim, Jong-Man;Kim, Won-Sop;Kim, Hyung-Suk
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2110-2111
    • /
    • 2011
  • Optimal Driving of Photo-Sensor for Control of a Mixed Environment was realized. The control system was carried out to investigate into the characteristics of Real time control of temperature and humidity at sprouts cutivators. Especially, for led's control for the cultivation of sprouts we have composed a Combined Automatic Control System possible for the control of temperature and humidity at the same time. The applied Photo-Sensor measurement are blue, green, red, white, yellow leds. And we had also designed the Web Programming for the automatic control about sprouts plants.

  • PDF

Simulation Study for Control Strategies of Indoor Air Temperature in Floor Radiant Heating System (바닥 복사난방 시스템의 실내온도 제어방안에 관한 시뮬레이션 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • 제12권4호
    • /
    • pp.21-26
    • /
    • 2016
  • In this study, the control strategies of indoor air temperature in floor radiant heating system were researched by computer simulation. The temperature difference based time control method using the difference of indoor set temperature and indoor temperature is compared with the existing On-Off control one for heating control performances. As a result, the temperature difference based time control method shows better thermal environmental characteristics in case of selected operational conditions in comparison with existing control one.

Thermal Inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in Liquid Cultures During Microwave Radiation (Microwave 조사에 의한 Salmonella enteritidis, Salmonella typhimurium 과 E. coli의 불활성에 관한 연구)

  • 이조윤;이강욱;배형철;김종우
    • Food Science of Animal Resources
    • /
    • 제18권3호
    • /
    • pp.269-275
    • /
    • 1998
  • The purpose of this study was to determine the thermal inactivation of Salmonella enteritidis, Salmonella typhimurium and E. coli O111 in liquid cultures treated with microwave energy. Furthermore, this study was to introduce new methodologies for studying nonthermal microwave effects on microorganisms, using controlled microwave energy and specially designed apparatuses. For the automatic temperature control during microwave heating, the real time data acquisition and computation system is designed with BASIC routine. The automatic temperature control system used in the experiments perform relatively stable control at the experiment temperature of 45, 50, 55 60$^{\circ}C$ and 65$^{\circ}C$ for 30 minutes. The effects of microwave heating on liquid cultures was compared with that of conventional heating, still reduces effectively the number of pathogenic bacteria in liquid cultures. While no particular differences between microwave heating and conventional heating was observed in the activation of E. coli at 45$^{\circ}C$ test, the activation of Sal. enteritidis and Sal. typhimurium was slightly reduced during the microwave treatments.

  • PDF

A Study on the Characteristics of Automatic Flatness Control System for Cold Rolling (냉각압연 가공용 자동 형상제어장치의 특성에 관한 연구)

  • Kim, Moon-Kyung;Jeon, Eon-Chan;Kim, Soon-Kyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제20권9호
    • /
    • pp.2901-2907
    • /
    • 1996
  • Flatness of cold rolled strip is vital to the quality of the product and productivity of the mill. Therefore, in recent year requirement for flatness control in strip rolling have become increasingly severe. The necessity for more accurate automatic gauge control and automatic flatness control(AFC) has increased by customer's requirement for cold rolled steel sheets with thinner gauge and better flatness quality. In this paper, the performance and functions of AFC system installed on the 4 hi-reversing mill has been investigated under actual conditions. The test results are as follows : The more strip thickness is thick, the smaller the I-value. The I-value is a strain measured by stressometer. Complex distributions of strip tension are controlled to remove not only a quarter buckle but also a simple center wave and edge wave. The defects caused by poor flatness have been drastically decreased. And a proper coolant temperature for work roll cooling system on the AFC system is about $50~55^{\circ}C$.

The Development Measuring System of Temperature Effect to Produce Electric Power of Solar Cell

  • Sadmai, Ong-art
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.104-113
    • /
    • 2015
  • This paper focuses on a temperature effects on a PV panel which has been installed in Thailand. The main objective is cleaning PV panels and reduce temperature of PV panel by water injects from waterway and experimental results of PV power what it is difference. This project is designed by PLC control system which water injects and control PV temperature, In addition, this project consists of hardware and software such as water pump, water injection and PLC control has been automatically and it can be control system manually. The automatic control system is working when PV temperature rises up over 45 degree Celsius after that the pumping machine would inject water to the surface of PV panels and it must be stop when the PV panel temperature comes down less than 45 degree Celsius. The result of actual experimental found that the control system has been done correctly under specify condition. The experimental has been shown electrical data before and after water injects on PV system found that the electrical power a bit increases and The energy has been taken from PV panel less than energy consumption equipment of control system which taken to operate the water injecting system.

A Study on the Hydrothermal Synthesis of Clay Mineral (III) -Scale up Test for the Hydrothermal Synthesis of Clay Mineral from Anorthite and the Automatic Control System Development- (수열반응에 의한 인공점토의 합성연구(III) -경남 산청산 회장석으로부터 교반식 수열 반응장치에 의한 인공점토의 대량생산 실험 및 수열반응의 자동 조절 제어장치 개발-)

  • ;;Kunio Kimura
    • Journal of the Korean Ceramic Society
    • /
    • 제32권7호
    • /
    • pp.777-782
    • /
    • 1995
  • The scale up production test for the hydrothermal synthesis of clay mineral from the anorthite, which is distributed in San Chung-District of Korea and called as the ground rock for halloysite-kaolin, has been investigated by using the gaitator type reactor. The automatic control system has been developed and applied for the more effective producibility and the reduction in the defect of this intermittent batch processing property, and finally for the feasibility of this system in actual use. It was observed that this agitator type reactor can reduce the synthesis reaction tme from 5 days to 3 days, only with the condition of 20rpm. The automatic control system could regulate the vessel temperature and pressure precisely at an optimum condition during the treatment. Therefore, from these test results the application-possibility for this system was found to be feasible in actual use.

  • PDF

The improvement for steam temperature control at Boryung bituminous coal-fired drum boiler type thermal power plant (유연탄연소 드럼타입 보일러를 채택한 발전프랜트의 효율적 온도제어에 관한 연구)

  • 류홍우;황재호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.693-696
    • /
    • 1988
  • This paper is investigated on the improvement for steam temperature control at Boryung coal-fired drum boiler type thermal power plant. The steam temperatur control has been mainly operated by the feedback controllers. Automatic controllers are bounded and difficult. Because boiler system is nonlinear and the system time delay is very large. Optimal regulators including predictive feedforward and differentiate control are synthesized and some improved output results are presented.

  • PDF

Automatic system to the Sensing of Temperature and Weight and the Temperature Control in Food Drying (식품 건조공정중 온도, 무게 변화의 자동계측 및 온도제어시스템)

  • Kim, Dong-Woo;Cho, Kwang-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • 제18권1호
    • /
    • pp.29-33
    • /
    • 1989
  • As one of the application of microcomputer for data acquisition and temperature control of food drying process, these studies designed and built 'the interface system, measuring sensors of weight and temperature, temperature control system'. The basic and assembly language was used to operating these system. These system measured successfully the variables such as weight and temperature during food drying, and controlled Automatically the drying temperature.

  • PDF

Development of Automatic Nutrient-Solution Control System Using a Low -Cost and Precise Liquid Metering Device (액제 정밀계량장치를 이용한 액제 자동조제 시스템개발)

  • 류관희;홍순호;이규철;이정훈;황호준
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 한국농업기계학회 1997년도 하계 학술대회 논문집
    • /
    • pp.89-98
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution control system for small-scale growers. The nutrient-solution control system consisted of a low-cost and precise metering device and a personal computer. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-soIution. The performance of the nutrient-solution control system was evaluated through the control of EC and pH while compared with those of commercial nutrient-solution control system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. An automatic nutrient-solution control system based on a low-cost and precise metering device was developed. 2. The developed system controlled EC and pH within $\pm$0.05 mS/cm and $\pm$0.2 pH full scale error respectively at $24^{/circ}C$. 3. When using the commercial system, the controlled values of EC and pH of the 500l of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at $22^{/circ}C$. 4. The developed nutrient-solution control system showed $\pm$0.05 mS/cm of deviation from the setting EC value over the experimental cultivation period. 5. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF