• 제목/요약/키워드: Automatic switch

검색결과 119건 처리시간 0.028초

전력변환차단기의 트리거 기구 최적화 (Optimization ova Mechanism for Power Transfer Breakers)

  • 조두현;김권희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.735-739
    • /
    • 2002
  • PTB(Power Transfer Breaker) is a device which incorporate the functions of ACB(Air Circuit Breaker) and ATS(Automatic Transfer Switch). ACB is a circuit breaker against overload and ATS is a switching device to transfer the load between two electric power sources. An existing PTB design based upon the 5 bar & cam mechanism has been regarded to be too complex and thus a simpler 4 bar mechanism with trigger lock is proposed. Experimentation and optimization of the trigger lock is presented.

  • PDF

PLC를 이용한 자동 연마석 평면 연삭기 개발 (Development of automatic surface grinder using PLC)

  • 주해호;이재원;박현제
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.71-74
    • /
    • 1992
  • This paper describes the automation of the surface grinder for a grinding wheel by application of programmable logic controller(PLC) with a position sensor, and a limit switch. The control system is designed to provide feeding a workpiece on the turn table and pressing it by the upper disk automatically. In this development the automation of checking the thickness of a grinding wheel is most important. In order to measure the relative displacement, the proximity sensors were employed and the sensitivities of the sensors were investicated and discussed the superiority. It has been shown by model experiment that the automation system of the surface grinder is performed satisfactory.

  • PDF

농업 신기술 도입여부에 영향을 미치는 요인분석 -참외 보온덮개 자동개폐기를 중심으로- (Effect Analysis of Introduction of New Agricultural Technology - Case Study Base on Automatic Switch for Heat Insulating Covering -)

  • 최돈우;연일권;도한우;임청룡
    • 농촌계획
    • /
    • 제18권2호
    • /
    • pp.39-45
    • /
    • 2012
  • The objective of this study was to analyze the determinant factors in the new agricultural technology acceptance targeted to the automatic switchgear for heat-retaining mulching used on the oriental melons farms. The probit and the logit models were estimated using survey data. The result indicated that the level of income, innovativeness, and reliability are important factors of the new agricultural technology acceptance. Therefore, it is considered the level of income, innovativeness, and reliability in advance to extend the new agricultural technology quickly.

Development of High Efficiency Boost DC/DC Converter For EV

  • Song, Sung-Geon;Lee, Sang-Hun;Song, Hyun-Jig;Park, Seong-Mi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.415-421
    • /
    • 2014
  • In this paper, reactorless high efficiency boost DC/DC converter for EV is proposed. In proposed converter, improves efficiency because decrease power loss when the switches are turned on/off using zero current switching (ZCS) at all switch of primary full bridge. By replacing reactance ingredients of L-C resonance circuit for ZCS with leakage inductance ingredients of high frequency transformer, it reduces system size and expense because of not add special reactor. For validity verification of proposed converter, in the paper implements simulation using PSIM and perform experiment by making 5KW DC/DC converter. In experimental results, efficiency of proposed converter conformed superiority.

IBM-PC를 이용한 다점 계측 자동화 시스템 (Automatic multipoint measuring system using IBM-PC)

  • 정상용;양원영
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.541-546
    • /
    • 1989
  • In case there are many points to be measured in the field, conventional measuring system requires a lot of manpower and is liable to miss applying the timely countermeasure because processing and analyzing the data obtained also takes much time. Therefore the purpose of this paper is focused on removing the above defects by introducing automatic multi-point measuring system by use of IBM-PC or the compatibles easily at hand nowadays. Principal components of the system is composed of control box, A/D converter. 32 channel 4 wire switch boxes and strain amplifier. An application software was developed for multi point measurement system in order to efficiently evaluate the stability of the structures such as retaining walls.

  • PDF

가정용 비상 전원 절체 모듈 개발 (A Development of Energency Power Automatic Transfer Module in home)

  • 주남규;김관영;김남호;이종명
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.321-323
    • /
    • 2009
  • When power failure occurs at multi-housing complex, auxiliary generator or emergency generator starts to provide power to households. This power is connected to emergency power ELB(Earth Leakage Breaker) at home distribution panel board and supplies power only for emergency light in living room but for heating system, refrigerator and other inevitable apparatuses that are in need of uninterruptible power. Since those domestic appliance are fed from common power line, they are inoperable during power failure. Our research is to resolve this problem by developing compatible relay-drive common/emergency-power ATS (automatic transfer switch) for home distribution panel board. In case of power failure, it transfers automatically and commences to provide power from emergency generator. Through this, Consumers can reach satisfaction where common power loads operate without any problem under both ordinary and power failure condition.

  • PDF

자동 탭 절환 내장형 주상변압기 개발에 관한 연구 (Development Pole Transformer with Automatic Tap Changer)

  • 남궁원;이성우;장문종
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.108-113
    • /
    • 2013
  • Change of supply voltage, customer load, output of distributed generation, etc cause voltage change in distribution system. OLTC and SVR are usually used to supply normal voltage at customer. But usage of these devices is inefficient and uneconomical in certain circumstances. To solve this problem, new pole transformer which has automatic tap changer is developed. The transformer changes tap when voltage changes. And it has latch switch and reactor for supplying power without outage. To verify normal operation of tap changer, test is conducted. SVR and 50kVA load is used for test.

CAN통신 기반의 상용차용 공압구동형 세미오토 클러치 개발 (Development of a Pneumatic Semi-Automatic Clutch for Commercial Vehicles based on the CAN Communication)

  • 김성진;이동근;안경환;이성철
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4742-4748
    • /
    • 2014
  • 전북 익산시 R회사에서 기 개발된 세미오토 클러치는 수동클러치 차량의 기어 변속시 클러치 페달을 밟아야하는 불편함을 해소하고자 만들어진 장치로써 클러치 페달을 밟지 않고, 운전자가 기어봉에 위치한 스위치 조작만으로도 클러치 동작을 제어할 수 있다. 차량의 변속과정에서 클러치 동작을 제어하기 위해 센서를 설치하여 차량정보를 수집하여 제어하였다. 그러나, 센서 기반의 제어기는 열악한 운전조건에서 고장 원인이 되고 있으며, 차량에 설치하고 보수하는 과정에서 시간소요가 과다하여 많은 불편을 가지고 있었다. 이를 위해 본 연구에서는 차량의 ECU와 CAN통신을 통해 차량의 주행정보를 수집하여 제어하고, 공압 액추에이터로 클러치를 동작시키는 세미오토 클러치를 개발하였다. 개발된 공압 액추에이터의 정상적인 동작을 위해서는 최소 3bar이상이 요구되었다.

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(II) -자동화 시스템의 종합제어기 개발- (Fundamental Studies for the Automatic Control System in the Greenhouse Using Microcomputer(II) -A Development of a Controller for an Automatic Control System-)

  • 김진현;김철수
    • Journal of Biosystems Engineering
    • /
    • 제20권1호
    • /
    • pp.73-86
    • /
    • 1995
  • The automatic control system in the greenhouse have to be developed to the direction of considering various factors the variables such as condition of the cultivation and greenhouse, the properties and types of products. Therefore, it is more important to set up variables appropriately than the problems of automatic control system itself, and the automatic control system which satisfy these problems should be simplified in the aspect of operation. In addition, even the individual automations are not perfect yet, so more studies are required for the development of comprehensive automatic system in korea. This study was carried out to automatize environment control systems for greenhouse, especially from most intensive labor requiring parts such as watering, irrigating liquefied fertilizer, spraying chemicals, mixing and ventilation system, etc. The results are summarized as follows. 1. Control type tensiometer was expected to be desirable in the automation of watering system, therefore, a new tensiometer was designed and developed through this study. 2. The chemical spraying system developed through this study was found to be excellent in the aspect of operation. 3. When pulse type water discharge meter was used in the mixing of liquefied fertilizer and chemical solution, the error of mixing were range $\pm$0.1~0.15%. 4. The water level switch of electrod type used for controlling water level was found to be affective in both control performance and operation cost. 5. The water and level control system can be omitted if each tank size are standardized in accordance with greenhouse size, therefore, the installation cost might be significantly reduced. 6. The developed general controller was excellent in hardware parts, but still remained to be improved in software parts.

  • PDF

직렬 변압기를 이용한 고정밀 자동전압조절기 (High precision Automatic Voltage Regulator by using series transformer)

  • 장뢰;이화춘;정태욱;남해곤;남순열;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF