• 제목/요약/키워드: Automatic switch

검색결과 119건 처리시간 0.025초

신뢰도 비용 최소화를 위한 개폐기의 최적 자동화율 도출에 관한 연구 (Study of Drawing Optimum Switch Automation Rate to Minimize Reliability Cost)

  • 채희석;강병욱;김진석;문종필;김재철
    • 전기학회논문지P
    • /
    • 제64권4호
    • /
    • pp.297-302
    • /
    • 2015
  • Replacing a manual switch installed in a feeder for a distribution system with an automatic one increases the reliability of the electric power system. This is because the automatic switch can shorten the duration of a fault the customer experiences by splitting the faulty section faster than the manual one does. However, improving the reliability of the distribution system may increase investment costs. Here, the investment costs include automatic switch cost, replacement work cost and labor cost. For this reason, importance should be attached to the proper balance between the increase of the investment costs and the improvement of the reliability of the distribution system. This article analyzed reliability index and economics when manual switches installed in a feeder (RBTS Bus2 model) was replaced by automatic ones. In addition, it attempted to draw the optimum rate of automation of manual switches by automatic ones using the GRG optimization method, considering the current economic requirements.

압력스위치 성능시험보고 (A Report on Test Results of Pressure Operated Switch)

  • 권오승
    • 방재기술
    • /
    • 통권12호
    • /
    • pp.5-9
    • /
    • 1992
  • This reoprt is explained about test results of pressure operated switch for automatic fire extinguishing systems. It may include pressure operated Switch for automatic water supply control valves for use in automatic fire suppression system for fire protection service. The testing program was progressed devided by Two testing items, extermal oppearane test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

다출력 플라이백 컨버터를 위한 자동 동기 스위치 포스트 레귤레이터 (An Automatic Synchronous Switch Post Regulator for Multi-Output Flyback Converter)

  • 김호진;이해교;양승욱;목형수;최규하;이성주
    • 전력전자학회논문지
    • /
    • 제11권4호
    • /
    • pp.321-327
    • /
    • 2006
  • 본 논문은 다출력 전원장치에 적용되는 플라이백 컨버터를 위한 자동 동기 스위치 포스트 레굴레이터를 제안한다. 제안된 회로는 기존의 스위치 포스트 레굴레이터의 단점인 구동회로 구현 및 주 출력과 보조 출력의 동기의 어려움으로 인한 복잡한 회로구성이 새로운 자동동기 스위치로 간단하게 구성된다. 제안된 회로를 적용함으로서 각 출력의 전압가변과 정밀한 레굴레이션이 요구되는 다중출력 전원장치를 간단한 구성과 저렴한 가격으로 제작할 수 있으며, 이론적 해석 및 시뮬레이션 그리고 실험을 통하여 제안 회로의 타당성을 입증하였다.

태양광 스위치 제안 및 효용성 평가 (Suggestion of Photovoltaic Switch and Evaluation of Its Usability)

  • 장준호;이준호;정주환;장민석;이연식
    • 한국컴퓨터정보학회논문지
    • /
    • 제18권9호
    • /
    • pp.33-41
    • /
    • 2013
  • 본 논문에서는 CdS(황화 카드뮴) 광센서란 소자를 태양광 모듈로 대체하여, 신재생에너지를 통한 충전도 하며 이 전력으로 동작하는 태양광 스위치를 제안하고 이의 효용성을 실험/검증하고자 한다. 우선 기존의 CdS 광센서와 이를 포함한 자동 점멸 스위치의 동작 원리를 조사해 본 후, 태양광 모듈의 특성을 조사함으로써 기존의 광센서를 태양광 모듈로 대체가능할 지를 분석해 본다. 그 가능성을 확인해 본 후, 태양광 스위치 회로를 설계 및 구현한 후, 이의 특성을 실험해 봄으로써 기존 스위치를 대체 가능함을 보이고 그 특성들을 비교/평가해 본다. 연구 결과 제안하는 태양광 스위치가 기존의 자동 점멸 스위치를 대체 가능함을 확인하였을 뿐만 아니라, 보다 많은 장점들을 가지고 있음을 확인하였다.

정전비용과 신뢰도 분석을 통한 분할 개폐기의 적정 자동화율 도출 알고리즘에 관한 연구 (Study on the algorithm for the Reasonable Switch Automation Rate with Customer Interruption Cost and Reliability Evaluation)

  • 채희석;신희상;조성민;문종필;김재철
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.467-473
    • /
    • 2013
  • The addition of disconnect switches to a distribution feeder or the replacement of the manual switches with the automatic switches do, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder and reducing the outage section. However, the improvement of reliability in power distribution system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we suggest the algorithm for determining the reasonable switch automation rate in the power distribution system. We evaluate the customer interruption cost and reliability for several cases - these cases relate with the switch automation rate - in the domestic metropolitan power distribution system, estimate the effectiveness of changing the manual switch to automatic switch quantitatively. These results can help the determining on the disconnect switch's automation rate.

디지털 필터 설계를 이용한 자동 진공 콘덴서 스위치의 기술 동향 (A Technical Trend on Automatic Vacuum Capacitor Switch with Modified Digital Filter Design)

  • 오기수;장영호;윤주호;황종선;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1978-1979
    • /
    • 2007
  • In this paper, the authors introduce a high-speed microprocessor based on automatic vacuum capacitor switch with a modified digital filter design using distributed arithmetic. The automation trends particularly the automatic vacuum capacitor switch has helped ameliorate the power factor essentials and automatically triggered to close when the line current exceeds rated value. Microprocessor relays use digital filters to extract only the fundamental and attenuate harmonics. To provide optimum speed characteristics a distributed arithmetic based filter design in the microprocessor controller which not only enhances filtering speed but additionally enables lower power consumption at the cost of area has been introduced. The result is a unified description that describes a digital filter structure down to bit level.

  • PDF

마이크로컴퓨터에 의한 시설재배의 자동화에 관한 기초연구(I) (A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(I))

  • 김철수;김진현
    • Journal of Biosystems Engineering
    • /
    • 제19권2호
    • /
    • pp.99-111
    • /
    • 1994
  • Automatic control system using microcomputer that have been studied in greenhouse, however, it was very difficult operation with success due to handicap for a various conditions and cultivated plants. This study was performed in order to develop of the basic program and hardware system for automatic control in greenhouse, such as automatic supplying of water, liquefied fertilizer solution and chemical solution. The results were summarized as follows. 1. The program for soil moisture control used by the switch type tensiometer was well operated. 2. The proximity switch was applied as well to water level control but it was very expensive, so low-priced sensor has to be developed. 3. The water meter was not excellent for mixing control of liquefied fertilizer, chemical and water, so water meter for only agricalture has to be developed. 4. Interface system for this study was suited to the developed controller. 5. Automatic control system to supply for water, liquefied fertilizer and chemical solution that was well operated as a fundamental study for product of controller.

  • PDF

적정 배전계통 구성을 위한 선로분할 효과 분석 (Analysis of Distribution Line Sectionalizing Effects for The Probable Distribution System Configuration)

  • 김재환;하복남;남기영;이주광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.86-89
    • /
    • 1993
  • This paper contains the various effect of distribution feeder sectionalizing by distribution automation. The effect by automatic sectionalizing switch and the effect by manual switch are analyzed and shown according to the radial feeder and the loop feeder respectively. Based on the reliability analysis, the reference for the feeder division and sectionalization is recommended. Also, the necessary number of manual switch where the automatic switch is installed is recommended through the reliability analysis.

  • PDF

Automatic Switching of Clustering Methods based on Fuzzy Inference in Bibliographic Big Data Retrieval System

  • Zolkepli, Maslina;Dong, Fangyan;Hirota, Kaoru
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제14권4호
    • /
    • pp.256-267
    • /
    • 2014
  • An automatic switch among ensembles of clustering algorithms is proposed as a part of the bibliographic big data retrieval system by utilizing a fuzzy inference engine as a decision support tool to select the fastest performing clustering algorithm between fuzzy C-means (FCM) clustering, Newman-Girvan clustering, and the combination of both. It aims to realize the best clustering performance with the reduction of computational complexity from O($n^3$) to O(n). The automatic switch is developed by using fuzzy logic controller written in Java and accepts 3 inputs from each clustering result, i.e., number of clusters, number of vertices, and time taken to complete the clustering process. The experimental results on PC (Intel Core i5-3210M at 2.50 GHz) demonstrates that the combination of both clustering algorithms is selected as the best performing algorithm in 20 out of 27 cases with the highest percentage of 83.99%, completed in 161 seconds. The self-adapted FCM is selected as the best performing algorithm in 4 cases and the Newman-Girvan is selected in 3 cases.The automatic switch is to be incorporated into the bibliographic big data retrieval system that focuses on visualization of fuzzy relationship using hybrid approach combining FCM and Newman-Girvan algorithm, and is planning to be released to the public through the Internet.