• Title/Summary/Keyword: Automatic phase-shift

Search Result 30, Processing Time 0.032 seconds

An Upshift Improvement in the Quality of Forklift's Automatic Transmission by Learning Control (학습제어를 이용한 지게차 자동변속기 상향 변속품질 개선)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.19 no.2
    • /
    • pp.17-26
    • /
    • 2022
  • Recently, automatic transmissions caused a good improvement in the shift quality of a forklift. An advanced shift control algorithm, which was based on TCU firmware, was applied with embedded control technology and microcontrollers. In the clutch-to-clutch shifting, one friction element is released and the other friction element is activated. During this process, if the release and application timings are not synchronized, an overrun or tie-up occurs and ultimately leads to a shift shock. The TCU, which measures only the speed of the forklift, inevitably applies the open-loop shift control. In this situation, the speed ratio does not change during the clutch fill. The torque phase occurs until the clutch is disengaged. In this study, an offline shift logic of the learning control was proposed. It induced a synchronous shift when the learning control progressed. During this process, the reference current trajectory of the release clutch was corrected and applied to the next upshift. We considered the results of the overrun/tie-up characteristics of the upshift performed immediately before. The vehicle test proved that the deviation in shift quality, which was caused by the difference in the mechanical characteristics of the clutch, could be improved by the learning control.

Development of Clutch Auto Calibration Algorithm for Automatic Transmission Shift Quality Improvement (자동변속기 변속품질 향상을 위한 클러치 자동보정 알고리즘 개발)

  • Jung, Gyuhong
    • Journal of Drive and Control
    • /
    • v.17 no.3
    • /
    • pp.47-56
    • /
    • 2020
  • As a shift control of automatic transmission was managed with the electronic control unit (ECU), shift quality which is a measure of shift shock during gear change has markedly improved. However, the initial clutch pressure control of the clutch filling phase should continue to rely on the predetermined control input since the input and output speeds are unchanged until the shifting process attains the inertia phase. It is critical to minimize the clutch response time and control the clutch pressure accurately at the end of clutch fill to achieve quick shift response and smoothness. Advanced transmission companies have adopted an auto calibration method which establishes the databases for the clutch piston fill-up attributes and the frictional characteristics of the disks. In this study, a distinctive auto calibration algorithm for forklift transmission under development is proposed and verified with the real-vehicle test. The experimental calibration results showed consistent turbine dynamics at the initial stage of shifts with the properly calibrated clutch-fill control parameters. By using this technique, it is necessary to finalize the shift control for the various operation conditions.

A Joint Scheme of AGC and Gain/Phase Mismatch Compensation for QPSK DCR

  • Song, Yun-Jeong;Lee, Ho-Jin;Ra, Sung-Woong;Kim, Young-Wan
    • ETRI Journal
    • /
    • v.26 no.5
    • /
    • pp.501-504
    • /
    • 2004
  • This paper presents a simple gain/phase blind compensation algorithm with an automatic gain control (AGC) function for the adoption of the AGC function and compensation for gain/phase imbalances in quadrature phase shift keying (QPSK) direct conversion receivers (DCRs). The AGC function is interactively operated with the compensation algorithm for gain/phase imbalances. By detecting the gain sum and difference values between the I-channel and Q-channel, the combined AGC and gain imbalance compensation algorithm provides a simpler DCR architecture.

  • PDF

Self-Learning Supervisory Control of a Power Transmission System in a Construction Vehicle during Inertia Phase (건설장비용 동력전달계의 관성영역에서의 자기학습 제어기법)

  • Choi, Gil-Woo;Hahn, Jin-Oh;Hur, Jae-Woong;Cho, Young-Man;Lee, Kyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.723-729
    • /
    • 2001
  • Electro-hydraulic shift control of a vehicle automatic transmission has been predominantly carried out via an open-loop control based on numerous time-consuming calibrations. Despite remarkable success in practice, the variations of system characteristics inevitably deteriorate the performance of the tuned open-loop controller. As a result, the controller parameters need to be continuously updated in order to maintain satisfactory shift quality. This paper presents a self-learning algorithm for automatic transmission shift control in a construction vehicle during inertia phase. First, an observer reconstructs the turbine acceleration signal (impossible to measure in a construction vehicle) from the readily accessible turbine speed measurement. Then, a control algorithm based on a quadratic function of the turbine acceleration is shown to guarantee the asymptotic convergence (within a specified target bound) of the error between the actual and the desired turbine accelerations. A Lyapunov argument plays a crucial role in deriving adaptive laws for control parameters. The simulation and hardware-in-the-loop simulation (HILS) studies show that the proposed algorithm actually delivers the promise of satisfactory performance despite the system characteristics variations and uncertainties.

  • PDF

Nonlinear Control of an Automatic Transmission Using Sliding Mode (슬라이딩모드를 이용한 자동변속기의 비선형제어)

  • 조승호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.3
    • /
    • pp.605-614
    • /
    • 1995
  • In the automatic transmission using planetary gear there exists nonlinearities due to the finite difference between gear ratios, which yield torque hole during shift and influence on the ride quality and life of clutch. Based on the reaction carrier and converter turbine speed sliding functions are defined. Nonlinear closed-loop control laws are derived using them. Computer simulation shows that the closed loop design is better than the open loop design and semi-closed loop design.

Feedback Shift Controller Design of Automatic Transmission for Tractors (트랙터 자동변속기 되먹임 변속 제어기 설계)

  • Jung, Gyu Hong;Jung, Chang Do;Park, Se Ha
    • Journal of Drive and Control
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • Nowadays automatic transmission equipped vehicles prevail in construction and agricultural equipment due to their convenience in driving and operation. Though domestic vehicle manufacturers install imported electronic controlled transmissions at present, overseas products will be replaced by domestic ones in the near future owing to development efforts over the past 10 years. For passenger cars, there are many kinds of shift control algorithms that enhance the shift quality such as feedback and learning control. However, since shift control technologies for heavy duty vehicles are not highly developed, it is possible to improve the shift quality with an organized control method. A feedback control algorithm for neutral-into-gear shift, which is enabled during the inertia phase for the master clutch slip speed to track the slip speed reference, is proposed based on the power transmission structure of TH100. The performance of the feedback shift control is verified by a vehicle test which is implemented with firmware embedded TCU. As the master clutch engages along the predetermined speed trajectory, it can be concluded that the shift quality can be managed by a shift time control parameter. By extending the proposed feedback algorithm for neutral-into-gear shift to gear change and shuttle shift, it is expected that the quality of the shift can be improved.

Islanding Detection Method for Grid-connected PV System using Automatic Phase-shift (자동 위상 이동을 이용한 계통 연계형 태양광 발전 시스템의 고립운전 검출기법)

  • Yun, Jung-Hyeok;Choi, Jong-Woo;So, Jung-Hun;Yu, Gwon-Jong;Kim, Heung-Geun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.107-114
    • /
    • 2007
  • Islanding of PV systems occurs when the utility grid is removed but the PV systems continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. This can present safety hazards and the possibility of damage to other electric equipments. In the passive method, the voltage and frequency of PCC are measured and it determines islanding phenomena if their values excess the allowed limits. If the real and reactive power of RLC load and those of the PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding operation in the region where the passive method can not detect it. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new islanding detection method using automatic phase-shift is proposed and its validity is verified through the simulation and experimental results.

Design of Carrier Recovery Circuit for High-Order QAM - Part II : Performance Analysis and Design of the Gear-shift PLL with ATC(Automatic Transfer-mode Controller) and Average-mode-change Circuit (High-Order QAM에 적합한 반송파 동기회로 설계 - II부. 자동모드전환시점 검출기 및 평균모드전환회로를 적용한 Gear-Shift PLL 설계 및 성능평가)

  • Kim, Ki-Yun;Kim, Sin-Jae;Choi, Hyung-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.38 no.4
    • /
    • pp.18-26
    • /
    • 2001
  • In this paper, we propose an ATC(Automatic Transfer mode Controller) algorithm and an average-mode-change method for use in Gear shift PLL which can automatically change loop gain. The proposed ATC algorithm accurately detects proper timing or the mode change and has a very simpler structure - than the conventional lock detector algorithm often used in QPSK. And the proposed average mode change method can obtain low errors of estimated frequency offset by averaging the loop filter output of frequency component in shift register. These algorithms are also useful in designing ASIC, since these algorithms occupy small circuit area and are adaptable for high speed digital processing. We also present phase tracking performance of proposed Gear-shift PLL, which is composed of polarity decision PD, ATC and average mode change circuit, and analyze the results by examining constellation at each mode.

  • PDF

The Laser Range Finder for the Mobile Robot Navigation using a Lock-in Amplifier

  • Yoon, Hee-Sun;Shin, Myung-Kwan;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1423-1426
    • /
    • 2005
  • Map building is the most important thing for the mobile robots navigation. It requires specific vision system such as CCD camera, range finding system, and many other things. Laser range finder has highly collimated beams can be obtained easily, thus achieving lateral resolution. Laser Diode is used for a continuous laser source. The Automatic Current Control Circuit and the Bias-T is used for mix AC signal with DC bias. This signal is used for driving Laser Diode. The main idea of the calculating distance is detecting phase shift between reference signal and detected signal by photo detector. For the signal processing, the Lock-in amplifier system is addressed in this paper. We used a diffused reflected beam to detect phase shift in this system. But this beam is minuteness signal so it can be easily buried in nose. Lock-in amplifier is used to measure the amplitude and phase of signals which are buried in noise.

  • PDF

The Design of a RF Automatic Gain Control Amplifier with Low Phase Shift Attenuator (저위상 변화 감쇄기를 이용한 RF 자동 이득 조정 증폭기 설계)

  • Park, Ung-Hee;Chang, Ik-Su;Huh, Jun-Won;Gang, In-Ho
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.15-21
    • /
    • 1999
  • A new design of RF automatic gain control amplifier with low phase shift attenuator is proposed. By using the RF AGC amplifier, the output level of amplifier becomes to be constant. The error is 0.1dB. In addition, for arbitrary RF input power, it is possible to design the gain of amplifier to be fixed. If the constant gain is maintained, it is more reliable to make wanted IMD(Intermodulation Distortion) characteeristic amplifier.

  • PDF