• Title/Summary/Keyword: Automatic monitoring

Search Result 895, Processing Time 0.024 seconds

Implementation of Indoor Environment Monitoring and Automatic Control System based on Internet of Things (사물인터넷 기반 실내 환경 모니터링 및 자동제어 시스템 구현)

  • Lee, Sang Hoon;Kim, Jin-Yeop;Kim, Su-Yeon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.6
    • /
    • pp.71-80
    • /
    • 2016
  • Along with the increase in the standard of living, the interest and awareness level of the public about environmental issues have also gradually increased. Recently, time spent on indoor activities have increased and the need for awareness and demand on methods in improving the quality of an indoor environment has been recognized. The purpose of this study is to sense the environment information through real-time monitoring of the room environment by using the IoT based technology and to maintain and improve the indoor environment to an appropriate level through the developed interlocking controller device. This provides an automatic control system in improving the indoor environment at home and other small areas like general offices in place of the traditional passive interior environmental improvement actions or large-scale facility control system. A status analysis with the relative reference values of the air quality and CO2, temperature and humidity and illumination and noise was applied through transmitting a control signal to automatic control module in accordance with the nine indoor environment standards set to improve the indoor environment.

High Speed PLC-based Automatic Control System for a Smart LED Streetlight (스마트 LED 가로등을 위한 고속 전력선 통신 기반 자동제어 시스템)

  • Kim, Young-Suk;Lin, Chi-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.95-102
    • /
    • 2014
  • In this paper, we propose the high speed PLC-based automatic control system for a smart LED streetlight. The proposed the automatic control system were constructed of a power line modem part and monitoring part, streetlight controller part for the high speed communication frequency band and streetlight ballasts characterization and real-time remote control using a high-speed PLC network, and it was designed to meet to lighting grades conditions of KS road lighting standards. The proposed automatic control system were easy monitoring of the power consumption using PC through to the comparison result of the existing streetlight system. As a result, it was confirmed to the possibility of efficient operation for the real-time monitoring and maintenance by induction of reasonable power consumption through to the LED streetlight state checking and remote-control. In addition, we proved to improvement of expected effects for the power cost savings, the energy efficiency, and streetlight differentiation and advanced.

Automated Method for the Efficient Management of DNSSEC Singing Keys in Korea (국내 DNSSEC 서명키의 효율적인 관리를 위한 자동화 방안)

  • Choi, Myung Hee;Kim, Seung Joo
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.8
    • /
    • pp.259-270
    • /
    • 2015
  • In this paper, we study and implement ways for users to easily apply and manage the DNSSEC in a domestic environment. DNSSEC is the DNS cache information proposed to address the vulnerability of modulation. However, DNSSEC is difficult to apply and manage due to insufficient domestic applications. In signing keys for efficient and reliable management of DNSSEC, we propose proactive monitoring SW and signing keys. This is an automatic management s/w signing key for DNSSEC efficient and reliable management and to provide a monitoring of the signing key. In addition to the proposed details of how DNSSEC signing key update and monitoring progress smoothly, we expect that the present study will help domestic users to apply and manage DNSSEC easily.

Survey on the Korean MCS Systems and Development Issues (국내 MCS 시스템 현황 및 발전 방향)

  • Kim, Geon-Ung;Park, Gyei-Kark;Choi, Jo-Cheon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2019-2029
    • /
    • 2009
  • There are several MCS(Monitoring, Control and Surveillance) systems for maritime safety and security in Korea; VMS (Vessel Monitoring System) that based on the AIS(Automatic Identification System), and the LRIT(Long-Range Identification and Tracking), the Vessel Free Pass System that based on the RFID(Radio Frequency IDentification), the Fisheries Information Network that provided by the National Federation of Fisheries Cooperatives. This paper surveys the fundamental technologies of MCS systems, and compares the role and function of them. It also surveys the development direction of each systems and research topics for cooperation of them.

Auto Dispatch Device of Parturition Beginning Signal by Temperature and a Load Sensor at Ubiquitous Circumstance in Pig Industry (양돈산업에 있어서 유비쿼터스 환경에서 온도 및 하중 센서에 의한 자동 분만 알림 시스템 개발)

  • Lee, Jang-Hee;Baek, Soon-Hwa;Yon, Seung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.33 no.3
    • /
    • pp.139-146
    • /
    • 2009
  • This study tried to develop the system (device) that automatically notify a manager of condition just before and after farrowing to extend ubiquitous-based technology and to increase efficiency of delivery care and productivity by reducing human labor and time on standby when farrowing management is done in the difficult and hard working environment of farrowing such as night or holidays in field sand especially in pig industry. In this test, selected 10 gilts were executed timed artificial insemination and were set up each temperature sensor and load sensor to them 3 days before the estimated farrowing day and were observed the farrowing situation. This study was embodied the NESPOT-based (KT Corporation) monitoring system, the system to transmit data in real time by utilization of wireless LAN and the sensor module to apply the ubiquitous environment to them. And this study was observed the situation to automatically notify situations of 10 gilts that first bore just before and after farrowing. The result obtained the farrowing situations of them in real time by setup of the NESPOT-based monitoring system to check farrowing situation directly is as follow. The average time of the automatic notice about situation just before farrowing by the temperature sensor was 27.5 minutes before the beginning of farrowing (the expulsion time of a piglet). 6 of 8 pregnant gilts that first bore automatically were notified situations just before farrowing and the temperature sensors inserted into 2 ones before farrowing were omitted. (The automatic notice rate 75%) The average time of the automatic notice of situation just after farrowing by the load sensor was taken 46.5 minutes after the beginning of farrowing (the expulsion time of a first piglet). The average gestation period of 8 ones that first bore and were tested by the automatic notice of farrowing situation was 115.6 days. This result found that the automatic farrowing notice system by the temperature sensor is more efficient than the load sensor as the automatic farrowing alarm device and sanitary treatment and improvement of the omission rate were required.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Automatic Analysis of Gamma Ray Spectra for Surveillance of the Nuclear Fuel Integrity (핵연료 건전성 점검을 위한 감마선 스펙트럼의 자동 분석)

  • Cho, Joo-Hyun;Yu, Sung-Sik;Kim, Seong-Rae;Hah, Yung-Joon
    • Nuclear Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.555-561
    • /
    • 1994
  • The program of performing a fast and automatic analysis of gamma ray spectra obtained by a Multi-Channel Analyzer (MCA) is developed for the surveillance of the nuclear fuel integrity. The integrity of the nuclear fuel is confirmed by the measurement of the radiation level of the reactor coolant through the real time monitoring and the periodic sampling analysis. In Yonggwang nuclear power plane 3 and 4, the Process Radiation Monitoring System (PRMS), which is a real time monitoring system, provides a measure of the fuel integrity. Currently, its spectrometer channel can identify only one radionuclide at a time since the signal processing unit of the spectrometer channel is a Single Channel Analyzer (SCA). To improve the PRMS, it is necessary to substitute the MCA for the SCA The program is operated in a real time mode and an on-demand mode, and automatically performed for all procedures. The test results by using the National Bureau of Standards (NBS) mixed standard source are in good agreement with those from Canberra System 100 which is a commercial MCA Consequently, the developed program seems to be employed for automatic monitoring of gamma rays in nuclear power plants.

  • PDF