• Title/Summary/Keyword: Automatic measurement

Search Result 1,014, Processing Time 0.038 seconds

Current Status of Automatic Fish Measurement (어류의 외부형질 측정 자동화 개발 현황)

  • Yi, Myunggi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.5
    • /
    • pp.638-644
    • /
    • 2022
  • The measurement of morphological features is essential in aquaculture, fish industry and the management of fishery resources. The measurement of fish requires a large investment of manpower and time. To save time and labor for fish measurement, automated and reliable measurement methods have been developed. Automation was achieved by applying computer vision and machine learning techniques. Recently, machine learning methods based on deep learning have been used for most automatic fish measurement studies. Here, we review the current status of automatic fish measurement with traditional computer vision methods and deep learning-based methods.

A Study on Analysis of Dimensional Error of Projector for Formulations of Measurement Automation (측정 자동화 구축을 위한 투영기의 치수오차 분석에 관한 연구)

  • Choi, Jisun;Kim, Moon Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.114-118
    • /
    • 2021
  • In this research, the dimensional error of the measured specimen according to the measurement method was analyzed for the length, angle, radius of curvature and diameter using a projector which is used in industry. One-way analysis was performed on each data tested 30 times using a statistical technique. Through the experiment, it was found that an error occurred in each data when measuring the length and radius of curvature according to the measurement method, and the null hypothesis that no error occurred when measuring the angle and length was established. Based on this experimental data, the automatic measurement when measuring the projector causes less measurement error, so automatic measurement is recommended when measuring a small product. Also, an optimal measuring method is suggested for securing reliability on formulations of measurement automation.

Development of an Automatic Evaluation System for the Precision Analysis of Potential Transformer Burden Characteristics (전압변성기용 부담특성 정밀분석용 자동평가시스템의 개발)

  • Kwon, Sung-Won;Kim, Mun-Seog;Jung, Jae Kap;Lee, Sung-Ha;Kim, Yung Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.457-464
    • /
    • 2005
  • Both ratio error and phase angle error in potential transformer(PT) are critically affected by used burden, connected in parallel to the secondary terminal of the PT. Thus precise measurement of burden value is very important for the evaluation of PT An automatic measurement system has been developed for the measurement of burden value and power factor of a burden. The ac voltage, current and power of the burden are measured precisely, and the burden value and power factor were calculated from these measured values. The resistance and inductance values of the tested burden are also calculated. The overall measurement uncertainties are calculated and reported with the burden value and power factor. The best measurement uncertainty for the burden measurement with the developed automatic measurement system was estimated to be 0.5 $\%$.

Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator (IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구)

  • Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

Automatic control of experimental apparatus for sound's directivity measurement direction acoustic wave (소리의 방향성 측정을 위한 실험기기의 자동제어)

  • Jarang, Sun-Suck;Ko, Jae-Ha;Lee, Je-Hyeong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.591-594
    • /
    • 2004
  • The directivity of the sound pressure increases the sensitivity of the incoming sound from specific directions. The directivity measurement of the sound pressure is usually done in an anechoic room using a steping motor. In this paper a replaceable anechoic chamber was designed for the acoustic directivity pattern measurement. Electrical equipments were interfaced with a PC for experiment automatic control. Some comparative results are shown in the result.

  • PDF

Accuracy Comparison of Blood Pressure among the Direct Measurement Method and Two Automatic Indirect Measurement Methods in the Patients with Various Blood Pressure (다양한 혈압상태에서 직접혈압을 기준으로 HP 자동혈압기와 국산자동혈압기의 정확도 비교)

  • Song Hyo-Sook;Jun Tae-Gook;Choi Eun-Jung;Kim Mi-Jung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.8 no.3
    • /
    • pp.366-378
    • /
    • 2001
  • Objective: The purpose of this study was to identify differences in measurement methods for blood pressure (Direct measurement, HP automatic indirect measurement, and SE 7000 Korean made indirect measurement), and to evaluate the clinical trial of the Korean made automatic indirect blood pressure measurement. Material & Methods: From June, 1999 to February, 2000, fifty five consecutive patients were randomized into hypertension group (n=20), normotension group (n=20), and hypotension group (n= 15). Measuring blood pressure by indirect methods (HP NIBP M 1008B and SE 7000 NIBP Korean made) was done simultaneously in the same arm with arterial line for direct blood pressure measurement (HP M1006A). The procedures were repeated ten times at intervals of 2 minutes. Statistical analysis was Performed using SPSS (version 8.0 for windows) software package. Values were expressed as means and standard deviation and means were compared using t-test. Statistical significance was considered present with a p value less than 0.05. Results: In the hypertension group and noromotension group, the disparity between HP direct measurement and indirect SE 7000 NIBP did not show any differences compared to the disparity between HP direct measurement and indirect HP NIBP. In the hypotension group, the disparity in the diastolic pressure between HP direct measurement and indirect SE 7000 NIBP was significantly different compared to the disparity between HP direct measurement and indirect HP NIBP (p<0.001), however, disparities in systolic pressure did not showed any differences. Conclusion: Direct blood pressure measurement (HP M1006A) can be replaced with indirect blood pressure measurements (HP NIBP M 1008B & SE 7000 NIBP) in normotension and hypertension patients. Korean made indirect measurement was found to be more accurate compared to HP indirect measurement in hypotension Patients, but more study is needed.

  • PDF

A Study of Incline Measurement using High Accuracy Digital Datalogger System for Railway Structures (고정밀 24비트 디지털 데이터로거를 이용한 철도구조물의 경사계측에 관한 연구)

  • Lee, Seong-Won;Lee, Keun-Ho;Chung, Jae-Min
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.249-254
    • /
    • 2008
  • The objective of this study is the developement of real time automatic incline measurement using high accuracy digital datalogger for safety and maintence of railway construction sites. For the replacement of current 16 bit analog/digital converter, Digital datalogger system using 24 bit analog/digital converter is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the automatic high accuracy digital datalogge system. The results of this study will be using real time automatic incline measurement of railway structures.

  • PDF

A Study on the Evaluation of the Automatic Measurement Method of Plastic Strain Ratio by Two Extensometers (신장계에 의한 소성변형비 자동측정법의 평가에 관한 연구)

  • 김인수
    • Transactions of Materials Processing
    • /
    • v.12 no.5
    • /
    • pp.504-512
    • /
    • 2003
  • The plastic strain ratios(R-values) of low carbon steel sheets were determined by the automatic strain measurement method using two extensometers, the indirect photo method for the same tensile specimen during tensile test and the indirect method for the specimen after tensile test. The experimental results showed that the measured plastic strain ratios from the automatic strain measurement method using two extensometers coincided with those from the indirect photo method and the indirect method for all tensile specimens. In addition, the strain dependence of plastic strain ratios could be continuously recorded and the anisotropy of the strength coefficient, K, and strain hardening exponent, n, could be automatically calculated in three directions by computer through the use of two extensometers. The experimental results showed that the strain dependence of R-value was related to the anisotropy of strain hardening exponent in low carbon steel sheets.

A Study of Dynamic Measurement using High Accuracy Digital Datalogger System for Railway Structures (철도구조물 진동계측에의 고정밀 디지털 데이터로거 적용성 연구)

  • Lee, Seong-Won;Lee, Keun-Ho;Chung, Jae-Min
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1006-1011
    • /
    • 2008
  • The objective of this study is the developement of real time automatic dynamic measurement using high accuracy digital datalogger for safety and maintence of railway construction sites. For the replacement of current 16 bit analog/digital converter, Digital datalogger system using 24 bit analog/digital converter is studied for the first time with in a country. Therefore data communication method and analyzing program of automatic measurement data is developed for the automatic high accuracy digital datalogger system. The results of this study will be using real time automatic dynamic measurement of railway structures.

  • PDF

Development of automatic measurement method of concentricity and roundness using image processing technique

  • Moon, Hyung-Wook;Huh, Kyung-Moo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.130.2-130
    • /
    • 2001
  • In this paper, we suggest an algorithm for the automatic measurement of concentricity and roundness using image processing technique. From the experimental results, we could find that the required measurement accuracy specification is sufficiently satisfied using our proposed method.