• Title/Summary/Keyword: Automatic low pressure

Search Result 53, Processing Time 0.045 seconds

An automatic calibration technique for piezoelectric pressure transducers (압전형 압력센서의 교정기법 자동화)

  • Hong, Sung-Soo;Choi, Ju-Ho;Yoo, Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1368-1371
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectric low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

An Automatic Calibration Technique for Piezoelectric Pressure Transducers (압전형 압력센서의 교정기법 자동화)

  • 홍성수;최주호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.1012-1016
    • /
    • 1996
  • This paper presents an automatic calibration technique for piezoelectic low pressure transducer, which is useful to measure a pressure within 500 psi. This system with automatic calibration function and error correction algorithm generates standard dynamic pressure for the calibration of sensor. With the compensation for the offset voltage and the pressure error, the accuracy and the usefulness of the proposed scheme is validated.

  • PDF

An automatic calibration technique for piezoelectric pressure sensors (압전형 압력센서의 교정기법 자동화)

  • Choi, Ju-Ho;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.4
    • /
    • pp.357-362
    • /
    • 1997
  • This paper suggests an automatic calibration technique for piezoelectric low pressure transducer measuring a pressure blow 500psi. The present calibration system embedded with error correction algorithm generates it's best you don't cut parts of wards like so dynamic pressure and compensates offset voltage and pressure error. It is shown via experimental results that the instrumentation accuracy has been improved and mean time between calibrations has been shortened.

  • PDF

The developing direction of korean gas pressure welding machine (철근 가스압접공법 활성화를 위한 한국형 철근자동가스압접기 기술개발방향)

  • Seo, Deok-Seok;Song, Ki-Jun;Hwang, Kee-Tae;You, Beong-Taek
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.3 s.17
    • /
    • pp.131-138
    • /
    • 2005
  • The study is focused on the settling the developing direction of korean gas pressure welding machine which can be applied in korean construction sites with moderate and high performance. Gas pressure welding is more economical and has good performances than other steel bar jointing methods, as arc welding and mechanical joint etc. Therefore in Japan, the gas pressure welding, which has less loss of steel bars and low performance of joints, when connecting the D29 and thicker steel bars, Is one of the typical connection of steel reinforcement. But in Korea, the gas pressure welding method is not widely used caused by the shortage of skilled workers, and this situation in Korea can not be solved in short period. The training of the skilled workers takes long period(around $6\~10$ years), and there is no certification system for gas pressure welding. So to activate the gas pressure welding in Korea, the development of the automatic gas pressure welding machine is necessary, which gives regular performance of the steel bar joints and can be operated by not sufficient skilled workers. The automatic gas pressure welding machine was developed in Japan, but this machine has many problems when applied in korean construction sites. Therefore, it is necessary to develop a korean automatic gas pressure welding machine to overcome this problems. To develop korean automatic gas pressure welding machine, the problems, which shows when applied in korean construction sites, need to be investigated. According to the investigation, counterproposals are presented for the pragmatical development of the korean automatic gas pressure welding machine.

An Automatic Control System of the Blood Pressure of Patients Under Surgical Operation

  • Furutani, Eiko;Araki, Mituhiko;Kan, Shugen;Aung, Tun;Onodera, Hisashi;Imamura, Masayuki;Shirakami, Gotaro;Maetani, Shunzo
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.1
    • /
    • pp.39-54
    • /
    • 2004
  • We developed an automatic blood pressure control system to maintain the blood pressure of patients at a substantially low level during a surgical operation. The developed system discharges two functions, continuous feedback control of the mean arterial pressure (MAP) by a state-predictive servo controller and risk control based on the inference by fuzzy-like logics and rules using measured data. Twenty-eight clinical applications were made beginning in November 1995, and the effects of the automatic blood pressure control on the operation time and on bleeding were assessed affirmatively by means of Wilcoxon testing. This paper essentially reports the engineering details of the control system.

Time for Young Adults to Reach Resting Blood Pressure after Walking as measured by an Automatic and a Mercury Sphygmomanometer (20대 성인의 보행 후 휴식시간에 따른 진동식 자동혈압계와 수은혈압계의 안정혈압 도달 시점)

  • Choi, Min-Jung;Sohng, Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.21 no.4
    • /
    • pp.370-379
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the time for young adults to reach resting blood pressure after walking as measured by an automatic and a mercury sphygmomanometer. Methods: Participants were 33 nursing students in their 20s. Blood pressure after walking was measured every minute on both arms simultaneously for a total of 6 times after walking for 12 minutes on a treadmill at ratings of perceived exertion (RPE) of 11. Data were analyzed using paired t-test, Bland-Altman plots and repeated measures ANOVA. Results: Systolic blood pressure after walking was the same as measurements corresponding to resting blood pressure after 3 minutes of resting if measured with the automatic sphygmomanometer and 4 minutes of resting if measured with the mercury sphygmomanometer. Conclusions: In order to measure the resting blood pressure for healthy young adults who performed low-density walking for 12 minutes on flat land, the measurement needs to be made after a resting time of at least 3 minutes in the case of an automatic sphygmomanometer and 4 minutes in the case of a mercury sphygmomanometer.

A Study on Pump Down Operation Performance of Refrigerator (냉동기 펌프다운 운전성능에 관한 연구)

  • Kim, Chul-Soo;Chung, Han-Shik;Jeong, Hyo-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.964-970
    • /
    • 2006
  • Vapor compression refrigerators have much critical variables such as the controls of temperature and pressure switches, control durations and operating hours of electronic valves. This study compares and analyzes the data which is obtained from system controlling of the evaporation temperatures which are generally used in automatic pump down operating systems. Through this study, the automatic evaporation control operation system will be more ideal for the system to keep the proper temperature distribution depending on the purpose of evaporation side. The automatic pump down control operation is more appropriate for the system to aim at the effective use of evaporation side without using the temperature difference. And this test will be proved that the changes at the low pressure side didn't have significant impacts on the high pressure side.

Development of Automatic Ultrasonic Testing Techniques of Low Pressure Turbine Blade of Nuclear Power Plants (원자력 발전소 저압 터빈 동익 자동 초음파 검사 기술 개발)

  • Yang, Seung-Han;Lee, Jeong-Bin;Kim, Young-Ho;Yoon, Byung-Sik;Kim, Yong-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.371-377
    • /
    • 2004
  • As the turbine running duration in nuclear power plants increases, cracks have been found in the pin finger type blade root area. The nondestructive examination for the blade root area has been carried out by manual ultrasonic examination during the overhaul period, but because of necessity to improve the reliability, we developed an automatic ultrasonic examination system and technique. To demonstrate the performance of the developed automatic ultrasonic examination system, low pressure turbine blades in the 2nd and 3rd stages of nuclear power plants were examined using the developed system. Its applicability nuclear power plant turbine roots of various types was also confirmed.

A Study on the Repair and Strengthening Effects of Epoxy Grout for the Damaged Concrete Structure (손상된 콘크리트 구조물에 에폭시수지를 이용한 보수·보강효과에 대한 연구)

  • Shin, Sung-Woo;Cho, Tai-Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.1
    • /
    • pp.125-132
    • /
    • 1997
  • This study was intended to investigate the effects of epoxy grout on compressive strength for damaged concrete structures. For this purpose, concrete molds were manufactured and tested for compressive strength at 28 days after water curing. Two kinds of Korea-made and one Japan-made epoxy grouts were injected into the broken concrete molds with the automatic low-pressure injecting method or the hand injecting method.

  • PDF

Automatic control problems of VVVF converter-based variable-frequency type air (VVVF기를 기초한 가변식기압급수설비의 자동제어 문제)

  • 박용규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.468-468
    • /
    • 1991
  • The variable-frequency type water supply equipment, which adopts the variable-voltage and variable-frequency converter(VVVF converter) to govern automatically the rotating speed of a pump, can save 15-20% of power, as compared with a throttle-controlled pump device or an airpressurized water supply equipment, and is finding a wide application. However, it still has some disadvantages : greater pressure fluctuations during switching over the pump and prolonged low-effeciency running of the pump in the case of small consumption of water. Therefore, it is difficult to apply the equipment to the fire water supply system where the water should not be put into use unless a fire takes place, and the water pressure in pipelines should permanently remain constant. This paper introduces the automatic regulation principle of the variable-frequency type air-pressurized water supply equipment (hereafter referred to as simply BFQS equipment) for dual purposes of daily life and fire control, which combined both technologies of speed governing by a converter and air-pressurized water supplying, then discusses some problems related to automatic control, and finally gives the experimental results of an embodiment-BPQS-100-50 water supply equipment.

  • PDF