• Title/Summary/Keyword: Automatic heating

Search Result 104, Processing Time 0.02 seconds

Development of Y Strainer Type Automatic Flow Rate Regulating Valve (Y 스트레이너형 자동 정유량 조절 밸브의 개발)

  • Yoon, Joon-Yong;Kwon, Woo-Chul
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.1 s.40
    • /
    • pp.49-55
    • /
    • 2007
  • An 'Y' strainer type automatic flow rate regulating valve, which functions are to remove impurities from hot water inside the pipe and to maintain a constant flow rate regardless of variations of the differential pressure between valve inlet and outlet at the same time, is developed for distributing hot water equally to several pipes with district heating or central heating system. Numerical analysis of the three dimensional turbulent flow field in a valve shape is carried out to confirm the flow field whether the designed regulator shape is acceptable or not. The final developed valve improves installation time and cost and maintenance ability comparing with set-up 'Y' strainer and regulator separately. Tolerance for the nominal flow rate is also satisfied within ${\pm}5%$.

System Implementation for Fair Automatic Heating Operation Based on Spatial Distributing and Zonal Calorie Measuring (공간분활 및 영역열량측정에 의한 공평 자동난방운영시스템 구현)

  • Han, Sang Cheol;Ryu, Kwang Ryol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.8
    • /
    • pp.910-916
    • /
    • 2019
  • This paper describes the system implementation of the heating operation based on spatial distributing and zonal calorie measuring and analyzing of houses to calculate the fair amount of the heating meterage automatically. The heating space is distributed into 4 zones, which the flow rate and calories are checked by one meter respectively. The system is composed of a heating sources, adjuster of thermostat, valve controller, PC converter and total monitering. The returning temperature in the spatial zones is measured for the heating calorie to calculate the zonal calories according to the rooms temperature. The proposed system results in error by 1% or less in comparing with the dedicated experimental equipment, and reduces energy cost by 7% from conventional system. The fair checking system will be enhanced with building energy management system in the future.

The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW (LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법)

  • Kim, Dae-Nyeon;Kim, Deok-Hyun;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

Heat Response According to Fusible Metal Shapes in Automatic Fire Extinguishers (자동식소화기용 이융성금속 감지부 헝상에 따른 열감응 특성에 관한 연구)

  • 박용환
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.64-69
    • /
    • 2003
  • Low story apartments and housings with manual fire extinguishers are very susceptible to fro damages, when people are absent or there are old and weak peoples. To reduce such fire damages, automatic fire suppression at the early stage is very important, and thus automatic and cost-effec-tiye fire extinguisher was developed. This study revealed that the reaction temperature and response time are greatly influenced by the small thickness variation of the detective parts and heating rates. The influence of the thickness of the detective parts was shown significant when the heating rate was low, The reduction in the thickness could lower the response time to 40seconds.

A Study on the Strategy to Maintain Optimal Flow-rate and Pressure of the Piping System for Individual Heating (개별 난방방식에서의 배관 내 절정 유량 및 압력유지에 관한 연구)

  • Hong Seok-Jin;Ryu Seong-Ryong;Seok Ho-Tae;Yeo Myoung-Souk;Kim Kwang-Woo
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.11-18
    • /
    • 2006
  • For the more comfortable thermal environment in residential buildings, it was necessary for variable components like as automatic flow limiting valves and/or balancing valves in hydronic system. And, these components had an effect on flow-rate and pressure inside pipe. In this case, the incompatibility between the design for the heating system and the selection of equipment was the causes of several problems in heating pipe network. In this study, we peformed measurements and analyses of flow rate and pressure inside pipe for radiant floor heating in residential buildings through field surveys and experiments in order to find out the actual conditions and problems. On the basis of this, we suggested the approach for the optimal flow-rate and pressure maintaining inside pipe in individual heating system.

Research on the actual condition of 'Under Floor Radiant Heating for Apartment Housing' (주거용건물의 바닥복사 난방방식에 대한 실태조사 연구)

  • Woo, Byung-Kwan;Lee, Sung;Kim, Sam-uel
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.81-86
    • /
    • 2007
  • The research analyzes the arrangement of boiler and hot water header, the method of radiator pipe setting, hot water supply control, hourly heating situation of each room for underfloor radiant heating systems in Korea and suggests an alternative to improve to efficient heating method. One of the best options for install position of hot water distributor is under kitchen sink which is center point of all rooms, according to previous research of the energy saving strategies. When the radiator pipes are arranged to each individual room instead of bedrooms through livingroom and kitchen, it has energy saving effects. For rooms without occupancy according to a time period, hot water supply method should be intermittent heating rather than continuous heating. For this intermittent heating method, individual control of hot water supply is more practical, and it can lead to massive energy savings. The intermittent heating system has time-lag, so it is more effective in energy saving with mild and comfort condition if the spaces are preheated by automatic control equipment prior to required time.

Development of Automatic Tool Change System of the SMA-Based Tool Clamping Device (형상기억합금 기반 공구클램핑 장치를 위한 자동공구교환 시스템 개발)

  • Shin, Woo-Cheol;Ro, Seung-Kook;Kim, Byung-Sub;Park, Jong-Kweon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.5
    • /
    • pp.710-715
    • /
    • 2010
  • This study developed an automatic tool change system of the SMA-based tool clamping device for applications of micro-machine tools. This paper first describes clamping and unclamping procedures of the automatic tool change system and its basic configuration. Second, it presents fabrication techniques of components, such as a heating/cooling system and a tool loader. Finally, it describes automatic tool change test conducted with a prototype in which the fabrication techniques of components were employed. As the results of the test, times needed for clamping and unclamping operations were estimated to 18(s) and 8(s) respectively. The experimental results confirm that the proposed automatic tool change system can be sucessfully applied to micro-machine tools.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

Thermal Inactivation of Listeria monocytogenes in Liquid Cultures during Microwave Radiation (Microwave 조사에 의한 Listeria monocytogenes의 불활성에 관한 연구)

  • Lee, J.Y.;Kim, J.W.;Lee, K.W.;Bae, H.C.
    • Korean Journal of Agricultural Science
    • /
    • v.26 no.1
    • /
    • pp.50-57
    • /
    • 1999
  • The purpose of this study was to determine the thermal inactivation of L. monocytogenes KCTC3443 in liquid culture heated in the controlled microwave system and in the conventional heating method. Furthermore, we have carried out a comparative study on the thermal and nonthermal microwave effects on microorganisms, pasteurized using a controlled microwave energy specially designed apparatuses and a water bath. For the automatic temperature control during microwave heating, the real time data acquisition and computation system is designed with BASIC routine. The automatic temperature control system used in the experiments perform relatively stable control at the experiment temperature of 55, 65, $75^{\circ}C$ and $85^{\circ}C$ for 30 minutes. The effects of microwave heating on liquid cultures was compared with that of conventional heating. The results show that microwave radiation, while being slightly quicker than conventional heating, still reduces effectively the number of pathogenic bacteria during heating for a limit time in liquid cultures. While no particular differences between microwave heating and conventional heating was not observed in the thermal inactivation of L. monocytogenes at 55, 65, $75^{\circ}C$ and $85^{\circ}C$ for 30 min., respectively. Microwave heating is, therefore, substantially not effective in inactivating L. monocytogenes in liquid culture than conventional heating method.

  • PDF