• Title/Summary/Keyword: Automatic generation control

Search Result 266, Processing Time 0.026 seconds

Noise Control of Plate Structures with Optimal Design of Multiple Piezoelectric Actuators (복수 압전 가진기의 최적 설계를 통한 판구조물의 소음제어)

  • 김재환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.263-270
    • /
    • 1996
  • Noise control of a plate structure with multiple disk shaped piezoelectric actuators is studied. The plate is excited by an acoustic pressure field produced by a noise source located below the plate. Finite element modeling is used for the plate structure that supports a combination of three dimensional solid, flat shell and transition elements. The objective function, in the optimization procedure, is to minimize the sound energy radiated onto a hemispherical surface of given radius and the design parameters are the locations and sizes of the piezoelectric actuators as well as the amplitudes of the voltages applied to them. Automatic mesh generation is addressed as part of the modeling procedure. Numerical results for both resonance and off resonance frequencies show remarkable noise reduction and the optimal locations of the actuators are found to be close to the edges of the plate structure. The optimized result is robust such that when the acoustic pressure pattern is changed, reduction of radiated sound is still maintained. The robustness of an optimally designed structure is also tested by changing the frequency of the noise source using only the actuator voltages as design parameters.

  • PDF

A Design of an Improved Linguistic Model based on Information Granules (정보 입자에 근거한 개선된 언어적인 모델의 설계)

  • Han, Yun-Hee;Kwak, Keun-Chang
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.3
    • /
    • pp.76-82
    • /
    • 2010
  • In this paper, we develop Linguistic Model (LM) based on information granules as a systematic approach to generating fuzzy if-then rules from a given input-output data. The LM introduced by Pedrycz is performed by fuzzy information granulation obtained from Context-based Fuzzy Clustering(CFC). This clustering estimates clusters by preserving the homogeneity of the clustered patterns associated with the input and output data. Although the effectiveness of LM has been demonstrated in the previous works, it needs to improve in the sense of performance. Therefore, we focus on the automatic generation of linguistic contexts, addition of bias term, and the transformed form of consequent parameter to improve both approximation and generalization capability of the conventional LM. The experimental results revealed that the improved LM yielded a better performance in comparison with LM and the conventional works for automobile MPG(miles per gallon) predication and Boston housing data.

The automatic generation of MPTCP session keys using ECDH (MPTCP에서 ECDH를 이용한 세션 키 자동생성에 관한 연구)

  • Sun, Seol-hee;Kim, Eun-gi
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.10
    • /
    • pp.1912-1918
    • /
    • 2016
  • MPTCP(Multipath Transmission Control Protocol) is able to compose many TCP paths when two hosts connect and the data is able to be transported through these paths simultaneously. When a new path is added, the authentication between both hosts is necessary to check the validity of host. So, MPTCP exchanges a key when initiating an connection and makes a token by using this key for authentication. However the original MPTCP is vulnerable to MITM(Man In The Middle) attacks because the key is transported in clear text. Therefore, we applied a ECDH(Elliptic Curve Diffie-Hellman) key exchange algorithm to original MPTCP and replaced the original key to the ECDH public key. And, by generating the secret key after the public key exchanges, only two hosts is able to make the token using the secret key to add new subflow. Also, we designed and implemented a method supporting encryption and decryption of data using a shared secret key to apply confidentiality to original MPTCP.

An automation method for GUI test using a UIA library (UIA 라이브러리를 이용한 GUI 테스트 자동화 방법)

  • Choi, Chang-Min;Chung, In-Sang;Kim, Hyeon-Soo
    • The KIPS Transactions:PartD
    • /
    • v.18D no.5
    • /
    • pp.343-356
    • /
    • 2011
  • When preparing test cases and running the test the existing GUI test tools require many tester's interventions. To cope with such problem this paper suggests a new method to build test cases for GUI test. This method identifies the potential control flows within the GUI and constructs the GUI map. The UIA library in .NET Framework is used to extract information about the GUI controls and the GUI map is constructed by the extracted information. Test scenarios are generated from the extracted information about the GUI controls using the grouping mechanism. Based on the grouping mechanism, various test scenarios which are test cases in GUI tests can be made by replacing a GUI control by another one in the same group. The existing GUI test tools do not support the concept of test coverage. Since, however, our method survey which part of the GUI map is executed or not during running the test, the test coverage can be measured by using the GUI map.

Blockchain for Securing Smart Grids

  • Aldabbagh, Ghadah;Bamasag, Omaimah;Almasari, Lola;Alsaidalani, Rabab;Redwan, Afnan;Alsaggaf, Amaal
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.4
    • /
    • pp.255-263
    • /
    • 2021
  • Smart grid is a fully-automated, bi-directional, power transmission network based on the physical grid system, which combines sensor measurement, computer, information communication, and automatic control technology. Blockchain technology, with its security features, can be integrated with Smart Grids to provide secure and efficient power management and transmission. This paper dicusses the deployment of Blockchain technology in Smart Grid. It presents application areas and protocols in which blockchain can be applied to in securing smart grid. One application of each area is explored in detail, such as efficient peer-to-peer transaction, lower platform costs, faster processes, greater flexibility in power generation to transmission, distribution and power consumption in different energy storage systems, current barriers obstructing the implementation of blockchain applications with some level of maturity in financial services but concepts only in energy and other sectors. Wide range of energy applications suggesting a suitable blockchain architecture in smart grid operations, a sample block structure and the potential blockchain technicalities employed in it. Also, added with efficient data aggregation schemes based on the blockchain technology to overcome the challenges related to privacy and security in the smart grid. Later on, consensus algorithms and protocols are discussed. Monitoring of the usage and statistics of energy distribution systems that can also be used to remotely control energy flow to a particular area. Further, the discussion on the blockchain-based frameworks that helps in the diagnosis and maintenance of smart grid equipment. We have also discussed several commercial implementations of blockchain in the smart grid. Finally, various challenges have been discussed for integrating these technologies. Overall, it can be said at the present point in time that blockchain technology certainly shows a lot of potentials from a customer perspective too and should be further developed by market participants. The approaches seen thus far may have a disruptive effect in the future and might require additional regulatory intervention in an already tightly regulated energy market. If blockchains are to deliver benefits for consumers (whether as consumers or prosumers of energy), a strong focus on consumer issues will be needed.

Product Design and Manufacture on Safety Hook and X-jog for application in Hoist and Crane (호이스트 및 크레인에 적용 가능한 안전후크와 X-jog 제품 설계 및 제작)

  • Na, Hyun-Ho;Kim, Do-Jung;Choi, Ju-Seok;Oh, Woo-Jun;Park, Jae-Woong;Lee, Chon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.1
    • /
    • pp.91-96
    • /
    • 2015
  • In this study, we performed a study on prevention of the escape hoist heavy objects on the basis of the case of a disaster occurring during crane operations. A safety hook of the automatic fastening and coupling method by the conventional coupling method, the weight of the outside consisting of a combination of a safety ring structure was designed and manufactured. The main mechanism three-dimensional detail design and structural analysis confirmed the structure and stability of small strain than the allowable stress of the Safety Hook with X-jog through. Safety factor was confirmed to represent the average 1.5 to 1.2 higher than the safety factor to be considered in the general design structure. Therefore, Safety Hook and X-jog in the present study is to be operated upon structural stability is a structure attached to the hoist and crane are considered sufficient.

Development of advanced Power Factor Computation Algorithm in Harmonics distorted Distribution System (고조파 왜곡 환경에서 향상된 역률 계측 알고리즘 개발)

  • Lee, Hyun-woo;Park, Young-kyun;Lee, Jinhan;Joung, Sanghyun;Park, Chul-woo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.121-127
    • /
    • 2016
  • We propose a algorithm to calculate power factor of fundamental waveform in an environment where the voltage and current have been distorted by harmonics. In the proposed power factor computation algorithm, voltage and current are converted to rotating DQ reference frame, and power factor is calculated from active power and reactive power. We compare the proposed method with the conventional power factor measurement method as mathematically. In a condition that voltage and current are distorted by harmonics, the proposed method accurately measure the power factor of fundamental wave, and it is confirmed by simulation using MATLAB. If the proposed power factor measurement method is applied to an automatic power factor control system, a power factor compensation performance can be maximized in harmonic distortion environment. As a result, it is possible to reduce electricity prices, reduce line loss, increase load capacity, ensure the transmission margin capacity, and reduce the amount of power generation.

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

Automatic Generation Method of Exceptional Test Cases for improving User Requirement Quality on Broadcast Receiver Software (방송 수신 소프트웨어의 사용자 요구 품질 향상이 가능한 예외상황 테스트케이스 자동생성 기법)

  • Choi, In-Hwa;Cho, Min-Ju;Paik, Jong-Ho;Hwang, Jun
    • Journal of Broadcast Engineering
    • /
    • v.17 no.3
    • /
    • pp.529-539
    • /
    • 2012
  • Testing is an important part of quality control in the software life cycle. One of the most important issues in the software testing is to generate the appropriate test cases. Generally, the software can be tested based on product understanding. However, it is not easy to create test cases that can ensure the quality of the software according to the clients' request. Especially, it is difficult to create test cases for abnormal or exceptional situations. In this paper, we present a novel approach to generate exceptional test cases at the design level of UML model. Furthermore, we describe the results of actual experiment where DAB(Digital Audio Broadcasting) parsing program is tested with previous method and also with the proposed method. The results implies that our proposed method of generating test cases for exceptional situations detect more faults than that of previous method by 7.08%.

Analysis of Geometric and Spatial Image Quality of KOMPSAT-3A Imagery in Comparison with KOMPSAT-3 Imagery

  • Erdenebaatar, Nyamjargal;Kim, Jaein;Kim, Taejung
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.1
    • /
    • pp.1-13
    • /
    • 2017
  • This study investigates the geometric and spatial image quality analysis of KOMPSAT-3A stereo pair. KOMPSAT-3A is, the latest satellite of KOMPSAT family, a Korean earth observation satellite operating in optical bands. A KOMPSAT-3A stereo pair was taken on 23 November, 2015 with 0.55 m ground sampling distance over Terrassa area of Spain. The convergence angle of KOMPSAT-3A stereo pair was estimated as $58.68^{\circ}$. The investigation was assessed through the evaluation of the geopositioning analysis, image quality estimation and the accuracy of automatic Digital Surface Model (DSM) generation and compared with those of KOMPSAT-3 stereo pair with the convergence angle of $44.80^{\circ}$ over the same area. First, geopositioning accuracy was tested with initial rational polynomial coefficients (RPCs) and after compensating the biases of the initial RPCs by manually collected ground control points. Then, regarding image quality, relative edge response was estimated for manually selected points visible from two stereo pairs. Both of the initial and bias-compensated positioning accuracy and the quality assessment result expressed that KOMPSAT-3A images showed higher performance than those of KOMPSAT-3 images. Finally, the accuracy of DSMs generated from KOMPSAT-3A and KOMPSAT-3 stereo pairs were examined with respect to the reference LiDAR-derived DSM. The various DSMs were generated over the whole coverage of individual stereo pairs with different grid spacing and over three types of terrain; flat, mountainous and urban area. Root mean square errors of DSM from KOMPSAT-3A pair were larger than those for KOMPSAT-3. This seems due to larger convergence angle of the KOMPSAT-3A stereo pair.