• Title/Summary/Keyword: Automatic Water Sampling

Search Result 26, Processing Time 0.027 seconds

Characteristics and Combined Sewer Overflows (합류식 하수관거의 유출 특성 분석 조사)

  • An, Ki-Sun;Jang, Sung-Ryong;Kwon, Young-Ho
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.747-753
    • /
    • 2010
  • It follows in quality and sewage exclusion method of the investigation objective sector and the Combined Sewer Overflows which is suitable in regional characteristics and the confluence area against the rainfall initially a flow and the medulla and measurement - it analyzes the initial rainfall outflow possibility control plan which is suitable in the domestic actual condition and it proposes the monitor ring plan for the long-term flow and pollution load data accumulation. From the research which it sees the Infiltration water/Influent water and CSOs investigation it passes by the phase of hazard chain and Namwon right time 4 it does not hold reverse under selecting, Measurement it used the hazard automatic flow joint seal Sigma 910 machine and in case 15 minute interval of the I/I, it measured a flow at case 5, 15 minute standing of the CSOs. The water quality investigation for the water leakage investigation of the I/I and the sewage from the point which is identical with flow measurement during on-the-spot inspection duration against 6 items which include the BOD sampling and an analysis, when the rainfall analysis for CSOs fundamental investigation analyzed against 18 items which include the BOD sampling. Consequently, for the optimum interpretation invasion water / inflow water of the this investigation area day average the lowest flow - water quality assessment veterinarian optimum interpretation hazard average per day - lowest flow - it averages a medulla evaluation law department one lowest flow evaluation technique and it selects, it presentation collectively from here it gets, position result with base flow analysis of invasion water / inflow water.

A Study on the Fuzzy Controller for an Unmanned Surface Vessel Designed for Sea Probes

  • Park, Soo-Hong;Kim, Jong-Kwon;Lee, Won-Boo;Jang, Cheol-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.586-589
    • /
    • 2005
  • Recently, the applications of unmanned system are steadily increasing. Unmanned automatic system is suitable for routine mission such as reconnaissance, environment monitoring, resource conservation and investigation. Especially, for the ocean environmental probe mission, many ocean engineers had scoped with the routine and even risky works. The unmanned surface vessel designed for sea probes can replace the periodic and routine missions such as water sampling, temperature and salinity measuring, etc. In this paper, an unmanned surface vessel was designed for ocean environmental probe missions. A classical and an adaptive fuzzy control system were designed and tested for the unmanned surface vessel. The design methodologies and performance of the surface vessel and fuzzy control algorithm were illustrated and verified with this unmanned vessel system designed for sea probes.

  • PDF

Fish Monitoring through a Fish Run on the Nakdong River using an Acoustic Camera System (음향카메라시스템을 이용한 낙동강어도의 어류모니터링)

  • Yang, Yong-Su;Bae, Jae-Hyun;Lee, Kyoung-Hoon;Park, Jung-Su;Sohn, Byung-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.6
    • /
    • pp.735-739
    • /
    • 2010
  • This study investigated a method for monitoring fishes immigrating to upper streams from the sea in relation to water level with elapsed time, and measured fish behavior patterns and swimming speed in a fishing boat gateway using an acoustic camera system. This method was employed due to difficulties, linked to high turbidity, of using only underwater optical systems for monitoring fish migrating to brackish water. Results showed that fish length distribution showed high correlation between haul sampling and an automatic counting algorithm supported by the DIDSON software program. These results will help to maximize the effects of fish run management by increasing understanding of the amount of major fish species migrating in relation to durable water levels.

Development of Operation System for Unmaned Automatic Navigation Vehicle for Water Quality Sampling (자율항법 자동수질측정 무인선박장치 운영시스템 개발)

  • Kim, Jin-Taek;Yun, Dong-Koun;La, Min-Chul
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2012.05a
    • /
    • pp.442-442
    • /
    • 2012
  • 농업용저수지 수질측정 현황은 17,600여 개소 농업용저수지 중 농업용수 수질측정망 조사시설은 저수지 800개소이며, 농업용 호소로서 환경부 조사 시행 호소수질측정망시설 26개소(저수지 16개소, 담수호 10개소)를 포함한 826개소를 대상으로 농업용수 수질을 분석 평가하고 있다. 저수지 자율항법 자동수질측정을 위하여 개발한 운영시스템은 내용적측정 무인탐사선과의 연계운항 제어모듈 개발 및 저수지 수질측정을 위한 최적항로 운항모듈을 개발하였다. 자율항법 무인탐사선의 자동수질 측정을 위한 운항 제어 알고리즘 설계를 위하여 기존의 자율항법 탐사선의 운항 알고리즘과 수질자동 측정장치 제어 알고리즘을 분석하여 연계 제어모듈을 설계하고 프로그래밍 하였다. 운영과정은 선박운영 프로그램에서 수질모니터링 프로그램으로 Operation Start 명령을 전송하면 수질모니터링 프로그램에서 이 명령을 수신한 이후에 윈치제어 및 수질측정, 각 해당 수심에서 시료채수를 수행한 이후에 Opeartion End 신호를 선박운영 프로그램에 전송하면 다음 지점으로 이동할 수 있도록 하였다. 이를 통하여 효율적인 농업용저수지의 무인자동 수질측정 및 채수기술을 개발 제공하도록 하겠다.

  • PDF

Water Saving Irrigation Manual of House Red Pepper for the Northern Region of Korea (우리나라 북부권역 시설재배 고추의 물절약형 관개 기준 설정 연구)

  • Eom, Ki-Cheol;Park, So-Hyun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.312-316
    • /
    • 2012
  • Very important factor for crop cultivation are water, nutrient and temperature. However, the essential factor for crop cultivation is water management. Water management is the most important and difficult problems in crop cultivation. The water saving irrigation manual can be used with easy to the farmer and who want automatic irrigation without soil sampling and any kinds of sensors measuring soil water status. The water requirement of red pepper cultivated in plastic film house is different according to soil texture, area as well as climate condition and growth stage. And, the measurement of potential evapo-transpiration (PET) and crop coefficient (Kc) to decide optimum irrigation schedule is very difficult. Results : The average PET during 30 years of northern region of korea for the red pepper cultivation was a $2.31mm\;day^{-1}$. The water saving irrigation manual as water saving is possible, those irrigation interval and amount of irrigation according to growing season and soil texture, are developed using the lysimeter experiments carried out by the RDA for 11 years about potential evapo-transpiration, Kc for the northern region of korea.

Experimental Study on Temperature Dependence of Nitrate Sensing using an ISE-based On-site Water Monitoring System

  • Jung, Dae-Hyun;Kim, Dong-Wook;Cho, Woo Jae;Kim, Hak-Jin
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.122-122
    • /
    • 2017
  • Recently, environmental problems have become an area of growing interests. In-situ monitoring of water quality is fundamental to most environmental applications. The accurate measurement of nitrate concentrations is fundamental to understanding biogeochemistry in aquatic ecosystems. Several studies have reported that one of the most feasible methods to measure nitrate concentration is the use of Ion Selective-electrodes (ISEs). The ISE application to water monitoring has several advantages, such as direct measurement methodology, high sensitivity, wide measurement range, low cost, and portability. However, the ISE methods may yield inconsistent results where there was a difference in temperature between the calibration and measurement solutions, which is associated with the temperature dependence of ionic activity coefficients in solution. In this study, to investigate the potential of using the combination of a temperature sensor and nitrate ISEs for minimizing the effect of temperature on real-time nitrate sensing in natural water, a prototype of on-site water monitoring system was built, mainly consisting of a sensor chamber, an array of 3 ISEs, an waterproof temperature sensor, an automatic sampling system, and an arduino MCU board. The analog signals of ISEs were obtained using the second-order Sallen-key filter for performing voltage following, differential amplification, and low pass filtering. The performance test of the developed water nitrate sensing system was conducted in a monitoring station of drinking water located in Jeongseon, Kangwon. A temperature compensation method based on two-point normalization was proposed, which incorporated the determination of temperature coefficient values using regression equations relating solution temperature and electrode signal determined in our previous studies.

  • PDF

A Study on the Performance Optimization of a Continuous Monitoring Method for Hazardous VOCs in the Ambient Atmosphere (환경대기 중 유해성 VOC에 대한 자동연속 측정방법의 성능 최적화에 관한 연구)

  • Son, Eun-Seong;Seo, Young-Kyo;Lee, Dong-Hyun;Lee, Min-Do;Han, Jin-Seok;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.6
    • /
    • pp.523-538
    • /
    • 2009
  • Recently, there has been a keen demand for real-time automatic monitoring of VOCs not only in Korea but other developed countries. We carried out this study to evaluate and to optimize the performance of a continuous automatic monitoring system for hazardous VOCs (HVOCs) in the ambient atmosphere, using an on-line GC system. The online system normally consisted of a Nafion dryer prior to a cold trap of an automatic thermal desorption apparatus and a GC system equipped with two detectors, i.e. PID and ECD. Preliminary tests conducted to check out any contamination of the system revealed an evidence of significant artifact formation of benzene, and it was found that the Nafion dryer (even brand new one) is the source of the benzene artifact. Thus, all the subsequent experiments in this study was carried out inevitably by removing the Nafion dryer. The on-line GC method was investigated with a variety of QC/QA performance criteria such as repeatability, linearity, lower detection limits, and accuracy. In order to find out the best operating condition for the on-line GC system, three different types (in terms of adsorption strength) of cold trap combinations were tested, i.e. (i) Tenax-TA and Carbopack-B combination (weak and hydrophobic); (ii) Tenax-TA, Carbopack-X and Carboxen-1000 combination (strong and hydrophilic); and (iii) Tenax-TA and Carbopack-X combination (medium and hydrophobic/hydrophilic). The USEPA TO-17 manual method was selected as a reference method to evaluate the performance of the on-line method. A series of experiments revealed that the system performance was superior to others when a cold trap packed with hydrophilic adsorbents (Tenax-TA/Carbopack-X/Carboxen-1000 combination) was used and operated at $25^{\circ}C$. However, the system with a cold trap packed with a combination of Tenax-TA and Carbopack-X is more recommended for field applications since the carboxen-1000 adsorbent is too sensitive to water vapor, and hence the performance of the system might be very unstable to humid samples or during rainy days. Furthermore, the precision and accuracy criteria of the Tenax-TA/ Carbopack-X combination were generally compatible with the triple adsorbents cold trap. The continuous automatic monitoring method is, thus, considered very useful to real-time monitoring to understand the variations of VOCs concentrations in ambient air, as it adopts much simpler procedures in sampling, analysis, and data integration steps than manual monitoring methods. However, it should be noted that there is a high possibility of benzene artifacts formation through the Nafion dryer, which is often installed to remove water vapor in air samples before being adsorbed onto the cold trap. Therefore, if a Nafion dryer is used in any studies of monitoring VOCs, the benzene contamination should be carefully examined before carrying out obtaining the data.

HyperSAS Data for Polar Ocean Environments Observation and Ocean Color Validation (극지 해양환경 관측 및 고위도 해색 검보정을 위한 초분광 HyperSAS 자료구축)

  • Lee, Sungjae;Kim, Hyun-cheol
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_2
    • /
    • pp.1203-1213
    • /
    • 2018
  • In Arctic and Antarctic ocean, remote sensing is the most effective observation for environmental changes due to the inaccessibility of the regions. Even though satellite, UAV (Unmanned Aerial Vehical) are well known remote sensing platforms, and research vessel also used for automatic measurement on the regions, varied environment of Polar regions require time series and wide coverage of data. Especially, in high latitude, apply an optical satellite remote sensing is not easy due to low sun altitude. In this paper, we introduce an operation of hyper-spectrometer (HyperSAS/Satlantic inc.) which is mounted on Ice Breaker Research Vessel ARAON of Korea Polar Research Institute since 2010, to acquire an above water reflectance atomatically through every research cruise on Arctic and Antarctic ocean and transit both regions. In addition to, auxiliary data for the remotely acquired data, in situ water sampling were also obtained. The above water reflectance and in situ water sampling data are continuously acquired since 2010 will contribute to improve an Ocean Color algorithm in the high latitude and help to understand ocean reflectances over from high latitude through low latitude. Preliminary result from above water reflectance showed characteristics of Arctic ocean and Antarctic Ocean and used to develop algorithms for estimating various ocean factors such as chlorophyll and suspended sediment.

Understanding the Groundwater System through the Long-term Monitoring - a case Study of Gwangneung Headwater Catchment (장기모니터링을 통한 지하수계의 이해 - 광릉소유역 사례 연구)

  • Lee, Jae-Min;Woo, Nam-C.
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.51-62
    • /
    • 2012
  • Effects of climate change on groundwater system requires understanding the groundwater system in temporal and spatial scales through the long-term monitoring. In this study, the spatio-temporal variations of groundwater were analyzed through the continuous observation of water level, electrical conductivity (EC) and water temperature with automatic data-loggers and sampling in a Gwangneung catchment, Korea, for the four years from 2008 to 2011. Groundwater monitoring were performed at the nest-type wells, MW1 and MW2, located in upsteam and downstream of the catchment, respectively. During the survey period, both the total amount of annual precipitation and the frequency of concentrated rainfall have increased resulting in the elevation of runoff. Water level of MW1 showed no significant fluctuations even during the rainy season, indicating the confined groundwater system. In contrast, that of MW2 showed clear seasonal changes, indicating the unconfined system. The lag-time of temperature at both wells ranged from one to three months depending on the screened depths. Results of chemical analyses indicated that major water compositions were maintained constantly, except for the EC decreases due to the dilution effect. Values of the stable-isotope ratios for oxygen and deuterium were higher at MW2 than MW1, implying the confined system at the upstream area could be locally developed.

Compositional analysis by NIRS diode array instrumentation on forage harvesters

  • Andreashaeusler, Michael Rode;Christian, Paul
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1619-1619
    • /
    • 2001
  • Ourwork aims to assess the content of dry matter, protein, cell wall parameters and water soluble carbohydrates in forages without having to handle samples, transport them to a laboratory, dry, grind and chemically analyze them. for this purpose, the concept of fresh forage analysis under field conditions by means of compact integrated NIRS InGaAs-diode array instruments on small plot harvesters is being evaluated for plant breeding trials. This work was performed with the world first commercial experimental forage plot harvester equipped with a NIRS module for the collection, compression, and scanning of forage samples (including automatic referencing and dark current measure ments). It was used for harvesting and analyzing a number of typical forage grass and forage legume plot trials. After NIRS measurements in the field each sample was again analyzed in the laboratory by means of a conventional grating spectrometer equipped with Si-and PbS-detectors. Conventional laboratory analysis of the samples was restricted to dry matter (DM) content by means of oven drying at 105. Routine chemometric procedures were then employed to assess the comparative accuracy and precision of the DM assessments in the spectral range between 950 and 1650nm by the NIRS diode array as well as by the conventional NIRS scanning instrument. The results of this study confirmed that the type of NIRS diode array instrument employed here functioned well even in rugged field operations. further refinements proved to be necessary for optimizing the automatic filling of the sample compartment to adjust for the wide variation in forage material under conditions of extremely low or high harvest yields. The error achieved in calibrating the apparatus for forages of typical DM content proved to be satisfactory (SECV < 1.0). Possibly as a consequence of higher sampling errors, its performance in atypical forages with elevated DM contents was less satisfactory. The error level obtained on the conventional grating NIR spectrometer was similar to that of the diode array instrument for both types of forage.

  • PDF