광범위 입력전압을 갖는 준공진형 플라이백 파워서플라이의 연구 (A Study of Quasi-Resonant Flyback Power Supply with Very Wide Input Voltage)

  • 이용근;나재두
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.143-145
    • /
    • 2015
  • One of the many problems besetting the converter designer is being able to design a switching power supply that can operate in the range of very wide input voltage. Specially, in an emergency diesel generator system, the AVR(Automatic Voltage Regulator) is a regulator which regulates the output voltage of the generator at a nominal constant voltage level. In addition, the AVR must be operated in very wide input voltage. Therefore, a power supply for the AVR must be operated at the very wide input voltage range. In this paper, a quasi-resonant flyback power supply with very wide input voltage range is proposed. Also, the performance of the proposed power supply is demonstrated through experiments.

매우 넓은 입력전압 범위를 갖는 스위치모드 플라이백 파워서플라이에 대한 연구 (Study of Flyback Switching Power Supply With Very Wide Input Voltage Range)

  • 나재두;이춘택;박형남;이용근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1008-1009
    • /
    • 2015
  • An emergency diesel generator system is an independent source of power that supports important electrical systems on loss of normal power supply. AVR(Automatic Voltage Regulator) is a regulator which regulates the output voltage at a nominal constant voltage level. Specially, a power supply for the AVR must be operated at the very wide input range. In this paper, a flyback power supply with very wide input voltage range is proposed.

  • PDF

PM동기발전기의 전압강하 보상기 (Voltage restorers of PM synchronous generator)

  • 정승태;이준호;이화춘;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.512-513
    • /
    • 2010
  • 최근 일정전압의 신뢰성 있는 전원공급 장치의 개발에 대한 필요성이 날로 증가하고 있다. 기존의 AVR(Automatic Voltage Regulator)은 디지털식이므로 고장시 수리하는데 많은 어려움이 있지만 기계식AVR은 고장시 즉각 대처 할 수 있기 때문에 신뢰성 있는 전원공급 장치로 볼 수 있다. 본 논문에서는 PM(Permanent Magnet)동기발전기에 부하가 걸렸을 때 전원이 리액턴스로 인한 전압강하가 생기므로 기계식AVR을 이용하여 보상하고자한다. SVR(Slidac Voltage Regulator)형 자동전압장치와 절연변압기를 이용하여 기계식AVR을 설정하는 방법을 제시하고 PM동기발전기와 연결하여 전압강하를 보상하는 시뮬레이션을 통하여 검증하였다.

  • PDF

AVR 마이크로콘트롤러의 특성 및 응용 기술

  • 윤덕용
    • 전력전자학회지
    • /
    • 제9권2호
    • /
    • pp.15-22
    • /
    • 2004
  • 요즈음 AVR이 뜨고 있다. 전기기술 분야에서는 AVR이라고 하면 보통 자동전압조정기 (Automatic Voltage Regulator)를 지칭하지만, 마이크로프로세서 시장에서 AVR이라고 하면 Atmel사의 작지만 강력한 8비트 RISC 마이크로콘트롤러 시리즈를 지칭한다. 1984년에 설립된 미국의 신생 반도체 회사인 Atmel에서 1997년에 처음 발표하여 불과 7년 정도의 짧은 역사를 가지고 있는 AVR이 시장에서 기라성 같은 선배 제품들을 속속 물리치고 강세를 보이는 괴력을 발휘하고 있다.(중략)

과도 응답 보상기를 가지는 동기발전기의 고성능 여자 제어시스템 (A Performance Improvement of Exciter Control System of Synchronous Generator using Transient Response Compensator)

  • 이동희;왕혜군;김태형;안진우
    • 조명전기설비학회논문지
    • /
    • 제21권5호
    • /
    • pp.82-89
    • /
    • 2007
  • 여자제어 시스템의 AVR(Automatic Voltage Regulator) 장치는 발전기의 출력 전압을 일정하게 유지시키기 위하여, 여자기의 전압 또는 전류를 발전기 부하 전류 및 전압 변동에 따라 제어하는 역할을 수행한다. 이러한 AVR 장치의 응답성과 제어 특성은 발전기의 부하 변동 또는 과도 응답 상태에서의 출력 특성을 결정하게 된다. 본 논문에서는 고성능 전동기 제어 시스템에 널리 사용되고 있는 PWM 제어 시스템과 부하 변동에 강인하게 동작할 수 있는 과도 응답 보상기를 적용한 고성능 여자 시스템을 제안한다. 과도 응답 보상기는 발전기의 부하 전류 변동에 따라, 여자기의 제어신호를 PID 제어기의 출력에 더하여 빠른 속응성과 안정성을 가지도록 함으로써, 발전기의 출력 전압을 안정적으로 공급할 수 있도록 제어한다. 제안된 고성능 여자 시스템은 컴퓨터 시뮬레이션과 소형 발전기 시스템에 적용된 실험을 통하여 그 성능을 검증하였다.

브러쉬리스 동기발전기 자동전압조정기의 제어성능 향상을 위한 연구 (A study on improvement of the control performance of the automatic voltage regulator of a brushless synchronous generator)

  • 이영찬;김종수;정병건
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권7호
    • /
    • pp.909-915
    • /
    • 2014
  • 선박과 육상용 브러쉬리스 동기발전기의 자동전압조정기는 출력 단자전압을 주로 PID 제어방식으로 제어한다. 하지만 발전기 전력계통에서 부하의 변화량과 변화횟수가 클 경우에는 PID 제어방식으로는 전압의 변화량과 정정시간에 대해 강인한 제어성능을 발휘하기 어려워진다. 본 논문에서는 PID 제어방식에 비해 기준 단자전압 값에 대한 추종성능이 우수한 퍼지제어방식을 사용하여 자동전압조정기의 발전기 단자전압을 조정하는 기법을 제안하였으며, MATLAB/SIMULINK 시뮬레이션을 통해 동기발전기 자동전압 조정성능에 대한 우수성을 입증하였다.

내연기관 구동 비상용 브러시리스형 동기발전기의 과도특성 개선 (Improvement of Transient Characteristics of Brush-less Type Synchronous Generator for Emergency Driven by Internal-Combustion Engine)

  • 안영주
    • 전기학회논문지P
    • /
    • 제65권4호
    • /
    • pp.268-272
    • /
    • 2016
  • A brush-less type synchronous generator is driven by an internal-combustion engine that is used for emergency source. This kind of generator has to maintain output voltage in a range of some degree under the abrupt load irregular conditions such as a full load trip. This paper suggests a suppression method of increasing the output voltage over the rating. Automatic voltage regulator detects excessive rising of output voltage of the generator and supplies the signals to a switch installed in the rotating exciter through the photo-coupler. The current of main field rapidly decreases by additional resistor of the main filed circuit. Therefore, the output voltage of the generator is maintained effectively. The experimental results verified that the excessive value of the output voltage is limited in the range of 7% of the rated voltage.

PMG Type 디지털 AVR을 이용한 선박용 동기발전기 출력전압제어 (Voltage Control of Synchronous Generator for Ships using a PMG Type Digital Automatic Voltage Regulator)

  • 유동환;박상훈;원충연;유재성;이상석;안성준
    • 전력전자학회논문지
    • /
    • 제14권1호
    • /
    • pp.38-45
    • /
    • 2009
  • 일정 출력을 얻기 위해 동기발전기 계자 여자는 AVR에 의해 제어된다. 대부분의 선박용 동기발전기 AVR은 사이리스터 위상제어 방식을 사용한다. 하지만 이 방식은 제어 주기가 MOSFET이나 IGBT로 구성된 컨버터에 비해 느리므로 속응 제어를 구현하는데 어려움이 있다. 따라서 본 논문에서는 선박용 동기발전기에 MOSFET을 사용한 PMG형 디지털 AVR을 구현하였다. PMG형 디지털 AVR 회로 구성은 간단하고 단락 시 발전기 출력전압이 영으로 되어 AVR이 동작하지 못하므로 출력전류를 여자회로로 흐르도록 하는 CBC가 요구된다. 본 논문에서 연구된 여자 시스템은 실제 선박용 발전기를 대신하여 10[kVA]급 프로토타입의 실험을 통하여 시스템의 타당성을 검증하였다.

CTTS의 비동기 절체 시 조속기 제어를 통한 과도 개선에 관한 연구 (Study on Transient Improvement through Governor Control under Asynchronous Transition of CTTS)

  • 강병욱;채희석;한운기;임현성;권승옥;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.47-52
    • /
    • 2015
  • This paper derives the problems that occur when asynchronous transfer in case of phase, frequency, voltage between the emergency generator and the grid and proposed the countermeasure to solve this problem when the transfer switch replace ATS(Automatic Transfer Switch) with CTTS(Closed Transition Transfer Switch) for the non-interrupting switching. In order to simulate above cases, modelling was used the transient analysis program PSCAD/EMTDC. By using this, the customer installed emergency generator and the grid was implemented. We compared three cases of asynchronous transition based on the basic case and proposed improvement by controlling the governor of emergency generator.

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF