• Title/Summary/Keyword: Automatic Test Equipment

Search Result 189, Processing Time 0.027 seconds

A study on the Development of Smoke Detector Sensitivity Test Equipment (휴대용 연기감도시험기 개발에 관한 연구)

  • Kim, Hyeong-Gweon;Kwon, Seong-Pil;Yoon, Hun-Ju;SaKong, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.125-132
    • /
    • 2009
  • In this study we could contribute to the development of a precise checking tool with which the reliability of the automatic fire detection systems was enhanced and the safety of the people was ensured. In the same way as the domestic technical standard, the portable smoke sensitivity tester, which was developed in this work, could be used to check the capability of the smoke detectors installed in the field. Its heater inside was warmed up to $400^{\circ}C$ in 40 seconds and the paper as a smoke source was burned to produce smoke for the test. With the Photoelectric smoke detector it was possible to measure and control the smoke concentration in a range from 0%/m to 25%/m. With the adjustment of rpm of the fan, it was possible to keep a constant wind velocity in a range from 20cm/sec to 40cm/sec.

Unmanned Multi-Sensor based Observation System for Frost Detection - Design, Installation and Test Operation (서리 탐지를 위한 '무인 다중센서 기반의 관측 시스템' 고안, 설치 및 시험 운영)

  • Kim, Suhyun;Lee, Seung-Jae;Son, Seungwon;Cho, Sungsik;Jo, Eunsu;Kim, Kyurang
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.24 no.2
    • /
    • pp.95-114
    • /
    • 2022
  • This study presented the possibility of automatic frost observation and the related image data acquisition through the design and installation of a Multiple-sensor based Frost Observation System (MFOS). The MFOS is composed of an RGB camera, a thermal camera and a leaf wetness sensor, and each device performs complementary roles. Through the test operation of the equipment before the occurrence of frost, the voltage value of the leaf wetness sensor increased when maintaining high relative humidity in the case of no precipitation. In the case of Gapyeong- gun, the high relative humidity was maintained due to the surrounding agricultural waterways, so the voltage value increased significantly. In the RGB camera image, leaf wetness sensor and the surface were not observed before sunrise and after sunset, but were observed for the rest of the time. In the case of precipitation, the voltage value of the leaf wetness sensor rapidly increased during the precipitation period and decreased after the precipitation was terminated. In the RGB camera image, the leaf wetness sensor and surface were observed regardless of the precipitation phenomenon, but the thermal camera image was taken due to the precipitation phenomenon, but the leaf wetness sensor and surface were not observed. Through, where actual frost occurred, it was confirmed that the voltage value of leaf wetness sensor was higher than the range corresponding to frost, but frost was observed on the surface and equipment surface by the RGB camera.

A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer (재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究))

  • Jung, Ha-Chung
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

A Development of Welding Information Management and Defect Inspection Platform based on Artificial Intelligent for Shipbuilding and Maritime Industry (인공지능 기반 조선해양 용접 품질 정보 관리 및 결함 검사 플랫폼 개발)

  • Hwang, Hun-Gyu;Kim, Bae-Sung;Woo, Yun-Tae;Yoon, Young-Wook;Shin, Sung-chul;Oh, Sang-jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.2
    • /
    • pp.193-201
    • /
    • 2021
  • The welding has a high proportion of the production and drying of ships or offshore plants. Non-destructive testing is carried out to verify the quality of welds in Korea, radiography test (RT) is mainly used. Currently, most shipyards adopt analog-type techniques to print the films through the shoot of welding parts. Therefore, the time required from radiography test to pass or fail judgment is long and complex, and is being manually carried out by qualified inspectors. To improve this problem, this paper covers a platform for scanning and digitalizing RT films occurring in shipyards with high resolution, accumulating them in management servers, and applying artificial intelligence (AI) technology to detect welding defects. To do this, we describe the process of designing and developing RT film scanning equipment, welding inspection information integrated management platform, fault reading algorithms, visualization software, and testing and verification of each developed element in conjunction.

Changes of the Chemical and Microbiological Quality in Milk from Jeju-Do after Raw Milk Grading System (등급제 실시 이후 제주산 원유의 품질 변화)

  • Lee, Hyun-Jong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • This experiment was performed to identify the improvement of raw milk quality after introducing raw milk grading system(1993, June). The purpose of this experiment was to investigate chemical component and microbiological quality of raw milk in jeju. This experiment made it possible to spread high standard of quality of raw milk or milk product including yoghurt, ice cream etc., and to provide dairy industry information for the construction of Jeju international free city master plan. As a result, automatic milking system is improved a lot after introducing raw milk grading system and sustained good condition compared with other provinces. High ratio was shown dairy farm in jeju for pre-milking, pre-cooling system equipment and self laboring. Otherwise, the ratio of dairy farm doing test of mastitis is low. The ratio of first grade distribution in Jeju is 80.64%, which means that was improved before introducing raw milk grading system. The number of somatic cells found in summer more than that of other seasons in raw milk. However, these data is a little higher than the nation wide data medium. Also, general components, annual lipid ratio is 3.90% that improved compared with before introducing raw milk grading system. These data showed low in summer and similar to nation wide.

  • PDF

Remote Secure Entrance Control System using RFID and TCP/IP (RFID와 TCp/IP를 활용한 원격 보안 출입 제어 시스템)

  • Kim, Jeong-Sook;Kim, Cheon-Shik;Yoon, Eun-Jun;Hong, You-Sik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.45 no.6
    • /
    • pp.60-67
    • /
    • 2008
  • At present, RFID system is highly welcomed as a substitute system with its bar code recognition system and self recognition equipment. Consequently, the system has multi applications and can be complementing to its security. In particular, RFID system is significantly related with electronic transaction equipments : transportation card, ID card in check point, attendance sheet. Based upon these characteristic, the system is becoming extremely popular in the field of logistics, harbor and stock management, animal control and product circulation & distribution. In this dissertation, I would like to present a more efficient and stable remote entry control system with the network-based TCP/IP. It is a simple example of ubiquitous computing function. Above all, approved protocol system should be applied to the remote entry control function. Its efficient function with the applied approval protocol based-remote entry control system should be confirmed. Therefore, a preliminary test should be prerequisite in automatic entrance function with the embedded and TCP/IP-based RFID system.

Development of a voyage performance monitoring system based on ENC for small and medium-sized vessels (전자해도 기반 중소형선박 항해 성능 모니터링 시스템 개발)

  • Lee, Kwangkook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1615-1622
    • /
    • 2016
  • This research aims to develop a voyage performance monitoring system based on international standards. The developed system is equipped with an electronic navigational chart(ENC) that provides onshore and offshore information, as well as supports standardized interfaces with navigational equipment, such as a gyro compass, a differential global positioning system(DGPS), and an automatic identification system(AIS), to monitor the navigation route in real time. In addition, the proposed system adopts a car navigation system to provide a graphical user interface, an intuitive menu-driven configuration, and an easy guide for safer sea navigation. The system, interfaced with the gyro compass and DGPS, was verified without any data loss, and passed a test conducted under extreme conditions by the Korea Laboratory Accreditation Scheme(KOLAS). Finally, the system contributes to preventing collision of vessels and minimizing casualties by maximizing the convenience of mariners which a conventional system does not provide.

A Study on the Characteristics of High Temperature and Mechanisms for Creep Deformation of AZ31 Mg Alloy (AZ31마그네슘 합금의 고온특성 및 크리이프 변형기구에 관한연구)

  • Kang, D.M.;An, J.O.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.96-101
    • /
    • 2005
  • Magnesium alloys have been widely used for many structural components of automobiles and aircraft because of high specific strength and good cast ability in spite of hexagonal closed-packed crystal structure of pure magnesium. In this study, uniaxial tension tests at high temperature and creep tests are done in order to investigate the characteristics of high temperature and mechanisms for creep deformation of AZ31 Mg alloy. Yield stress and ultimate tensile stress decreased with increasing temperature, but elongation increased from results of uniaxial tension test at high temperature. The apparent activation energy Qc, the applied stress exponent n and rupture life have been determined during creep of AZ31 Mg alloy over the temperature range of 473K to 573K and stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller, whose data are sent to computer. At around the temperature of $473K{\sim}493K$ and under the stress level of $62.43{\sim}93.59%MPa$, and again at around the temperature of $553K{\sim}573K$ and under the stress level of $23.42{\sim}39.00MPa$, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy for the creep deformation was nearly equal, respectively, and a little low to that of the self diffusion of Mg alloy including aluminum. Also rupture surfaces at high temperature have had bigger dimples than those at lower temperature by SEM.

  • PDF

FPGA Implementation of VME System Controller (VME 시스템 제어기의 FPGA 구현)

  • Bae, Sang-Hyun;Lee, Kang-Hyeon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.11
    • /
    • pp.2914-2922
    • /
    • 1997
  • For FA (factory automation) and ATE (automatic test equipment) in the industrial area, the standard bus needs to increase the system performance of multiprocessor environment. VME(versa module european package format) bus is appropriated to the standard bus but has features of small package and low board density. Beside, the density of board and semiconductor have grown to become significant issues that affect development time, project cost and field diagnostics. To fit this trend, in this paper, we composed Revision C.1 (IEEE std. P1014-1987) of the integrated environment for the main function such as arbitration, interrupt and interface between, VMEbus and several control modules Also the designed, VME system controller is implemented on FPGA that can be located even into slot 1. The control and function modules are coded with VHDL mid-fixed description method and then those operations are verified by simulation. As a result of experiment, we confirmed the most important that is the operation of Bus timer about Bus error signal should occur within $56{\mu}m$, and both control and function modules have the reciprocal operation correctly. Thus, the constructed VHDL library will be able to apply the system based VMEbus and ASIC design.

  • PDF

Transmission Efficiency of Dual-clutch Transmission in Agricultural Tractors (농업용 트랙터 듀얼 클러치 변속기의 동력전달 효율 분석에 관한 연구)

  • Moon, Seok Pyo;Moon, Sang Gon;Kim, Jae Seung;Sohn, Jong Hyeon;Kim, Yong Joo;Kim, Su Chul
    • Journal of Drive and Control
    • /
    • v.19 no.1
    • /
    • pp.43-50
    • /
    • 2022
  • The aim of this study was to conduct basic research on the development of a dual-clutch transmission(DCT) and automatic transmission for agricultural tractors. The DCT layout and the DCT simulation model were developed using commercial software. Power transmission efficiency of the DCT and component power loss were analyzed to verify the developed simulation model. Power loss analysis of the components was conducted according to previous studies and ISO(International Organization for Standardization) standards. The power transmission efficiency of the DCT simulation model was 68.4-91.5% according to the gear range. The power loss in the gear, bearing, and clutch DCT system components was 0.75-1.49 kW, 0.77-2.99 kW, and 5.24-10.52 kW, respectively. The developed simulation model not include the rear axle, differential gear, final reduction gear. Therefore actual power transmission efficiency of DCT will be decreased. In a future study, an actual DCT can be developed through the simulation model in this study, and optimization design of DCT can be possible by comparing simulation results and actual vehicle test.