• Title/Summary/Keyword: Automatic Switching System

Search Result 83, Processing Time 0.033 seconds

Design and Implementation of the Automatic cable assembly test system that can test cable assembly effectively

  • Jang, Ki-Mang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.7
    • /
    • pp.1-10
    • /
    • 2018
  • In this paper, we propose the principles and design details of Automatic cable assembly test system and show its utility. Testing the cable assembly is required periodically or non-periodically in the system that the cable assembly performance is quite important like military equipment. There are several weaknesses when humans test the cable assembly manually. It not only takes much time but also could happen human error. To improve these disadvantages, I developed Automatic cable assembly test system. The system can be implemented by building switching control system that connect and disconnect the cable assembly and measuring devices. Through the result of the cable assembly test with this test system, we show this system makes test time short and improves of test reliability as compared with manual test.

Automatic Switching System for The Impedance Analysis of Multichannel icroelectrode Arrays: Limits and Improvement Scheme (다채널 미세전극칩 임피던스 분석을 위한 자동 스위칭 시스템: 한계점 및 개선 방안)

  • Lee, Seok-Young;Nam, Yoon-Key
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.207-217
    • /
    • 2011
  • Electrode impedances are measured to quantitatively characterize the electrode-electrolyte or cell-electrode interfaces. In the case of high-density microelectrode arrays(MEAs) that have been developed for brainmachine interface applications, the characterization process becomes a repeating and time-consuming task; a system that can perform the measurement and analysis in an automated fashion with accuracy and speed is required. However, due to the large number of channels, parasitic capacitance and off-capacitance components of the switching system become the major factors that decreased the accuracy for the measurement of high impedance microelectrodes. Here we investigated the implementation of automatic impedance measurement system with analyzing the causes of possible measurement-related problems in multichannel switching configuration. Based on our multi-channel measurement circuit model, we suggest solutions to the problems and introduce a novel impedance measurement scheme using electro-mechanical relays. The implemented measurement system could measure |Z| < 700 $k{\Omega}$ of impedance in - 10% errors, which can be widely applicable to high density neural recording MEAs.

Simulator of Automatic Power Switching System (절연구간 자동절체 통과 현상 규명용 모의시뮬레이터 제작)

  • Han, Moon-Seob;Shin, Hyo-Bum;Jang, Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.918-923
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper introduces a simulator that assesses efficiency of automatic power switching systems in neutral sections. The is composed of a power supply system, electric railway vehicles, thyristor switches, and traction motors.

  • PDF

A Study on the Reduction of Onboard Transformer Inrush Current of Electric Railway (전기철도 차량 내 변압기의 여자돌입전류 저감에 관한 연구)

  • Huh, Jae-Sun;Kang, Byoung-Wook;Shin, Hee-Sang;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2125-2130
    • /
    • 2010
  • The neutral section on electric railway system is significant sector in order to prevent short circuit of two electric powers. However, while electric trains pass the neutral section, those speed is decreased and the accident of AC electric traction system and the electric train would be occurred. So the countermeasures are urgently needed. The automatic power switching technology system that is current being research and development is system to improve these problems. Because main object of this system is power change using static switch in the neutral section, it's expected to cause a variety of transients. Especially, onboard transformer inrush current for electric railway train can be occurred more than rated current according to switching time. Therefore, the analysis and improvement are needed to ensure the stability of this system. In this paper, we analyze the operating characteristics of the automatic power switching technology system. Especially, it reviews inrush current according to the closing phase angle. And we propose control plan of inrush current considering the case that voltage is maintained due to counter electromotive force and regenerative braking operation of electric railway train. Finally, the proposed control scheme was reviewed using the transient analysis program.

Implementation of manual/automatic complex redundancy control method for modulation system of a paging earth station in reduntancy structure (이중화 무선호출 지구국 변조부 시스템의 수/자동 복합 이중화 제어 방법 구현)

  • 박승창;김영민
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.21-29
    • /
    • 1997
  • This paper describes implementation contents contents of manual/automatic complex redundancy control mothod for control of a modulation system of a Paging earth station in redundancy stracture. The existed redundancy control method usually is a automatic local control method in which the redundancy switching, including display or alarm beeping through operation of display devices or audio devices, is performed by the co-action of components or modules when the abnormal status is occurred in a modulation system. However, this method introduced in here is designed to enable use of three control modes;1) Manual mode by an operator, 2) Auto-remote mode by the Network Maagement System, through implementation of the redundancy control system composed of the redundancy control board and the redundancy switching circuit.

  • PDF

Development of Low-Cost Automatic Flight Control System for Unmanned Target Drone

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.367-371
    • /
    • 2004
  • This paper describes development of automatic flight control system for an unmanned target drone which is operated by Korean army as for anti-air gun shooting training. Current target drone is operated by pilot control of on-board servo motor via remote control system. Automatic flight control system for the target drone greatly reduces work load of ground pilot and can increase application area of the drone. Most UAVs being operated now days use high-priced sensors as AHRS and IMU to measure the attitude, but those are costly. This paper introduces the development of low-cost automatic flight control system with low-cost sensors. The integrated automatic flight control system has been developed by integrating combining power module, switching module, monitoring module and RC receiver as an one module. The performance of automatic flight control system is verified by flight test.

  • PDF

Development of Electronic Identification Unit Using RF (RF를 이용한 전자 개체 인식 장치 개발)

  • 조성인;류관희;안광재;김유용;유윤관
    • Journal of Biosystems Engineering
    • /
    • v.27 no.5
    • /
    • pp.459-466
    • /
    • 2002
  • In Korea, a need of automatic dairy farm management system has been increased to lower production cost and to strengthen international competition. However, the present management system was mostly relied on foreign technologies and caused some problems in post management and after-sales services. Therefore, though there is a problem of price and quality at present, domestic technologies of the management system should be developed for the long run. This study was conducted to develop an electronic identification unit for an automatic dairy farm management system. The developed system was consisted of a tag, a reader, a switching circuit, and a personal computer. The tag attachable to each individual cow was developed to transmit individual radio frequency(RF) code into the air with modulation of ASK(amplitude shift keying). And the switching circuit was added to avoid confusion on reception and transmittance. The reader attached to a feeding device was developed to transmit activating signal periodically and to identify code of the individual tag when the tag was approached to the device. The reader was consisted of an active filter, a detecter, a comparator and a microcontroller. The test result was feasible enough to apply it for the automatic farm management system and the identified maximum distance was about 37cm.

Automatic Optimum Control of the Traffic Signal Lights (교통신호의 자동최적제어에 관한 연구)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.12-16
    • /
    • 1971
  • The electrical detector and computer systems for traffic flow and speed measurement are demonstrated in this paper. For the best traffic control optimization, linear and non-linear equations in the transition state are dealing with the perturbation of the linear car-following. In the conclusions, we construct a realizable system for the central automatic traffic control with a computer. Furthermore, fixed periodic switching system by manual with the automatic traffic control system is recommended for emergency perturbation.

  • PDF

Automatic P/PI Speed Controller Design for Industry Servo Drives (산업용 서보 구동 시스템을 위한 자동 P/PI 속도 제어기 설계)

  • 배상규;석줄기;김경태;이동춘
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.616-623
    • /
    • 2003
  • Conventional P/PI speed controller of today's servo drives should be manually tuned the controller switching set-point by trial-and-errors, which may translate the drive system down-time and loss of productivity. The adjustable drive performance is heavily dependent on the quality of the expert knowledge and becomes inadequate in applications where the operating conditions change in a wide range, i.e., tracking command, acceleration/deceleration time, and load disturbances. In this paper, the demands on simple controls/setup are discussed for industry servo drives. Analyzing the frequency content of motor torque command, P/PI control mode switching is automatically performed with some prior knowledge of the mechanical dynamics. The dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time over the whole operating conditions. For comprehensive comparison of traditional P/PI control scheme, extensive test is carried out on actual servo system.

The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW (LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법)

  • Kim, Dae-Nyeon;Kim, Deok-Hyun;Choi, Jeong-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.