• Title/Summary/Keyword: Automatic Setting

Search Result 185, Processing Time 0.027 seconds

Development of a New Automatic Image Quality Optimization System for Mobile TFT-LCD Applications (모바일 TFT-LCD 응용을 위한 새로운 형태의 자동화질 최적화 시스템 개발)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.47 no.1
    • /
    • pp.17-28
    • /
    • 2010
  • This paper presents a new automatic TFT-LCD image quality optimization system using DSP for the first time. Since conventional manual method depends on experiences of LCD module developers, it is highly labor-intensive and requires several correction steps providing large gamma correction error. The proposed system optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. It contains module-under-test (MUT, TFT-LCD module), PC installed with program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. We have developed a new algorithm using 6-point programmable matching technique with reference gamma curve and applying automatic power setting sequence. Developed algorithm and program are generally applicable for most of the TFT-LCD modules. It is realized to calibrate gamma values of 1.8, 2.0, 2.2 and 3.0, and reduce flicker level. The control board is designed with DSP and FPGA, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than conventional manual method. We believe that the proposed system is very useful to provide high-quality TFT-LCD and to improve developing process using optimized gamma-curve setting and automatic power setting.

Automatic setting of delay time of an occupancy sensor using an adder circuit (인체감지 센서의 시간지연 설정)

  • 정영훈;송상빈;여인선
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.162-165
    • /
    • 1998
  • A certain degree of energy saving can be possible by controlling the delay time of occupancy sensor. In this paper a control circuit is designed for automatic control of delay time setting appropriate to different situations using a digital counter, two latches and an adder. The delay time is controlled by adjusting the time constant of RC circuit through on-off control of switching devices according to adder output, which determines the base current level of switching devices. And from PSpice simulation it is verified to function properly.

  • PDF

A New Image Quality Optimization System for Mobile TFT-LCD (모바일 TFT-LCD를 위한 새로운 화질 최적화 시스템)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2008.05a
    • /
    • pp.734-737
    • /
    • 2008
  • This paper presents a new automatic TFT-LCD image quality optimization system. We also have developed new algorithms using 6-point programmable matching technique with reference gamma curve, and automatic power setting sequence. It optimizes automatically gamma adjustment and power setting registers in mobile TFT-LCD driver IC to reduce gamma correction error, adjusting time, and flicker. Developed algorithms and programs are generally applicable for most of the TFT-LCD modules. The proposed optimization system contains module-under-test (MUT, TFT-LCD module), control program, multimedia display tester for measuring luminance and flicker, and control board for interface between PC and TFT-LCD module. The control board is designed with DSP, and it supports various interfaces such as RGB and CPU. Developed automatic image quality optimization system showed significantly reduced gamma adjusting time, reduced flicker, and much less average gamma error than competing system. We believe that the proposed system is very useful to provide high image quality TFT-LCD and to reduce developing process time using optimized gamma-curve setting and automatic power setting.

  • PDF

A Novel Procedure for Protection Setting in an HVDC System Based on Fault Quantities

  • Gao, Benfeng;Zhang, Ruixue;Zhang, Xuewei
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.513-521
    • /
    • 2017
  • HVDC protection setting is difficult to be calculated analytically because of its strong nonlinearity. The currently used setting method is based on the empirical setting of previous projects and then verified by digital simulation. It entails a huge workload and low efficiency. To facilitate protection setting, this paper systematically summarizes the HVDC protection characteristics and then presents a classification of HVDC protections according to the protection principles. On the basis of the fault quantities, a novel setting procedure suitable for travelling wave protection, derivative and level protection, and differential protection is proposed. The proposed procedure is illustrated and verified in detail with the example of travelling wave protection. An HVDC protection setting system that has the functions of automatic protection setting and data management is developed utilizing the C# programming language.

The Novel Control Circuit Design and Implementation for an AIS Power Amplifier Module (AIS용 전력 증폭기 모듈의 새로운 출력 제어 회로 설계 및 제작)

  • 한재룡;이종환;염경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.3
    • /
    • pp.251-257
    • /
    • 2004
  • AIS(Automatic Identification System), was suggested for the navigational data communication between ships and between ships and shore stations for the better safety of navigation, and it requires two different the transmitting output power level depending on its operating mode. According to ITU's recommendation, these levels should reach within 20 % of its final value in 1 ms. In this paper, an adequate feedback control circuit for power amplifier module is designed and implemented.

A Study on the Frequency Bias Setting of the AGC based on Frequency Response in Korea (전력계통 주파수응답 실적 기반의 국내 AGC 주파수 바이어스 설정치 산정에 관한 연구)

  • Kang, Bo-Ram;Kwon, Han-Na;Kook, Kyung-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.7
    • /
    • pp.978-983
    • /
    • 2015
  • This paper presents Frequency Bias setting for the adequate AGC(Automatic Generator Control) operation based on the frequency response of power system in Korea. AGC frequency control recovers the frequency up to 60Hz following a primary control when the frequency suddenly drops due to a fault in power system. AGC can compensate an appropriate amount of generation by calculating ACE(Are Control Error) from the frequency deviation with the AGC frequency bias set from the actual frequency response in power systems. An appropriateness of the proposed AGC bias setting is verified through case studies employing the simulation model.

An Integrated Setting-Coordination Program for Protective Relay of Transmission Systems (송전계통 보호계전기 정정협조 종합프로그램)

  • Kim, Young-Il;Lee, Seung-Jae;Choi, Myeon-Song;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.229-231
    • /
    • 1998
  • One of the most important requirements for the development of computerized relay setting system is its openness to accommodate the various changes like new panel additions. This paper describes the relay setting system(PROSET2000), which has an open system architecture and adopts the object oriented programming paradigm. Its main features include the intelligent fault type identification, automatic running of the short circuit analysis, run-time rulebase modification, automatic documentation, etc.

  • PDF

ACCURACY OF TRI AUTO ZX® IN LOCATING APICAL FORAMEN WITH ROTARY FILE (전동 file을 장착한 Tri Auto ZX®의 치근단공 인지 정확도 평가)

  • Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.578-584
    • /
    • 1999
  • The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${\pm}$0.30mm, 0.73${\pm}$0.39mm, and 0.26${\pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${\pm}$0.13mm with saline, 0.75${\pm}$0.61mm with NaOCl, and 0.25${\pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.

  • PDF

A Study on the Etching of SUS MASK using Automatic Liquid Management System (자동액관리 시스템을 이용한 SUS MASK 에칭에 관한 연구)

  • Lee, Woo-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.323-327
    • /
    • 2021
  • This paper produced SUS MASK, which is used for OLEDs, using an automatic liquid management system. The SUS MASK was tested by setting the hole diameter to 0.4 mm. The additive F300 was found to be excellent as the hole diameter was close to 0.4 mm and the error range was measured to be 0.08 on average. And as a result of measuring the weight reduction amount of CuCl2 and FeCl3 according to the change in oxidation-reduction potential (ORP), FeCl3 is relatively sensitive to ORP changes. Experiments were conducted on whether ORP (610 mV) and specific gravity (1.463) were automatically controlled while continuously etching the SUS Mask. Experimental results show that the automatic liquid management system is well controlled because the setting value is not significantly changed. After setting the hole diameter to 0.4 mm as the target, the experiment results were measured from 0.36 to 0.44. Therefore, it is expected that etching processing in the manufacturing process of SUS MASK can be improved with higher precision by applying the manufactured automatic liquid management system.