• Title/Summary/Keyword: Automatic Exposure Control

Search Result 97, Processing Time 0.032 seconds

Analysis of Image Quality According to BMI of Digital Chest Radiography: Focusing on Bureau of Radiological Health Evaluation (디지털 흉부 방사선 영상의 체질량지수에 따른 영상품질 분석: 미국 방사선 안전국 규정 평가표 중심으로)

  • Jin, Seong-jin;Im, In-Chul;Cho, Ji-Hwan
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2017
  • Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was $30.17{\pm}4.73$ and the average waist circumference was $66.91{\pm}4.67cm$. The mean Body Mass Index value was $20.21{\pm}2.23$, the mean value of mAs was $3.04{\pm}0.78$, and the mean value of Bureau of Radiological Health was $79.83{\pm}8.45$. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

Automatic Control of Fraction of Inspired Oxygen in Neonatal Oxygen Therapy using Fuzzy Logic Control

  • Chanyagorn, Pornchai;Kiratiwudhikul, Phattaradanai
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.5 no.2
    • /
    • pp.107-116
    • /
    • 2016
  • Premature babies of less than 37 weeks gestation might require oxygen therapy as an integral part of treatment and respiratory support. Because of their under-developed lungs, these so-called "preemies" might contract respiratory distress syndrome (RDS). To treat RDS, neonatal oxygen therapy is administered, where controlled oxygen gas is measured as a fraction of inspired oxygen ($FiO_2$). However, exposure to high oxygen content during long treatment could cause oxygen intoxication, which might cause permanent blindness due to retinopathy of prematurity (ROP), whereas insufficient oxygen exposure could cause severe hypoxia. A doctor would use oxygen saturation ($SpO_2$) data and prescribe a dose of $FiO_2$ to maintain $SpO_2$ within a suitable range. One objective is to maintain $SpO_2$ within the acceptable range using $FiO_2$ that is as low as possible. Adjustment of $FiO_2$ would normally be done by nurses every 15 to 30 minutes, which might not be safe in many situations. An error in $FiO_2$ adjustment during a manual procedure could be as large as +/- 2.5%. This paper presents a system that can determine an $FiO_2$ value suitable to the current $SpO_2$ and that automatically adjusts $FiO_2$ with an error clearance of +/- 0.25%.

Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant (원자력 발전소 STUD BOLT의 자동초음파 주사장치 개발)

  • Suh, D.M.;Park, M.H.;Hong, S.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.9 no.1
    • /
    • pp.106-110
    • /
    • 1989
  • Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking.(3) Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture.(3) Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced.

  • PDF

A study on development of a vision system for the test of steam generator holes in nuclear power plants (원전 증기 발생기 세관 검사용 비젼시스템 개발에 관한 연구)

  • 왕한홍;김종수;한성현;심상한
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.101-104
    • /
    • 1996
  • In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from the radiation exposure. In this paper, it is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. Digital signal processors are used in implementing real time recognition and examination of steam generator holes in the proposed vision system. Performance of proposed digital vision system is illustrated by experiment for similar steam generator model.

  • PDF

DISCRETE TIME DYNAMIC MODEL FOR TELESCOPE AUTO-GUIDING SYSTEM (망원경의 자동추적장치를 위한 이산시간 동적모델 분석)

  • Lee, Joon-Hwa
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.431-450
    • /
    • 2007
  • In the auto-guiding system for obtaining a long exposure astrophotography, CCD camera is usually used for measuring guide errors which are affected by optical dispersion and mechanical disturbances. In this paper, a discrete time dynamic model and a performance index are proposed for analysing the auto-guiding system. The optimal gain for proportional control is derived considering the optical dispersion and the disturbances. Some experiments are provided to illustrate that the optimal control gain is lower as the optical dispersion is higher.

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

Evaluation for the Usefulness of Copper Filters according to Mode Change in Digital Radiography System (DR 시스템에서 모드 변화에 따른 구리필터의 유용성 평가)

  • Kim, Jae-Kyeom;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.44 no.1
    • /
    • pp.39-46
    • /
    • 2021
  • This study confirmed the usefulness of the copper filter according to the mode change by comparing and analyzing the energy change according to the application of the copper filter and the change in effective dose and image quality according to the distance to the subject in the DR(Digital Radiography) system. The average energy increased when the copper filter was applied and the reduction rate by 50% of mAs was increased as the thickness of the copper filter increased according to the application of the 10 kVp rule in AEC mode. The effective dose decreased as the thickness increased when the copper filter was applied in AEC(Automatic Exposure Control) mode and manual mode according to the application of the 10 kVp rule, and the decrease rate decreased with increasing 10 kVp increments. As a result of analyzing the dicom images for AEC mode and manual mode with Image J. the PSNR(Peak Signal to Noise Ratio) values were approximate values of less than 30 dB for each mode and for each copper filter thickness. When the copper filter was applied, the average energy increased, so when the 10 kVp rule was applied, the mAs for each mode could be reduced, and the effective dose could also be reduced. However, as the distance and tube voltage increased, the reduction rate of mAs decreased, and the quality of the image was found to decrease when the copper filter was applied, but there was no difference in quality of the image when the copper filter thickness increased.

The Dose and Risk Reduction from Adoption of Automatic mA Control in 4D CT Scans (자동전류조절기능을 사용한 4D CT 촬영시 선량 및 위험도 저감 효과)

  • Ko, Young Eun;Je, Hyoung Uk;Hwang, Yeon;Park, Sung Ho
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.267-272
    • /
    • 2015
  • In this study, the reduction of dose and risk was evaluated from using automatic mA control in 4D CT scan of patients whose organ movement was considered for gated radiotherapy. The organ doses, CTDI, effective doses from 4D CT with and without using automatic mA control were evaluated using CT-Expo program for each 10 patients of liver and lung cancer, and the risk of exposure induced death and loss of life expectancy were evaluated using PCXMC program. It was founded that there were 26.8%, and 15.5% dose reduction in organ doses and CTDI for liver and lung cancer patients and 16.5% and 19.8% risk reduction in liver and lung cancer patients. The organ doses and effective doses were evaluated for the parameter of each patient used in CT scans, and risks considering age and gender could be evaluated. It was founded that there were 21.2% dose reduction and 18.2% risk reduction in 4D CT scan using AEC for liver and lung cancer patients.

Quantitative Evaluation of Image Quality using Automatic Exposure Control (AEC 사용 유무에 따른 영상의 화질평가)

  • Kim, Gwang-ho;Yoo, Gwan-ju;Kang, Ji-won;Ko, Bong-joo;Kim, Kyoun-lan;Kim, Min-hee;Yoon, Young-woo;Ye, Soo-young;Choi, Seok-yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.86-89
    • /
    • 2015
  • Quantitative Evaluation of Image Quality using Automatic Exposure Control This it leads, the relationship of control and image between of photographing condition, DR proper use method proposing. Chest phantom acquires Chest PA images which it follows in conditional change, Image evaluation factor (SNR (Signal to Noise Ratio), CNR (Contrast to Noise Ratio), PSNR (Peak Signal to Ratio), RMS (Root Mean Square)). It excepted RMS price, SNR, CNR, PSNR the case which uses AEC it came out being high The fact that the quality of image is better there was a case which does not use AEC. but Price it was slight. Image qualitative it was deficient in AEC use presence. Through this, the overall situation and most efficient use of radiation workers is better suited. But Passive AEC use would be appropriate for use rather than proactive AEC.

  • PDF

Reducing of Craniofacial Radiation Dose Using Automatic Exposure Control Technique in the 64 Multi-Detector Computed Tomography (64 다중 검출기 전산화단층촬영에서 관전류 자동노출조절 기법을 이용한 두개부 방사선량 감소 정도 평가)

  • Seoung, Youl-Hun;Kim, Yong-Ok;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.137-144
    • /
    • 2010
  • The purpose of this study was to evaluate the usefulness of reducing of craniofacial radiation dose using automatic exposure control (AEC) technique in the 64 multi-detector computed tomography (MDCT). We used SOMATOM Definition 64 multi-detector CT, and head of whole body phantom (KUPBU-50, Kyoto Kagaku CO. Ltd). The protocol were helical scan method with 120 kVp, 1 sec of rotation time, 5 mm of slice thickness and increment, 250 mm of FOV, $512{\times}512$ of matrix size, $64{\times}0.625\;mm$ of collimation, and 1 of pitch. The evaluation of dose reducing effect was compared the fixed tube current of 350 with AEC technique. The image quality was measured the noise using standard deviation of CT number. The range of craniofacial bone was to mentum end from calvaria apex, which devided three regions: calvaria~superciliary ridge (1 segment), superciliary ridge~acanthion (2 segment), and acanthion~mentum (3 segment). In the fixed tube current technique, CTDIvol was 57.7 mGy, DLP was $640.2\;mGy{\cdot}cm$ in the all regions. The AEC technique was showed that 1 segment were 30.7 mGy of CTDIvol, 340.7 $mGy{\cdot}cm$ of DLP, 2 segment were 46.5 mGy of CTDIvol, $515.0\;mGy{\cdot}cm$ of DLP, and 3 segment were 30.3 mGy of CTDIvol, $337.0\;mGy{\cdot}cm$ of DLP. The standard deviation of CT number was 2.622 with the fixed tube current technique and 3.023 with the AEC technique in the 1 segment, was 3.118 with the fixed tube current technique and 3.379 with the AEC technique in the 2 segment, was 2.670 with the fixed tube current technique and 3.186 with the AEC technique in the 3 segment. The craniofacial radiation dose using AEC Technique in the 64 MDCT was evaluated the usefulness of reducing for the eye, the parotid and thyroid with high radiation sensitivity particularly.