• 제목/요약/키워드: Automated Monitoring

검색결과 367건 처리시간 0.045초

디스크타입 고상추출장치 및 컬럼커플링을 이용한 물시료의 PCDD/Fs 간이분석법 (Fast Analytical Method of PCDD/Fs in Water by Combination of Disk Type Solid Phase Extraction and Column Coupling Chromatography)

  • 최재원;문부식;김경심;김정희;김순흥;백경희
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.879-886
    • /
    • 2006
  • The analytical methods of polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans (PCDD/Fs) for water sample with extremely low concentration was developed to extract large volume and to improve fast chromatography for clean up. Semi-automated solid phase extraction (SPE) system and column coupling chromatography using elution pump was optimized and applied to each processes of treatment plant. Results of disk type SPE indicated that this system was applicable below 40 L of aqueous sample with a flow rate of 0.08 ~ 0.2 L/min. Average recoveries of SPE using labeled sampling spike of $^{37}Cl$-2,3,7,8-TCDD was 97%. Column coupling method resulted in reduced clean up time, solvent volume, increased average recoveries with constant elution rate. The combined methods were applied to the monitoring of drinking water treatment plant. Limits of detection (LOD) of each process were calculated. For example, LOD of raw and treated water ranged 0.094~0.968 pg/L and 0.028~0.364 pg/L, respectively. Combined methods of extraction and cleanup techniques provided fast analysis of PCDD/Fs with high accuracy and low LODs for water samples.

SPI를 활용한 GPM IMERG 자료의 적용성 평가 (Evaluation of GPM IMERG Applicability Using SPI based Satellite Precipitation)

  • 장상민;이진영;윤선권;이태화;박경원
    • 한국농공학회논문집
    • /
    • 제59권3호
    • /
    • pp.29-39
    • /
    • 2017
  • In this study, the GPM (Global Precipitation Mission) IMERG (Integrated Multi-satellitE retrievals for GPM) rainfall data was verified and evaluated using ground AWS (Automated Weather Station) and radar in order to investigate the availability of GPM IMERG rainfall data. The SPI (Standardized Precipitation Index) was calculated based on the GPM IMERG data and also compared with the results obtained from the ground observation data for the Hoengseong Dam and Yongdam Dam areas. For the radar data, 1.5 km CAPPI rainfall data with a resolution of 10 km and 30 minutes was generated by applying the Z-R relationship ($Z=200R^{1.6}$) and used for accuracy verification. In order to calculate the SPI, PERSIANN_CDR and TRMM 3B42 were used for the period prior to the GPM IMERG data availability range. As a result of latency verification, it was confirmed that the performance is relatively higher than that of the early run mode in the late run mode. The GPM IMERG rainfall data has a high accuracy for 20 mm/h or more rainfall as a result of the comparison with the ground rainfall data. The analysis of the time scale of the SPI based on GPM IMERG and changes in normal annual precipitation adequately showed the effect of short term rainfall cases on local drought relief. In addition, the correlation coefficient and the determination coefficient were 0.83, 0.914, 0.689 and 0.835, respectively, between the SPI based GPM IMERG and the ground observation data. Therefore, it can be used as a predictive factor through the time series prediction model. We confirmed the hydrological utilization and the possibility of real time drought monitoring using SPI based on GPM IMERG rainfall, even though results presented in this study were limited to some rainfall cases.

A Bio-fluidic Device for Adaptive Sample Pretreatment and Its Application to Measurements of Escherichia coli Concentrations

  • Choi Won-Jae;Park Je-Kyun
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제11권1호
    • /
    • pp.54-60
    • /
    • 2006
  • In this paper, we describe a bio-fluidic device for adaptive sample pretreatment, in order to optimize the conditions under which absorbance assays can be conducted. This device can be successfully applied to the measurement of Escherichia coli (E. coli) concentrations using adaptive dilution, with which the dilution ratio can be adjusted during the dilution. Although many attempts have been previously made to miniaturize complex biochemical analyses at the chip scale, very few sample pretreatment processes have actually been miniaturized or automated at this point. Due to the lack of currently available on-chip pretreatments, analytical instruments tend to suffer from a limited range of analysis. This occasionally hinders the direct and quantitative analysis of specific analyses obtained from real samples. In order to overcome these issues, we exploit two novel strategies: dilution with a programmable ratio, and to-and-fro mixing. The bio-fluidic device consists of a rectangular chamber constructed of poly(dimethylsiloxane) (PDMS). This chamber has four openings, an inlet, an outlet, an air control, and an air vent. Each of the dilution cycles is comprised of four steps: detection, liquid drain, buffer injection, and to-and-fro mixing. When using adaptive sample pretreatment, the range in which E. coli concentrations can be measured is broadened, to an optical density (O.D.) range of $0.3{\sim}30$. This device may prove useful in the on-line monitoring of cell concentrations, in both fermenter and aqueous environments.

타액 중 페닐알킬아민유도체류의 일제분석법 확립 (Development of Simultaneous Quantification Method of Phenylalkylamines in Oral Fluid)

  • 최혜영;백승경;장문희;최화경;정희선
    • 약학회지
    • /
    • 제55권2호
    • /
    • pp.145-153
    • /
    • 2011
  • A simultaneous detection and quantification method for determining the Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), ketamine (KT), norketamine (NKT), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), in oral fluid was developed and validated according to international guidelines. The validated method was applied to actual oral fluid samples collected from drug abuse suspects. The recovery of phenylalkylamines from oral fluid collection devices was also assessed. Oral fluid specimens from 20 drug abuse suspects submitted by the police were collected using Salivette$^{TM}$, Quantisal$^{TM}$ or direct expectoration. The samples were screened using a biochip array analyzer. For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE with a mixed-mode cation exchange cartridge and derivatization with trifluoroacetic anhydride (TFAA). The results from the immunoassay were consistent with those from GC-MS. All the oral fluid samples gave positive results for MA, AM, PT and/or PM. The detection of phenylalkylamines in oral fluid can provide a better indication of recent use than urine or hair. Therefore, the oral fluid specimen was useful for demonstrating phenylalkylamines abuse in the driving under the influence of drug (DUID) as an alternative specimen for urine.

Auto-detection of Halo CME Parameters as the Initial Condition of Solar Wind Propagation

  • Choi, Kyu-Cheol;Park, Mi-Young;Kim, Jae-Hun
    • Journal of Astronomy and Space Sciences
    • /
    • 제34권4호
    • /
    • pp.315-330
    • /
    • 2017
  • Halo coronal mass ejections (CMEs) originating from solar activities give rise to geomagnetic storms when they reach the Earth. Variations in the geomagnetic field during a geomagnetic storm can damage satellites, communication systems, electrical power grids, and power systems, and induce currents. Therefore, automated techniques for detecting and analyzing halo CMEs have been eliciting increasing attention for the monitoring and prediction of the space weather environment. In this study, we developed an algorithm to sense and detect halo CMEs using large angle and spectrometric coronagraph (LASCO) C3 coronagraph images from the solar and heliospheric observatory (SOHO) satellite. In addition, we developed an image processing technique to derive the morphological and dynamical characteristics of halo CMEs, namely, the source location, width, actual CME speed, and arrival time at a 21.5 solar radius. The proposed halo CME automatic analysis model was validated using a model of the past three halo CME events. As a result, a solar event that occurred at 03:38 UT on Mar. 23, 2014 was predicted to arrive at Earth at 23:00 UT on Mar. 25, whereas the actual arrival time was at 04:30 UT on Mar. 26, which is a difference of 5 hr and 30 min. In addition, a solar event that occurred at 12:55 UT on Apr. 18, 2014 was estimated to arrive at Earth at 16:00 UT on Apr. 20, which is 4 hr ahead of the actual arrival time of 20:00 UT on the same day. However, the estimation error was reduced significantly compared to the ENLIL model. As a further study, the model will be applied to many more events for validation and testing, and after such tests are completed, on-line service will be provided at the Korean Space Weather Center to detect halo CMEs and derive the model parameters.

금융기관 개인정보 자산 분석 자동화 시스템의 설계와 구현 (Design and Implementation of Financial Security Automatic System for Privacy Information of Financial Institution)

  • 이정민;김인석
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.25-30
    • /
    • 2015
  • 금융기관 보안의 가장 큰 화두는 정보에 대한 유출이다. 시중 대형 은행을 비롯한 금융기관에서도 각종 해킹과 취약점을 통하여 빈번이 유출하려는 시도를 받고 있고, 이 정보의 중심은 금융기관이 보유하고 있는 고객의 개인정보 이다. 금융기관의 보안 담당자들이 개인정보 유출 방지를 위해 다각적으로 노력하고 있으나 실상은 어떤 개인정보가 어디에 있는지도 모르는 경우가 많음을 이번 논문을 준비하며 더욱 확실하게 알게 되었고, 어디에 있는지 알고 있다고 추정을 하여 검색하더라도 다른 곳에서의 발견이 빈번하며, 일일이 수동으로 검색하여 인적/시간적 낭비가 많아 IT컴플라이언스 대응이 어렵다. 본 논문은 개인정보의 주요 보관소인 PC 및 Server를 주기적으로 자동화된 시스템으로 점검 관리하여 개인정보 유출 방지 및 IT컴플라이언스 대응에 효율성을 극대화 하고자 함이다.

생체신호를 활용한 학습기반 영유아 스트레스 상태 식별 모델 연구 (A Machine Learning Approach for Stress Status Identification of Early Childhood by Using Bio-Signals)

  • 전유미;한태성;김관호
    • 한국전자거래학회지
    • /
    • 제22권2호
    • /
    • pp.1-18
    • /
    • 2017
  • 오늘날 감정 표현이 서툰 영유아가 처한 극도의 스트레스 상태를 자동적으로 파악하는 것은 영유아의 안전을 위협하며 지속적으로 발생하는 위험 상황의 실시간적인 인지를 위해 반드시 필요한 기술이다. 따라서 본 논문에서는 생체신호를 활용하여 영유아의 스트레스 상태를 분류하기 위한 기계학습 기반의 모델과 생체신호 수집용 스마트 밴드 및 모니터링용 모바일 어플리케이션을 제안한다. 구체적으로 본 연구에서는 영유아의 감정을 나타내는 주요한 요인이 되는 음성 및 심박 데이터의 조합을 활용하여 기존에 널리 알려진 데이터 마이닝 기법을 통해 영유아의 스트레스 상태 패턴을 학습하고 예측한다. 본 연구를 통해 생체신호를 활용하여 영유아의 스트레스 상태 식별을 자동화할 수 있는 가능성을 확인하였으며 나아가서 궁극적으로 영유아의 위험 상황 예방에 활용될 수 있을 것으로 기대된다.

A Review on the Sampling and Analytical Methods for Ammonia in Air

  • Das, Piw;Kim, K.H.;Sa, J.H.;Kim, J.C.;Lee, S.R.;Jeon, E.C.
    • 한국지구과학회지
    • /
    • 제28권5호
    • /
    • pp.572-584
    • /
    • 2007
  • The quantification of ammonia concentrations has received a lot of scientific attention. Numerous devices for the quantification of $NH_3$ in the ambient air have been developed to provide more technical possibilities for research in abating $NH_3$ emission from various source processes. For the proper quantification of $NH_3$, a number of sampling methods have been discussed by grouping them into different categories based on the principle of functioning. In general, active samplers employ pumps to draw air in, while passive samplers are exposed to air over a certain period of time to obtain integrated signature of $NH_3$. In case of the former, impingers and absorption flasks can be employed simultaneously with suitable absorbents to capture $NH_3$ passing through them. The methods of analysis include both in-situ and laboratory determination. In the laboratory, colorimetric or ion chromatographic methods are generally used for its quantification. In the field, a number of real time analyzers have been proven to be useful. These real time analyzers can be grouped according to their principle of operation. These analyzers may use the principle of spectroscopy (e.g. DOAS), photoacousticics (e.g. photoacoustic monitor) or Chemiluminescence ($NO_x$ analyzer). The automated annular denuder sampling system with on-line analyzer is also suitable for continuous monitoring of ammonia in air.

DEEP-South: Automated Scheduler and Data Pipeline

  • Yim, Hong-Suh;Kim, Myung-Jin;Roh, Dong-Goo;Park, Jintae;Moon, Hong-Kyu;Choi, Young-Jun;Bae, Young-Ho;Lee, Hee-Jae;Oh, Young-Seok
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.54.3-55
    • /
    • 2016
  • DEEP-South Scheduling and Data reduction System (DS SDS) consists of two separate software subsystems: Headquarters (HQ) at Korea Astronomy and Space Science Institute (KASI), and SDS Data Reduction (DR) at Korea Institute of Science and Technology Information (KISTI). HQ runs the DS Scheduling System (DSS), DS database (DB), and Control and Monitoring (C&M) designed to monitor and manage overall SDS actions. DR hosts the Moving Object Detection Program (MODP), Asteroid Spin Analysis Package (ASAP) and Data Reduction Control & Monitor (DRCM). MODP and ASAP conduct data analysis while DRCM checks if they are working properly. The functions of SDS is three-fold: (1) DSS plans schedules for three KMTNet stations, (2) DR performs data analysis, and (3) C&M checks whether DSS and DR function properly. DSS prepares a list of targets, aids users in deciding observation priority, calculates exposure time, schedules nightly runs, and archives data using Database Management System (DBMS). MODP is designed to discover moving objects on CCD images, while ASAP performs photometry and reconstructs their lightcurves. Based on ASAP lightcurve analysis and/or MODP astrometry, DSS schedules follow-up runs to be conducted with a part of, or three KMTNet telescopes.

  • PDF

DEEP-South: Round-the-Clock Physical Characterization and Survey of Small Solar System Bodies in the Southern Sky

  • Moon, Hong-Kyu;Kim, Myung-Jin;Roh, Dong-Goo;Park, Jintae;Yim, Hong-Suh;Choi, Young-Jun;Bae, Young-Ho;Lee, Hee-Jae;Oh, Young-Seok
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.54.2-54.2
    • /
    • 2016
  • Korea Microlensing Telescope Network (KMTNet) is the first optical survey system of its kind in a way that three KMTNet observatories are longitudinally well-separated, and thus have the benefit of 24-hour continuous monitoring of the southern sky. The wide-field and round-the-clock operation capabilities of this network facility are ideal for survey and the physical characterization of small Solar System bodies. We obtain their orbits, absolute magnitudes (H), three dimensional shape models, spin periods and spin states, activity levels based on the time-series broadband photometry. Their approximate surface mineralogy is also identified using colors and band slopes. The automated observation scheduler, the data pipeline, the dedicated computing facility, related research activity and the team members are collectively called 'DEEP-South' (DEep Ecliptic Patrol of Southern sky). DEEP-South observation is being made during the off-season for exoplanet search, yet part of the telescope time is shared in the period between when the Galactic bulge rises early in the morning and sets early in the evening. We present here the observation mode, strategy, software, test runs, early results, and the future plan of DEEP-South.

  • PDF