• Title/Summary/Keyword: Auto-control

Search Result 1,186, Processing Time 0.044 seconds

Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image (디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가)

  • Lee, Jin-Soo;Ko, Seong-Jin;Kang, Se-Sik;Kim, Jung-Hoon;Kim, Dong-Hyun;Kim, Changsoo
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.8
    • /
    • pp.275-283
    • /
    • 2013
  • The patient radiation dose is different depending on selection of Ion chamber when taking Chest PA which using AEC. In this paper, we studied acquiring the best diagnostic images according to selection of Ion chamber on AEC mode as well as minimizing patient radiation dose. Experimental methods were selection of Ion chamber and change of sensitivity under the same conditions as Chest PA projection. At AEC mode, two upper ion chambers sensors and one lower ion chamber sensor were divided into 7 cases according to selection of on/off. after measuring five times respectively, we obtained average value and calculated exposure dose. Image assessment was done with measured Modulation Transfer Function, Peak Signal to Noise Ratio, Root Mean Square, Signal to Noise Ratio, Contrast to Noise Ratio, Mean to Standard deviation Ratio respectively. In exposure assessment results, selection of two upper chambers was the lowest. In resolution assessment results, image of two upper chambers had the second high spatial frequency at sensitivity at 625(High) was 1.343 lp/mm. RMS value of image selecting two upper chambers was low secondly. SNR, CNR, MSR were the high value secondly. As the sensitivity was increased, radiation dose was decreased but better image could be obtained on image quality. In order to obtain the best medical images while minimizing the dose, usage of two upper ion chambers is considered to be clinically useful at sensitivity 625(High).

Distributed Construction of the Multiple-Ring Topology of the Connected Dominating Set for the Mobile Ad Hoc Networks: Boltzmann Machine Approach (무선 애드혹 망을 위한 연결 지배 집합 다중-링 위상의 분산적 구성-볼츠만 기계적 접근)

  • Park, Jae-Hyun
    • Journal of KIISE:Information Networking
    • /
    • v.34 no.3
    • /
    • pp.226-238
    • /
    • 2007
  • In this paper, we present a novel fully distributed topology control protocol that can construct the multiple-ring topology of Minimal Connected Dominating Set (MCDS) as the transport backbone for mobile ad hoc networks. It makes a topology from the minimal nodes that are chosen from all the nodes, and the constructed topology is comprised of the minimal physical links while preserving connectivity. This topology reduces the interference. The all nodes work as the nodes of the distributed parallel Boltzmann machine, of which the objective function is consisted of two Boltzmann factors: the link degree and the connection domination degree. To define these Boltzmann factors, we extend the Connected Dominating Set into a fuzzy set, and also define the fuzzy set of nodes by which the multiple-ring topology can be constructed. To construct the transport backbone of the mobile ad hoc network, the proposed protocol chooses the nodes that are the strong members of these two fuzzy sets as the clusterheads. We also ran simulations to provide the quantitative comparison against the related works in terms of the packet loss rate and the energy consumption rate. As a result, we show that the network that is constructed by the proposed protocol has far better than the other ones with respect to the packet loss rate and the energy consumption rate.

Complement-dependent Cytotoxic Crossmatch for Prevention of Hyperacute Rejection in Canine Renal Allografts (개의 신장 동종 이식에서 초급성 거부반응의 예방을 위한 보체의존성 세포독성 DLA 플래스 I 교차 반응)

  • Ghil Heh Myung;Woo Heung-Myung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.322-327
    • /
    • 2005
  • DLA class I complement-dependent cytotoxicity (CDC) cross-match method was established to control hyperacute rejections in organ transplantation. The aim of the present study is to investigate if DLA class 1 CDC corssmatch method is effective to prevent hyperacute rejections in canine renal allografts. Seven mongrel dogs of similar age and weight were used. Erythrocyte crossmatch was first performed and only the negatives were used. Among the same blood types, CDC cross-match was performed. Anti-dog serum, Hank's balanced salt solution(HBSS), and tile self-serum was used as a positive-, a negative-, and all auto-control respectively. After the reaction with class I complement, it was stained with eosin and scored by international cytotoxicity scoring system under inverted phase microscope. According to these results, kidneys oi CDC negatives among same blood types were cross-transplanted to observe the incidence of hyperacute rejections. One of four 1.2 B blood type dogs had autoantibodies. here were negative CDC results among each blood type, and also there were negative results between different blood types. Two pairs with the same blood types and negative CDC results underwent allo-transplantation each other. There were no hyperacute rejections. DLA cross-match method studied in this experiment for canine renal allograft can be effective to prevent hyperacute rejections. it may be applicable for the future studies of histocompatibility testing in canine renal allografts.

Water temperature assessment on the small ecological stream under climate change (기후변화에 따른 소하천에서의 수온 모의연구)

  • Park, Jung Sool;Kim, Sam Eun;Kwak, Jaewon;Kim, Jungwook;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.313-323
    • /
    • 2016
  • Water temperature affects physical and biological processes in ecologies on river system and is important conditions for growth rate and spawning of fish species. The objective of this study is to compare models for water temperature during the summer season for the Fourchue River (St-Alexandre-de-Kamouraska, Quebec, Canada). For this, three different models, which are CEQUEAU, Auto-regressive Moving Average with eXogenous input and Nonlinear Autoregressive with eXogenous input, were applied and compared. Also, future water temperature in the Fourchue river were simulated and analyzed its result based on the CMIP5 climate models, RCP 2.6, 4.5, 8.5 climate change scenarios. As the result of the study, the water temperature in the Fourchue river are actually changed and median water temperature will increase $0.2{\sim}0.7^{\circ}C$ in June and could decrease by $0.2{\sim}1.1^{\circ}C$ in September. Also, the UILT ($24.9^{\circ}C$) for brook trout are also likely to occurred for several days.

Process Fault Probability Generation via ARIMA Time Series Modeling of Etch Tool Data

  • Arshad, Muhammad Zeeshan;Nawaz, Javeria;Park, Jin-Su;Shin, Sung-Won;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.241-241
    • /
    • 2012
  • Semiconductor industry has been taking the advantage of improvements in process technology in order to maintain reduced device geometries and stringent performance specifications. This results in semiconductor manufacturing processes became hundreds in sequence, it is continuously expected to be increased. This may in turn reduce the yield. With a large amount of investment at stake, this motivates tighter process control and fault diagnosis. The continuous improvement in semiconductor industry demands advancements in process control and monitoring to the same degree. Any fault in the process must be detected and classified with a high degree of precision, and it is desired to be diagnosed if possible. The detected abnormality in the system is then classified to locate the source of the variation. The performance of a fault detection system is directly reflected in the yield. Therefore a highly capable fault detection system is always desirable. In this research, time series modeling of the data from an etch equipment has been investigated for the ultimate purpose of fault diagnosis. The tool data consisted of number of different parameters each being recorded at fixed time points. As the data had been collected for a number of runs, it was not synchronized due to variable delays and offsets in data acquisition system and networks. The data was then synchronized using a variant of Dynamic Time Warping (DTW) algorithm. The AutoRegressive Integrated Moving Average (ARIMA) model was then applied on the synchronized data. The ARIMA model combines both the Autoregressive model and the Moving Average model to relate the present value of the time series to its past values. As the new values of parameters are received from the equipment, the model uses them and the previous ones to provide predictions of one step ahead for each parameter. The statistical comparison of these predictions with the actual values, gives us the each parameter's probability of fault, at each time point and (once a run gets finished) for each run. This work will be extended by applying a suitable probability generating function and combining the probabilities of different parameters using Dempster-Shafer Theory (DST). DST provides a way to combine evidence that is available from different sources and gives a joint degree of belief in a hypothesis. This will give us a combined belief of fault in the process with a high precision.

  • PDF

3D Digital Design Optimization Process Considering Constructability of Freeform Structure (비정형 구조물의 시공성을 고려한 3차원 디지털 설계 최적화 프로세스)

  • Ryu, Han-Guk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.5
    • /
    • pp.35-43
    • /
    • 2013
  • Nowadays the widely used media in architecture include visualizations, animations and three-dimensional models. 3D digital methods using active CAM(Computer Aided Manufacturing) and CNC(Computerized Numerical Control) imaging have been developed for accurate shape and 3D measurements in freeform buildings. In contrast to a conventional building using auto CAD system and others, the proposed digital optimization method is based on a combination of 3D numerical data and parametric 3D model for design and construction. The objective of this paper is therefore to present digital optimization process for constructability of freeform building. The method can be useful in the effective implementation of an error-proofing process of freeform building during design and construction phase. 3D digital coordinate data can be used effectively to identify correct size of structural and finish members and installation location of each members in construction field. In addition, architects, engineers and contractors can evaluate design, materials, constructability and identify error-proofing opportunities. Other project participants can also include representatives from all levels of management, departments as well as workers and key subcontractors' personnel, if necessary. The 3D digital optimization process is therefore appropriate to serious variations in freeform shape. For future study, the developed digital optimization method is necessary to be carried out to verify the robustness and accuracy for constructability in construction field.

A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship (기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구)

  • Ryu, Younghyun;Kim, Hongryeol;Cho, Gyubaek;Kim, Hongsuk;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.412-417
    • /
    • 2015
  • The IMO MEPC has been increasingly strengthening the emission standard for marine environment protection. In particular, nitrogen oxide (NOx) emissions of all ocean-going ships built from 2016 will be required to comply with the Tier-III regulation. In this study, a vanadia based SCR (Selective Catalytic Reduction) system developed for ship application was installed on a diesel engine for power generation of the training ship T/S SAENURI in Mokpo National Maritime University. For the present study, the exhaust pipeline of the generator diesel engine was modified to fit the urea SCR system. This study investigated the NOx reduction performance according to the two kind of injection method of urea solution (40%): Auto mode through the PLC (Programable Logic Control) and Manual mode. We were able to find the ammonia slip conditions when in manual mode method. So, the optimal urea injection quantity can be controlled at each engine load (25, 35, 50%) condition. It was achieved 80% reduction on nitrogen oxide. Furthermore, we found that the NOx reduction performance was better with the load up-down (while down to 25% from 50%) than the load down-up (while up to 50% from 25%) test.

A study on the reliability and availability improvement of wireless communication in the LTE-R (철도통합무선망(LTE-R) 환경에서 무선통신 안정성과 가용성 향상을 위한 방안 연구)

  • Choi, Min-Suk;Oh, Sang-Chul;Lee, Sook-Jin;Yoon, Byung-Sik;Kim, Dong-Joon;Sung, Dong-Il
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1172-1179
    • /
    • 2020
  • With the establishment of the railway integrated radio network (LTE-R) environment, radio-based train control transmission and reception and various forms of service are provided. The smooth delivery of these services requires improved performance in a highly reliable and available wireless environment. This paper measured the LTE-R radio communication environment to improve radio communication performance of railway integrated wireless network reliability and availability, analyzed the results, and established the wireless environment model. Based on the built-up model, we also proposed an improved radio-access algorithm to control trains for improved reliability, suggesting a way to improve stability for handover that occur during open-air operation, and proposed an algorithm for frequency auto-heating to improve availability. For simulation, data were collected from the Korea Rail Network Authority (Daejeon), Manjong-Gangneung KTX route, which can measure the actual data of LTE-R wireless environment, and the results of the simulation show performance improvement through algorithm.

Characterizing Multichannel Conduit Signal Properties Using a Ground Penetrating Radar: An FDTD Analysis Approach (FDTD 수치해석을 이용한 다중 관로에 대한 GPR 탐지 신호 특성 분석)

  • Ryu, Hee-Hwan;Bae, Joo-Yeol;Song, Ki-Il;Lee, Sang-Yun
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.12
    • /
    • pp.75-91
    • /
    • 2023
  • In this study, we explore the use of ground penetrating radar (GPR) for the nondestructive survey of subsurface conduits, focusing on the challenges posed by multichannel environments. A key concern is the shadow regions created by conduits, which significantly impact survey results. The shadow regions, which are influenced by conduit position and diameter, hinder signal propagation, thereby making detection within these regions challenging. Using finite-difference time-domain numerical analysis, we examined the characteristics of conduit signals, which typically manifest in hyperbolic patterns. Particularly, we investigated three conduit arrangements: horizontal, vertical, and diagonal. Automatic gain control was applied to amplify the signals, enabling the analysis of variations in shadow regions and signal characteristics for each arrangement. In the horizontal arrangement, the proximity of the two conduits resulted in the emergence of a new hyperbolic pattern between the existing conduits. In the vertical arrangement, the lower conduit could be detected using hyperbolic signals on either side, but the detection was challenging when the upper conduit diameter exceeded that of the lower conduit. In the diagonal arrangement, signal characteristics varied based on the position of shadow regions relative to the detection range of the equipment. Asymmetrical signal patterns were observed when the shadow regions fell within the detection range, whereas the signals of the two conduits were minimally impacted when the shadow regions were outside the detection range. This study provides vital insights into accurately detecting and characterizing subsurface multichannel conduits using GPR-a significant contribution to the field of subsurface exploration and management.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.