• Title/Summary/Keyword: Auto leveling system

Search Result 10, Processing Time 0.023 seconds

A Control Strategy of Auto-Leveling Equipment of Multi-Function Radar for Vehicle based on Embedded System Modeling

  • Byeol Han;Yushin Chang;Sungyong Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.9
    • /
    • pp.1-8
    • /
    • 2023
  • This paper presents the control strategy of Auto-leveling equipment (ALE) of Multi-function radar (MFR) for vehicle using Embedded System. MFR implements surveillance patrol missions such as surface-to-air missiles and fighters with constant rotation. ALE consists of 4 Auto-leveling modules (ALM) and retains the stability with maintaining level. The gradient of vehicle can be measured and controlled by embedded systems. This paper contributes for improvement the system design with the ALM 1 set modeling. The validity of the modeling is verified using MATLAB/Simulink.

Effect of Friction on the Hysteresis of the Thrust Forces Acting on Auto Leveling Devices in Vehicle Head Lamps (헤드 램프 빛의 각도 자동 조절 장치에 작용하는 추력의 히스테리시스에 대한 마찰의 영향)

  • Baek, Hong;Kim, Jae-Hoon;Nam, Jin-Sik;Park, Sang-Shin
    • Tribology and Lubricants
    • /
    • v.35 no.6
    • /
    • pp.369-375
    • /
    • 2019
  • This paper presents a new method on how to calculate the thrust forces acting on an auto-leveling device in headlamps for passenger vehicles. The leveling device is used to lower the angle of lights when a load in the trunk of the vehicle lifts it. In the process of the headlamp design, it is imperative to predict the external forces so that the designers can decide whether to proceed or not. The device is composed of three pivot joints with no reaction moment, a plate that holds the lamp, and a leveling motor that changes rotation to linear motion. In this study, force balance, moment balance, and geometric compatibility are applied to the leveling device system so that a nonlinear system of equations can be derived; the multi-dimensional Newton-Raphson algorithm is then used to solve these. A sensitivity analysis is carried out to verify which design variables affect the system the most: the mass of the lamp and the height between the pivot and leveling device affect the thrust forces the most. Then, considering the friction forces between the moving parts, the hysteresis of the forces are derived. An experimental apparatus, designed and developed in this study, is used to verify the exactness of the derived equations. The results from experiments coincide well with the calculated results. The friction hysteresis, in particular, proves this upon analysis.

Auto-Leveling of HID Headlamp Using Preview Control

  • Yang, Boojoong;Kang, Heeyong;Yang, Sungmo
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.11
    • /
    • pp.1404-1411
    • /
    • 2002
  • A newly developed high intensity discharge (HID) automotive headlamp results in a high luminous gradient at the cutoff line, and proves the superior concept in safer and more com-fortable nighttime driving. This new headlamp technology Provides drivers expanded night vision by a significantly improved light pattern. However, the HID headlamp may dazzle other traffics during traversing a rough road or encountering an unexpected bump. To resolve this problem, an automatic headlamp leveling device is necessary. A preview control is presented for the design of the leveling system. The proposed control algorithm is capable of attenuating a dynamic glare which is one of the major detractors to a driving in dark roads. Computer simulations using ADAMS are carried out to confirm the effectiveness on the control system.

Dynamic Behavior Analysis of the Auto-leveling System for Large Scale Transporter Type Platform Equipment on the Ground Slope (경사지에서 운용 가능한 대형 차량형 플랫폼 장비 자동수평조절장치의 동적 거동)

  • Ha, Taewan;Park, Jungsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.502-515
    • /
    • 2020
  • To identify the dynamic characteristics of the Auto-leveling system applied to the Tractor-Trailer type Transporter for mounting a large scale precision equipment, Dynamics Modeling & Simulation were performed using general Dynamics Analysis Program - RecurDyn(V9R2). The axial load data, transverse load data and pad trace data of leveling actuators were obtained from M&S. And they were analyzed and compared with each other by parameters, i.e. friction coefficients on the ground, landing ram speed of actuators, and direction & quantity of ground slope. It was observed that ground contact friction coefficients affected to transverse load and pad trace; the landing ram speed of actuators to both amplitude of axial & transverse load, and this phenomena was able to explain from the frequency analysis of the axial load data; the direction of ground slope to driving sequence of landing ram of actuators. But the dynamic behaviors on the two-directional slope were very different from them on the one-directional slope and more complex.

A Control Strategy of Auto-Leveling System for Vehicle Platform based on DSP (DSP를 이용한 차량용 레이다 수평안정화장치 구동 전략)

  • Byeol Han;Yushin Chang;Sungyong Lee
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2023.07a
    • /
    • pp.507-509
    • /
    • 2023
  • 본 논문에서는 DSP (Digital Signal Processing)를 이용한 차량용 레이다 수평안정화장치 구동 전략을 제안한다. 지대공 유도 미사일용 차량용 레이다는 전방향으로 일정 속도로 회전하며 감시정찰 임무를 수행한다. 수평안정화장치는 4세트의 수평구동모듈을 이용하여 차량 플랫폼의 수평을 유지하여 레이다의 안정적인 회전을 가능하게 한다. 이를 실시간으로 구현하기 위해 임베디드시스템인 DSP를 적용하여 경사도를 측정하고, 구동모듈에 구동 명령을 인가하여 수평을 유지한다. 수평구동모터는 감속기를 통하여 모터 토크를 증가시켜 수평 안정 동작을 수행한다. 본 논문에서는 수평구동모듈 1세트를 모델링하여 수평안정화장치를 축소 구현한다. 제안하는 구동 전략의 유효성은 시뮬레이션으로 입증한다.

  • PDF

Development of a Machine Control Technology and Productivity Evaluation for Excavator (굴착기 머신 콘트롤 기술 개발 및 생산성 향상 평가)

  • Lee, Min Su;Shin, Young Il;Choi, Seung Joon;Kang, Han Byul;Cho, Ki Yong
    • Journal of Drive and Control
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • An intelligent excavator can be divided into Machine Guidance (MG), semi-automatic, and unmanned by technology. The MG technology excavator is equipped with a tilt sensor on each link of the excavator and a GPS is installed on the excavator body to inform the user of the position of the excavator bucket end. Machine control (MC) technology that assists the user's work can be divided into semi-automatic and fully automatic technology. The semi-automatic MC equipment has already been commercialized by Komatsu and Caterpillar. The MC excavator is equipped with an electro-hydraulic system, sensors and controllers to control the excavator bucket end according to the user's needs. In this study, the semi-automated excavator modified based on manual excavator, is equipped with an electro-hydraulic system, a controller system, multi-sensors and a control algorithm is developed to assist in excavation work such as leveling and grading. By applying the developed technology, it was possible to confirm productivity improvement compared to manual digging and leveling work. In the future, further research to improve the accuracy of the hydraulic precision control and collaborative work with heterogeneous construction equipment such as dump truck and automated collaboration tasks technology could be developed.

Structural analysis for the development of a vertically raise type aerial work machinery (수직상승형 고소작업차의 개발을 위한 구조해석)

  • Lee, Sang-Sik;Kim, Jun-Tae;Park, Won-Yeop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.225-231
    • /
    • 2017
  • This study was carried out for the production of aerial work machinery in high place in the orchard. In the case of orchards, there are many unpaved roads and sloping grounds to solve the problem of overturning or safety problems when working in a orchard. For more stable operation, an automatic leveling system was designed. During the structural analysis, the horizontal sensor was installed in addition to the standard that we wanted. Based on the INVENTOR, the structural analysis through 3D modeling showed that the maximum tilt of the worker was 116.49Mpa on the left and 118.26Mpa on the right.

Optimal Design of an Auto-Leg System for Washing Machines (세탁기용 자동신통저감장치($Auto-Leg^{TM}$)의 최적 설계)

  • Seo, H.S.;Lee, T.H.;Jeon, S.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.996-1001
    • /
    • 2006
  • Automatic washing machines have been improved and popularized steadily since the first electric washing machine was produced in the early 1900's. Appliance industry has tried to obtain the performance of washing machine with large capacity, high energy efficiency, low vibration and low noise levels. As the installation peace of a washer becomes closer to the living space, vibration and noise problems become more important challenges. In general, a washing machine has four legs to support its body. Four legs of the washing machine should be attached on a floor. If not so, it may cause severe vibration or walking in the spin-drying process. Unfortunately, the floor of an ordinary house is bumpy in general, and the consumers will not accept bolting washing machines to a foundation; moreover, sometimes they move the location of their washing machines to utility rooms or bath rooms or kitchens and don't care for leveling the legs exactly. In this study, we devise an auto-leg system that prevents the occurrence of abnormal vibration and walking of washing machines. It is simply composed of a spring and a friction damper. Some experiments are implemented to show the dynamic characteristics of the three-dimensional auto-legged washing machine model that is located on the even or uneven ground. A spring parameter is optimized to adjust the length of the auto-leg system automatically up to 10 mm irregularity, and the friction damper is designed to decrease a resonance induced by the spring of the auto-leg system. Some numerical results show that placing the proposed auto-leg system in a washing machine makes good performance with low vibration, as well as low noise, regardless of the unevenness of the floor.

  • PDF

Development of Centralized controller with remote control and hydraulic lift (고소작업차의 원격 제어를 포함한 중앙집중식 컨트롤러 및 유압식 상승리프트 개발)

  • Lee, Sang-Sik;Kim, Jun-Tae;Park, Won-Yeop
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.3
    • /
    • pp.232-241
    • /
    • 2017
  • This study was carried out to design the stable elements of the aerial work machinery used in the orchard and farmland which had been conducted in the previous research. A hydraulic lifting lift has been developed to work safely at irregular and inclined locations using an auto leveling system and a horizontal sensor. The development of a centralized controller including remote control has been carried out in order to control the elevated work platform. Through the developed module, we carried out on-site test run to check whether the control is stable in the elevation workbench. Through the structural analysis of the elevation workbench, the maximum load and the equal load amount that the worker can safely work on the workbench are presented.

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.