• Title/Summary/Keyword: Auto Material

Search Result 319, Processing Time 0.025 seconds

Alveolar Cleft Reconstruction Using Chin Bone and Autogenous Tooth Bone Graft Material: Reports of 5 Cases

  • Jeong, Kyung-In;Lee, Junho;Kim, Kyung-Wook;Um, In-Woong;Hara, Shingo;Mitsugi, Masaharu;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • v.6 no.1
    • /
    • pp.13-21
    • /
    • 2013
  • Purpose: To report the successful results of using chin bone graft and autogenous tooth bone graft material (AutoBT) in alveolar cleft patients. Materials and Methods: Five patients with alveolar cleft defects underwent alveolar bone grafting. Three patients were treated using chin bone graft, and the other two patients underwent AutoBT graft. After implant site development using chin bone graft in the fi rst three cases, endosseous implant restorations were placed. In case #4 and 5, AutoBT graft material was placed to guide the normal eruption of partially impacted maxillary right canine and to the upper docking site after distraction osteogenesis. Result: Successful implant restorations with closure of the oronasal fistula were achieved in alveolar cleft defect reconstruction using either chin bone graft (Case #1, 2, 3) or AutoBT graft material (Case #4, 5). Case #4 showed enlarged follicle of the right maxillary canine, indicating a normal eruption guide pattern. Conclusion: Both chin bone graft and AutoBT graft showed favorable outcomes in reconstructing alveolar cleft defects. Autogenous tooth bone graft opens up the possibility of avoiding harvesting autogenous bone graft with complications and morbidities.

Analysis of Organic Components and Osteoinductivity in Autogenous Tooth Bone Graft Material

  • Kim, Young-Kyun;Lee, Junho;Kim, Kyung-Wook;Um, In-Woong;Murata, Masaru;Ito, Katsutoshi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.6
    • /
    • pp.353-359
    • /
    • 2013
  • Purpose: Extensive research is actively ongoing for development of an ideal bone substitute that meets the gold standard. Tooth was selected as a donor site for evaluation of potentials in bone substitutes based on its similar chemical compositions to alveolar bone. Previous studies have evaluated inorganic components of autogenous tooth bone graft material (AutoBT) and osteoconductivity. In continuation from the previous studies, the current study was conducted for analysis of organic components and evaluation of osteoinductivity of AutoBT. Methods: Forty-six extracted teeth were collected from actual patients (Korea Tooth Bank, R&D Institute). Extracted teeth were processed into AutoBT and implanted in dorsal subcutaneous muscular tissues of 15 athymic mice. Biopsy samples were harvested at two, five, and eight weeks. The Bradford assay, sodium dodecyl sulphate polyacrylamide gradient gel, and western blotting were performed for investigation of organic contents of AutoBT. Results: Histology analyses showed signs of new bone formation as early as two weeks. Results of the Bradford assay indicated the existence of noncollagenous proteins (NCP). 0.29% (2.89 mg/g) of proteins were extracted by weight in the root portion of AutoBT; 0.02% (0.029 mg/g) and 1.79% (17.93 mg/g) of proteins were measured by weight in crown and block-form of AutoBT, respectively. However, recombinant human bone morphogenetic protein-2 was not observed in AutoBT. Conclusion: Within the limitation of the current study, AutoBT induced new bone formation by NCP embedded in dentin.

Stochastic FE Analysis of Plate Structure (평판구조의 추계론적 유한요소해석)

  • 최창근;노혁천
    • Computational Structural Engineering
    • /
    • v.8 no.1
    • /
    • pp.127-136
    • /
    • 1995
  • In this paper the stochastic FE analysis considering the material and geometrical property of the plate structure is performed by the weighted integral method. To consider the stochasity of the material and geometrical property, the stochastic field is assumed respectively. The mean value of the stochastic field is 0 and the value of variance is assumed as 0.1. The characteristics of the assumed stochastic field is represented by auto-correlation function. This auto-correlation function is used in evaluating the response variability of the plate structure. In this study a new auto-correlation function is derived to concern the uncertainty of the plate thickness. The newly derived auto-correlation function is a function of auto-correlation function and coefficient of variation of the assumed stochastic field. The two results, obtained by proposed Weighted Integral method and Monte Carlo Simulation method, are coincided with each other and these results are almost equal to the theoretical result that is derived in this study. In the case of considering the variability of plate thickness, the obtained result is well coincide with those of Lawrence and Monte Carlo simulation.

  • PDF

A Study on the Wiring Control Method of Hand & Auto Operation of an Easy Elevator (간이 승강기 수·자동 배선제어방식에 관한 연구)

  • 위성동;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.4
    • /
    • pp.351-357
    • /
    • 2003
  • An easy learning elevator originated is opened to compare the existed teaming equipment, and it had a high studied efficiency that the sequence control circuit can open and close with the wire. The structure of equipment to be controlled from the first floor to the fifth floors is demostrated by the constructive apparatus with the lamps to express the function of the open-close of the door according to the cage moving with a mechanical actuation of the forward reverse breaker and the motor of load, and the mechanical actuation of hand-operation control components of push-button S/W and L/S and relay etc. These components let connect each other in order to control of the elevator function with the auto program and the designed sequence control circuit. Consequently the cage could go and come till 1∼5 steps with an auto program of the elevator and the sequence control circuit. The sequence control circuit is controlled by the step of forward and reverse to follow as that the sensor function of L/S1 ∼ L/S5 let posit with the control switchs of S/W1 ∼ S/W5 of PLC testing panel and switchs of S/W1 ∼ S/W5 installed on the transparent acryl plate of the frame. In here, improved apparatus is the hand-auto operation combined learning equipment to study the principle and technique of the originate sequence control circuit and the auto program of PLC.

A prospective study on the effectiveness of newly developed autogenous tooth bone graft material for sinus bone graft procedure

  • Jun, Sang-Ho;Ahn, Jin-Soo;Lee, Jae-Il;Ahn, Kyo-Jin;Yun, Pil-Young;Kim, Young-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.6
    • /
    • pp.528-538
    • /
    • 2014
  • PURPOSE. The purpose of this prospective study was to evaluate the effectiveness of newly developed autogenous tooth bone graft material (AutoBT)application for sinus bone graft procedure. MATERIALS AND METHODS. The patients with less than 5.0 mm of residual bone height in maxillary posterior area were enrolled. For the sinus bone graft procedure, Bio-Oss was grafted in control group and AutoBT powder was grafted in experimental group. Clinical and radiographic examination were done for the comparison of grafted materials in sinus cavity between groups. At 4 months after sinus bone graft procedure, biopsy specimens were analyzed by microcomputed tomography and histomorphometric examination for the evaluation of healing state of bone graft site. RESULTS. In CT evaluation, there was no difference in bone density, bone height and sinus membrane thickness between groups. In microCT analysis, there was no difference in total bone volume, new bone volume, bone mineral density of new bone between groups. There was significant difference trabecular thickness ($0.07{\mu}m$ in Bio-Oss group Vs. $0.08{\mu}m$ in AutoBT group) (P=.006). In histomorphometric analysis, there was no difference in new bone formation, residual graft material, bone marrow space between groups. There was significant difference osteoid thickness ($8.35{\mu}m$ in Bio-Oss group Vs. $13.12{\mu}m$ in AutoBT group) (P=.025). CONCLUSION. AutoBT could be considered a viable alternative to the autogenous bone or other bone graft materials in sinus bone graft procedure.

A study on the auto-charging circuit of the battery power units using trigger characteristics of semiconductor device (반도체 스위칭 소자의 트리거 특성을 이용한 배터리 자동 충전회로에 관한 연구)

  • 김영민;황종선;박성진;임종연;송승호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.519-522
    • /
    • 2001
  • Recently, the battery charging technology and reducing technology of harmonics on AC input line are rising importantly according to increasing electrical facilities that it has been replaced battery with emergency power. In this study, I proposed that an auto-charging circuit of battery has low cost with simple-construction circuit, relative, harmonics reduction with diode tap-change method, high reliability of system for using characteristics of thyristor switching. In case of this circuit, convenience and reliability of maintenance of battery power units were more improved. 1 think that it is resulted in effect of prevention to shortening of battery life from over-charging and over-discharging and decrease of harmonics obstacle on AC input line.

  • PDF

Fabrication of High Precision Pre-amplifier for EEG Signal Measurement and Development of Auto Classification System (뇌파신호 측정을 위한 고성능 전치증폭기 제작 및 자동 신호분류 시스템 개발)

  • 도영수;장긍덕;남효덕;장호경
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.409-412
    • /
    • 2000
  • A high performance EEG signal measurement system is fabricated. It consists of high precision pre-amplifier and auto identification bandwidth unit. High precision pre-amplifier is composed of signal generator, signal amplifier with a impedance converter, body driver and isolation amplifier. The pre-amplifier is designed for low noise characteristics, high CMRR, high input impedance, high IMRR and safety, Auto identification bandwidth unit is composed of AD-converter and PIC micro-controller for real time processing EEG signal. The performance of EEG signal measurement system has been shown the classified bandwidth through the clinical demonstrations.

  • PDF