• Title/Summary/Keyword: Auditory system

Search Result 369, Processing Time 0.027 seconds

Performance Enhancement of Phoneme and Emotion Recognition by Multi-task Training of Common Neural Network (공용 신경망의 다중 학습을 통한 음소와 감정 인식의 성능 향상)

  • Kim, Jaewon;Park, Hochong
    • Journal of Broadcast Engineering
    • /
    • v.25 no.5
    • /
    • pp.742-749
    • /
    • 2020
  • This paper proposes a method for recognizing both phoneme and emotion using a common neural network and a multi-task training method for the common neural network. The common neural network performs the same function for both recognition tasks, which corresponds to the structure of multi-information recognition of human using a single auditory system. The multi-task training conducts a feature modeling that is commonly applicable to multiple information and provides generalized training, which enables to improve the performance by reducing an overfitting occurred in the conventional individual training for each information. A method for increasing phoneme recognition performance is also proposed that applies weight to the phoneme in the multi-task training. When using the same feature vector and neural network, it is confirmed that the proposed common neural network with multi-task training provides higher performance than the individual one trained for each task.

Simulation of the Loudness Recruitment using Sensorineural Hearing Impairment Modeling (감음신경성 난청의 모델링을 통한 라우드니스 누가현상의 시뮬레이션)

  • Kim, D.W.;Park, Y.C.;Kim, W.K.;Doh, W.;Park, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.63-66
    • /
    • 1997
  • With the advent of high speed digital signal processing chips, new digital techniques have been introduced to the hearing instrument. This advanced hearing instrument circuitry has led to the need or and the development of new fitting approach. A number of different fitting approaches have been developed over the past few years, yet there has been little agreement on which approach is the "best" or most appropriate to use. However, when we develop not only new hearing aid, but also its fitting method, the intensive subject-based clinical tests are necessarily accompanied. In this paper, we present an objective method to evaluate and predict the performance of hearing aids without the help of such subject-based tests. In the hearing impairment simulation (HIS) algorithm, a sensorineural hearing impairment model is established from auditory test data of the impaired subject being simulated. Also, in the hearing impairment simulation system the abnormal loudness relationships created by recruitment was transposed to the normal dynamic span of hearing. The nonlinear behavior of the loudness recruitment is defined using hearing loss unctions generated from the measurements. The recruitment simulation is validated by an experiment with two impaired listeners, who compared processed speech in the normal ear with unprocessed speech in the impaired ear. To assess the performance, the HIS algorithm was implemented in real-time using a floating-point DSP.

  • PDF

Influence on Driver Behavior According to Providing Collision Avoidance Information on Highway (고속도로의 전방 장해물 충돌방지정보 제공이 운전행동에 미치는 영향)

  • Jeon, Yong-Uk;Dae, Mun-Su
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.4
    • /
    • pp.137-143
    • /
    • 2009
  • It is necessary to develop driving assistant information in order to prevent a rear-end collision with a crashed car which is at the blind curve on highway. Laboratory experiments were performed using a driving simulator to keep the traffic environment constant. This research was evaluated the effect of driver behavior according to providing collision avoidance information which was consisted of advisory, caution, and warning information by the dangerous degree of traffic situation. Driver behavior was evaluated to analyze the collision avoidance with a crashed car, and glance behavior was examined to measure the eye movements to the display on which provided the collision avoidance information. After experiment, the significance was evaluated on provided collision avoidance information. As the result of this research, the number of collision accident is reduced when the phased information was provided. In addition, it is clear that auditory information is more important than visual information in the case of providing the second information.

A study on the simplification of HRTF within high frequency region (고역 주파수 영역에서 HRTF의 간략화에 관한 연구)

  • Lee, Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this study, we investigated the effect of the simplification for high frequency region in Head-Related Transfer Function(HRTF) on the sound localization. For this purpose, HRTF was measured and analyzed. The result in the HRTF frequency characteristic of the back sound source showed that the decrease revel of high frequency was smaller than that of low frequency region, which means the possibility of simplification in the high frequency region. Simplification was performed by flattening of the high frequency amplitude characteristics with the insertion of the low-pass filter, whose cutoff frequency is given by boundary frequency. Auditory experiments were performed to evaluate the simplified HRTF. The result showed that direction perception was not influenced by the simplification of the frequency characteristics of HRTF for the error of sound localization. The rate of confusion for the front and back was not affected by the simplification of the frequency characteristics over 8kHz of HRTF. Finally, we made it clear that the sound localization was not affected by the simplification of frequency characteristics of HRTF over 8kHz.

Reaction Test Platform and Application by Auditory and Visual Stimulus for Language Learning Ability Improvement (언어 학습 능력 향상을 위한 청각 및 시각 자극에 대한 반응속도 측정 플랫폼과 응용)

  • Lee, Hye-Ran;Beak, Seung-Hyun
    • Journal of Internet Computing and Services
    • /
    • v.11 no.1
    • /
    • pp.77-84
    • /
    • 2010
  • Children, who have a language disorder, have difficulty in expressing their reaction about stimulus of sound and vision. So it is very hard to grasp that they recognize external stimulus or not. For solving these problem, we can check response time and make them to choose stimulus by giving stimulus of sound and vision to them through Audio and Visual Stimulus and Reaction Meter System. Additionally, We can help them by improving response time by repeated study based on the results and making them to recognize and choose stimulus faster without aversion about external stimulus. It would make them not to feel uncomfortable and isolated because they are unfamiliar with external stimulus.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Enhancement Characteristics of Gadolinium Contrast Agent in the Rat Inner Ear Perilymph through CSF microcirculation (뇌척수액 미세순환을 통한 래트 내이 외림프의 가돌리늄 조영제 증강 특성)

  • Kim, Min Jung;Lee, Sang-Yeol;Lee, Hui Joong;Lee, Taekwan;Chang, Yongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.193-198
    • /
    • 2022
  • Contrast enhanced magnetic resonance imaging using gadolinium-based contrast agent (GBCA) is a very useful in vivo technique to visualize the inner ear pathology including endolymphatic hydrops. Although systemic intravenous (IV) administration can visualize the perilymph space, the visualization was possible by indirect passage of contrast agent through blood-perilymph barrier. All animal experimental procedures were performed under anesthesia with 5% isoflurane. Lipopolysaccharide (LPS) was instilled into the left tympanic cavity through the tympanic membrane using a sterile 27gauge needle to induce hydrops model. Tucker-Davis Technologies system was used to measure Auditory Brainstem Responses (ABRs). For intracerebroven-tricular (ICV) administration, 25 µmol of GADOVIST (Bayer, Berlin, Germany) was used and diluted GADOVIST injection was 10 µl. MR imaging was acquired with a 9.4 Tesla MRI scanner. Transmit-receive volume coil with 40 mm inner diameter and 75 mm out diameter was used. ICV administration well demonstrated the strong enhancement along the cerebrospinal fluid (CSF) microcirculation pathway including CSF fluid in the subarachnoid space and CSF space of the inner ear structures. On the other hand, IV administration showed no contrast enhancement along the CSF microcirculation pathway and showed weak enhancement in the inner ear structures. In case of rat hydrops model, ICV administration showed that the reduced contrast enhancement in the perilymph space of the hydrops induced inner ear compared to the contrast enhancement in the perilymph space of the normal inner ear. New systemic ICV administration method provide contrast enhancement of GBCA in the inner ear through CSF microcirculation pathway.

Feasibility of Revision Cochlear Implant Surgery for Better Speech Comprehension

  • Hwang, Kyurin;Lee, Jae Yong;Oh, Hyeon Seok;Lee, Byung Don;Jung, Jinsei;Choi, Jae Young
    • Journal of Audiology & Otology
    • /
    • v.23 no.2
    • /
    • pp.112-117
    • /
    • 2019
  • Background and Objectives: The purpose of this study was to evaluate the efficacy of revision cochlear implant (CI) surgery for better speech comprehension targeting patients with low satisfaction after first CI surgery. Subjects and Methods: Eight patients who could not upgrade speech processors because of an too early CI model and who wanted to change the whole system were included. After revision CI surgery, we compared speech comprehension before and after revision CI surgery. Categoies of Auditory Performance (CAP) score, vowel and consonant confusion test, Ling 6 sounds, word and sentence identification test were done. Results: The interval between surgeries ranged from eight years to 19 years. Same manufacturer's latest product was used for revision surgery in six cases of eight cases. Full insertion of electrode was possible in most of cases (seven of eight). CAP score (p-value=0.01), vowel confusion test (p-value=0.041), one syllable word identification test (p-value=0.026), two syllable identification test (p-value=0.028), sentence identification test (p-value=0.028) had significant improvement. Consonant confusion test (p-value=0.063), Ling 6 sound test (p-value=0.066) had improvement but it is not significant. Conclusions: Although there are some limitations of our study design, we could identify the effect of revision (upgrade) CI surgery indirectly. So we concluded that if patient complain low functional gain or low satisfaction after first CI surgery, revision (device upgrade) CI surgery is meaningful even if there is no device failure.

Feasibility of Revision Cochlear Implant Surgery for Better Speech Comprehension

  • Hwang, Kyurin;Lee, Jae Yong;Oh, Hyeon Seok;Lee, Byung Don;Jung, Jinsei;Choi, Jae Young
    • Korean Journal of Audiology
    • /
    • v.23 no.2
    • /
    • pp.112-117
    • /
    • 2019
  • Background and Objectives: The purpose of this study was to evaluate the efficacy of revision cochlear implant (CI) surgery for better speech comprehension targeting patients with low satisfaction after first CI surgery. Subjects and Methods: Eight patients who could not upgrade speech processors because of an too early CI model and who wanted to change the whole system were included. After revision CI surgery, we compared speech comprehension before and after revision CI surgery. Categoies of Auditory Performance (CAP) score, vowel and consonant confusion test, Ling 6 sounds, word and sentence identification test were done. Results: The interval between surgeries ranged from eight years to 19 years. Same manufacturer's latest product was used for revision surgery in six cases of eight cases. Full insertion of electrode was possible in most of cases (seven of eight). CAP score (p-value=0.01), vowel confusion test (p-value=0.041), one syllable word identification test (p-value=0.026), two syllable identification test (p-value=0.028), sentence identification test (p-value=0.028) had significant improvement. Consonant confusion test (p-value=0.063), Ling 6 sound test (p-value=0.066) had improvement but it is not significant. Conclusions: Although there are some limitations of our study design, we could identify the effect of revision (upgrade) CI surgery indirectly. So we concluded that if patient complain low functional gain or low satisfaction after first CI surgery, revision (device upgrade) CI surgery is meaningful even if there is no device failure.