• 제목/요약/키워드: Auditory Response

검색결과 195건 처리시간 0.024초

청각 단어 재인에서 나타난 한국어 단어길이 효과 (The Korean Word Length Effect on Auditory Word Recognition)

  • 최원일;남기춘
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2002년도 11월 학술대회지
    • /
    • pp.137-140
    • /
    • 2002
  • This study was conducted to examine the korean word length effects on auditory word recognition. Linguistically, word length can be defined by several sublexical units such as letters, phonemes, syllables, and so on. In order to investigate which units are used in auditory word recognition, lexical decision task was used. Experiment 1 and 2 showed that syllable length affected response time, and syllable length interacted with word frequency. As a result, in recognizing auditory word syllable length was important variable.

  • PDF

개에서 Brain-stem Auditory Evoked Responses를 이용한 Deafness 진단 (Brain-stem Auditory Evoked Responses as a Diagnostic tool for Deafness in Dogs)

  • 윤영심;연성찬;권오경;남치주
    • 한국임상수의학회지
    • /
    • 제15권2호
    • /
    • pp.410-416
    • /
    • 1998
  • These experiments were designed to evaluate the possibility of brain-stem auditory evoked responses(BAER) as a diagnostic tool for deafness in dogs. The BAER was recorded from three different groups of dogs; the normal dogs,'dog with otitis externa and dogs with unilateral destruction of cochlear. BAER of the normal dogs was consisted of distinct five peaks(I, II, III-IV, V). Furthermore, the clear shapes of waveform were observed at 85 dB. The latency of BAER was increased with reducing the intensity of sound-stimulus. The highest threshold of BAER was measured at 2 KHz with 10-30 dB. Dog with otitis externs demonstrated unclear shapes of BAER compared to the that of normal dogs. In the dogs with unilateral destruction of cochlear, the flat and indistinct waveform of BAER was recorded from the cochlear destroyed ear while that of BAER from normal side of ears did not show any differences from the normal BAER. These results indicate that the BAER can be clinically used in order to diagnose the deafness in dogs.

  • PDF

Effects of Carrier Wave on the Brain Stem Electric Response (BER) in Scala Tympanic Electrode Array

  • Duck-Hwann Lim;Byu
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.105-112
    • /
    • 1982
  • Using electronic cochlear implant system, we studied in cats the difference in the response of the brain stem evoked response (BER) during the stimulation with the acoustic signals and the electric signals. These brain stem electric responses were analyzed using the integral pulse frequency modulation method of the auditory nervous system. Animal experimental results and the analysis show that the carrier wave hasimprored the frequency specificity. of the electronic auditory prosthesis.

  • PDF

외관(外關)(TE5).협계(俠谿)(GB43) 자침이 SQUID로 측정한 뇌 청각영역의 뇌자도(腦磁圖) 변화에 미치는 영향 (A SQUID MEG Study on the Auditory Primary Response induced by Acupuncture on TE5 (Waiguan).GB43 (Xiaxi))

  • 최찬헌;라기웅;장경선;나창수
    • Korean Journal of Acupuncture
    • /
    • 제23권4호
    • /
    • pp.135-145
    • /
    • 2006
  • Objectives and Methods : Using the 2-channel DROS SQUID (Korea Research Institute of Standards of Science, 1999), the present study was carried out to record changes elicited in the auditory cortex by acupuncture stimulus on right TE5 (Waiguan) and GB43 (Xiaxi). Needle-retention stimulation of TE5 and GB43 were done for acquiring the brain activities changed by acupuncture. Acupoint TE5 and GB43 is known to be effective for the treatment of ear-related disease, such as deafness and tinnitus, and to be suspected to be related to the auditory cortex. Auditory evoked magnetic fields were recorded hem the left hemisphere of five subjects, in response to contralateral ear stimulation by irregularly spaced 170 msec long 1kHz tone busts (Korea Research Institute of Standards of Science) Results and Conclusions : The result as follows. The latency and amplitude of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on TE5 were 4msec and 9.2 fT, respectively, which were slower and smaller than those of no-acupuncture condition. The latency and amplitude of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on GB43 were 7.2 msec and 1.6 fT, respectively, which were slower and larger than those of no-acupuncture condition. The latency of SQUID MEG responses at the human auditory cortex changed by needle-retention condition on GB43 condition was slower than that of TE5 acupuncture condition.

  • PDF

시청각 자극 및 인체 반응 계측 시스템 개발 (Development of System of the Visuo-Auditory Stimulation and Human Responses Measurement)

  • 유미;정선용;박용군;이상민;권대규;홍철운;김남균
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.535-538
    • /
    • 2005
  • The purpose of this work is to study a process organization on space cognition by visio-auditory stimulation. We develop the system of visuo-auditory stimulation and Humans responses measurement to observe the relationship between the sensory and the motor system fur the localization of visual and auditory target direction in the space. The experiments is performed in a soundproof chamber, 2163 red, green and yellow LED(Luminescent Diode, Brightness: $20cd/m^2$ 1 degree apart each other)arrayed in front of half-circle panel were used and 57 Speaker(5 degree apart each other) arrayed in the hidden of half-circle panel. Physiological parameters such as EOG (Electro-Oculography), head movement and their synergic control are measured by BIOPAC system and Optotrak Certus. This result shows that the response latency time of the perception motion in the center is laster than the periphery of panel. These results can be used in the study of characterizing the spatial cognition.

  • PDF

청각 brainstem의 해석 (Interpretaion of Auditory Brainstem Response)

  • 최동우;백승화
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.237-239
    • /
    • 1996
  • In this paper, we present the ABR(Auditory Brainstem Response) as a clinical application. ABRs are composed of several waves or peaks. In recent years, the use of ABRs has gained popularity as one of the methods of choice in determinig hearing thresholds of newborns and infants. We introduce labeling and computational methods of peak identification in ABR.

  • PDF

감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로- (A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change-)

  • 이자형;하영수
    • 대한간호학회지
    • /
    • 제13권3호
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF

A Comparative Study of Insert Earphones and Circumaural Earphones in the Brainstem Auditory-Evoked Response Test of Dogs

  • Kim, Sang-Woo;Song, Joong-Hyun;An, Su-Jin;Yu, Do-Hyeon;Kim, Young Joo;Han, Donghyun;Jung, Dong-In
    • 한국임상수의학회지
    • /
    • 제37권3호
    • /
    • pp.123-129
    • /
    • 2020
  • We aimed to investigate the differences in the efficacy of insert and circumaural earphones when performing the brainstem auditory evoked response (BAER) test with dogs. Hearing loss may occur congenitally or secondarily in dogs. The BAER test, unlike the classical ethological method, is the most reliable diagnostic tool to assess canine auditory function. Furthermore, there are certain advantages of using insert earphones rather than the standard, circumaural earphones. We subjected eight dogs to the BAER test with insert earphones and circumaural earphones. The result revealed that the latency of waves was delayed with an insert earphone. The inter-peak latency did not show any significant differences between the two transducers, and the threshold was higher when using an insert earphone. Moreover, the circumaural headphones produced a greater degree of crossover effect than the insert earphones, and this cross-over effect could affect the outcomes of the BAER test. Considering these results, we concluded that insert earphones may be more appropriate when performing the canine BAER test.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • Journal of Audiology & Otology
    • /
    • 제25권4호
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.

Influence of Stimulus Polarity on the Auditory Brainstem Response From Level-Specific Chirp

  • Dzulkarnain, Ahmad Aidil Arafat;Salamat, Sabrina;Shahrudin, Fatin Amira;Jamal, Fatin Nabilah;Zakaria, Mohd Normani
    • 대한청각학회지
    • /
    • 제25권4호
    • /
    • pp.199-208
    • /
    • 2021
  • Background and Objectives: No known studies have investigated the influence of stimulus polarity on the Auditory Brainstem Response (ABR) elicited from level-specific (LS) chirp. This study is important as it provides a better understanding of the stimulus polarity selection for ABR elicited from LS chirp stimulus. We explored the influence of stimulus polarity on the ABR from LS chirp compared to the ABR from click at 80 dBnHL in normal-hearing adults. Subjects and Methods: Nineteen adults with normal hearing participated. The ABRs were acquired using click and LS chirp stimuli using three stimulus polarities (rarefaction, condensation, and alternating) at 80 dBnHL. The ABRs were tested only on the right ear at a stimulus rate of 33.33 Hz. The ABR test was stopped when the recording reached the residual noise level of 0.04 μV. The ABRs amplitudes, absolute latencies, inter-peak latencies (IPLs), and the recorded number of averages were statistically compared among ABRs at different stimulus polarities and stimuli combinations. Results: Rarefaction polarity had the largest ABR amplitudes and SNRs compared with other stimulus polarities in both stimuli. There were marginal differences in the absolute latencies and IPLs among stimulus polarities. No significant difference in the number of averages required to reach the stopping criteria was found. Conclusions: Stimulus polarities have a significant influence on the ABR to LS chirp. Rarefaction polarity is recommended for clinical use because of its larger ABR peak I, III, and V amplitudes than those of the other stimulus polarities.