• Title/Summary/Keyword: Auditory

Search Result 1,449, Processing Time 0.025 seconds

A proposal for managing electronic document of the government (정부기관의 전자문서관리 방향)

  • Lee, Jae-Ha;Yoon, Dai-Hyun
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.1 no.1
    • /
    • pp.245-257
    • /
    • 2001
  • Recently, The government has been brought in the electronic document system. So, It's been increasing the job processing with the electronic approval and the distribution business. However because of the variety of the storage type of electronic document, it's expected many difficulties in the public-usage and etemity-preservation of the information later. also, There are several problems to manage electronic document system, for example, absence of the important function for managing records, etc. So, We propose the methodology as a way to solve several problems of managing electronic document in this paper. It grows the business which is produced in processing the electronic records management. The kind of document file produced by the government is various. Through introducing the standard format of document file, hereafter it has an effect on helpfulness in standardizing the electronic document system, and people recognize the situation of problem to append the important function of the preservation and usage for the electronic document system. The key task is to make the document system with keeping records and following functions according to the law of records management. As applying the standard electronic document system to manage records, the records of the processing section to the data center and then the records of the data center transfer to the government records and archives center. So, the records which be transferred can be preservative and available. The record, such as visual and auditory record which is not easy to digitalize, can be digitally preservative and available in the government records and archives center.

Symptoms and Cognitive Function in Chronic Schizophrenia: 6 Months Follow-up Study (만성 정신분열병 환자에서 증상과 인지기능:6개월 개월 추적연구)

  • Kim, Chul-Kwon;Kim, Seong-Hwan;Choe, Byeong-Moo
    • Sleep Medicine and Psychophysiology
    • /
    • v.11 no.1
    • /
    • pp.44-49
    • /
    • 2004
  • Objectives: The purpose of this study was to investigate whether longitudinal changes in positive and negative symptoms affect cognitive functioning in chronic schizophrenia. Methods: Sixty-eight patients diagnosed with DSM-IV schizophrenia were examined on two occasions over 6 months for symptoms and cognitive changes. Symptoms were measured by PANSS. Cognitive functions were examined for sustained attention, executive function, concentration and attention, and verbal memory and learning using Degraded Stimulus Continuous Performance Test, Wisconsin Card Sorting Test, Digit Span, and Rey Auditory Verbal Learning Test, respectively. Twenty control subjects were assessed to compare the cognitive scores of remitted schizophrenic patients. Results: Patients showed significant improvement in symptoms and all cognitive tests after 6 months treatments. Significant improvements in positive and negative symptoms did not predict improvements in any aspect of cognitive functioning measured. Normal controls performed significantly better than remitted schizophrenic patients on all cognitive tests. The results show no relationship between change in symptoms and change in cognition in chronic schizophrenia. Conclusion: We suggest that symptomatic and cognitive impairment may be a distinct construct. These findings highlight the importance of treating cognitive impairment in addition to the clinical symptoms of schizophrenia.

  • PDF

Studies on Audiological Significance of the Bing Test (Being test의 임상청각학적 의의에 대한 고찰)

  • 이희배;차창일;노관택
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.8.3-8
    • /
    • 1978
  • In normal auditory systems, the difference between the bone conduction thresholds obtained with the test ear opened and occluded in low frequency signals below 1, 000Hz is about 10~25 dB. But no difference in these thresholds suggests the presence of a lesion in the conductive mechanism. Sullivan added the differences in these thresholds at 250Hz, 500Hz and 1,000Hz and called "Occlusion Index". In oder to study the audiological significance, we have measured the occlusion index in 40 ears of normal persons, 20 ears of chronic otitis media patients and 20 ears of sensori-neural hearing impairment patients. We also measured the static compliance in 40 normal ears and observed the correlation with the occlusion index. The results are as follows: 1. Occlusion index was 33. $10\pm10.63dB$ in normal group, $3.10\pm3.03dB$ in chronic otitis media; group, $28.10\pm15.17dB$ in sensori-neural group. 2. Static compliance in normal group was $0.61\pm0.31cc$ (0.22~1.75cc) 3. Occlusion index showed inverse proportion to static compliance.

  • PDF

Development of Management Guidelines and Procedure for Anthropometric Suitability Assessment: Control Room Design Factors in Nuclear Power Plants

  • Lee, Kyung-Sun;Lee, Yong-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.1
    • /
    • pp.29-43
    • /
    • 2015
  • Objective: The aim of this study is to develop management guidelines and a procedure for an anthropometric suitability assessment of the main control room (MCR) in nuclear power plants (NPPs). Background: The condition of the MCR should be suitable for the work crews in NPPs. The suitability of the MCR depends closely on the anthropometric dimensions and ergonomic factors of the users. In particular, the MCR workspace design in NPPs is important due to the close relationship with operating crews and their work failures. Many documents and criteria have recommended that anthropometry dimensions and their studies are one of the foremost processes of the MCR design in NPPs. If these factors are not properly considered, users can feel burdened about their work and the human errors that might occur. Method: The procedure for the anthropometric suitability assessment consists of 5 phases: 1) selection of the anthropometric suitability evaluation dimensions, 2) establishment of a measurement method according to the evaluation dimensions, 3) establishment of criteria for suitability evaluation dimensions, 4) establishment of rating scale and improvement methods according to the evaluation dimensions, and 5) assessment of the final grade for evaluation dimensions. The management guidelines for an anthropometric suitability assessment were completed using 10 factors: 1) director, 2) subject, 3) evaluation period, 4) measurement method and criteria, 5) selection of equipment, 6) measurement and evaluation, 7) suitability evaluation, 8) data sharing, 9) data storage, and 10) management according to the suitability grade. Results: We propose a set of 17 anthropometric dimensions for the size, cognition/perception action/behavior, and their relationships with human errors regarding the MCR design variables through a case study. The 17 selected dimensions are height, sitting height, eye height from floor, eye height above seat, arm length, functional reach, extended functional reach, radius reach, visual field, peripheral perception, hyperopia/myopia/astigmatism, color blindness, auditory acuity, finger dexterity, hand function, body angle, and manual muscle test. We proposed criteria on these 17 anthropometric dimensions for a suitability evaluation and suggested an improvement method according to the evaluation dimensions. Conclusion: The results of this study can improve the human performance of the crew in an MCR. These management guidelines and a procedure for an anthropometric suitability assessment will be able to prevent human errors due to inadequate anthropometric dimensions. Application: The proposed set of anthropometric dimensions can be integrated into a managerial index for the anthropometric suitability of the operating crews for more careful countermeasures to human errors in NPPs.

Comparative Studies of Perceiving Korean Monosyllabic Digit Words under Different Speech Compression Schemes (음성압축 방식의 변화가 한국어 단음절 숫자 인지기능에 미치는 영향의 비교 연구)

  • Lim, Dukhwan;Won, Yookyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.3
    • /
    • pp.262-268
    • /
    • 2013
  • The performances of speech compression schemes appeared to be dependent on the response profiles to compressed stimuli and the features of individual languages to some extent. Although these response profiles were critical in comparing various compression outcomes, the related data were limited in number for Korean monosyllabic words. From the previous study, data from PNT (Preserving No Trait) compression was selected as a base set for comparison. In this study, the outcomes from PPT (Preserving Pitch Trait) and PTT (Preserving Time Trait) were analyzed under the same condition. Then, the properties of these three widely used representative compression schemes were quantitatively compared in normal hearing adults (N=20) for controlled Korean quintet digit sets (0 through 9). Results showed that PPT compression scheme exhibited the best perceptual performances for the Korean quintet digit sets in the final outcomes (PPT>PTT>PNT). The compression ratios of 50% performances were estimated as about 20%, 42%, and 44% for PPT, PTT, and PNT, respectively. The data indicated the influences of the salient psychoacoustic features of the three representative compressions on perceiving Korean monosyllabic digit words. This controlled procedure with monosyllabic quintet sets can evaluate efficiency and effectiveness of other compression schemes and may also contribute to diagnosing auditory processing disorders and fitting special hearing aids with compression issues.

A Statistical Study of Foreign Bodies in Food and Air Passages (식도 및 기도 이물의 통계적 고찰)

  • 엄재욱;윤병용
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.10.1-10
    • /
    • 1983
  • We have analysed the 76 cases of the foreign bodies of our ENT department during the period from Jun. 1973 to Feb. 1983. The following results were obtained and were reported. 1) Distribution of these whole 105 cases, 68 cases (64.8 %) were lodged in esophagus, 13 cases (12.4 %) were in the nasal cavities, 9 cases (8.5 %) were in the oral cavity and throat, 8 cases (7.6 %) were in the air passages, and 7 cases (6.7 %) were in the external auditory canal. 2) The sorts of the esophageal foreign bodies, the coins were the most cases(53 cases - 77.9 %) and other sites were shown of variable kinds. 3) Age distribution of the esophageal foreign bodies were mostly in under 5 years of age (49 cases - 72 %) and in cases of the air passages, all the 8 cases were in under 10. 4) In the localities of the esophageal foreign bodies, first narrowing was the most frequent site (61 cases - 89.7 %), and of air passages, 6 cases were in the left main bronchus, more that of Rt. main bronchus. 5) During the lodgement of esophageal foreign bodies, 58 cases (85.3 %) were visited to our ENT department within 24 hours. In the cases of air passages, most were viaited in 3 to 7 days (6 cases -75 %).

  • PDF

A Study on Real-Time Loudness Metering Algorithm for Digital Broadcasting (디지털 방송용 오디오 레벨 계측 알고리즘의 실시간화 연구)

  • Park Seong-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.4 s.95
    • /
    • pp.427-437
    • /
    • 2005
  • In this paper, the perceived audio level metering algorithm of digital audio sound to be able to operate in real-time is proposed. Through analyzing a conventional recommendation ITU-RBS1387-I for objective audio quality analysis, FFT-based loudness metering algorithm is implemented and the real-time method of that algorithm was advised and proved. The proposed method is based on look-up table. In order to prove the proved method, using 23 pure tones and 30 preselected digital audio samples, its performance and operation time is evaluated. Its performance, compared with an original algorithm's, have a good figure of less than $2\;\%$ error even if look-up table related with spectral spreading have large level resolution of $10\;\cal{dB}$. The proposed algorithm take only 1/21 of original algorithm's measuring time. Also, in the proposed algorithm auditory pitch group energy calculation take 1/450 of original algorithm's and excitation calculation take 1/3.57. In conclusion, the proposed algorithm is expected to be implemented into DSP-based real-time loudness meter.

Grand Average in MEG and Crude Estimation of Anatomical Site (뇌자도에서 전체 평균과 이를 이용한 해부학적 위치 추정)

  • Kwon H.;Kim K.;Kim J. M.;Lee Y. H.;Park Y. K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.575-580
    • /
    • 2004
  • In this work, a method is presented to find an anatomical site of a current source crudely in a standard brain using grand average of MEG data. Minimum norm estimation algorithm and truncated singular value decomposition were applied to calculate the distributed sources that can reproduce the measured signals. Grand average over all subjects was obtained from the transformed signals, which would be detected in a standard sensor plane by the obtained distributed current sources. In the simulation study, it was shown that the localized dipole using the grand average is consistent with the mean location of localized dipoles of all subjects within several mm even with large inter-individual differences of sensor positions. This result suggests that the mean location of low level signal source can be estimated as a dipole source in grand average and it was confirmed in the localization of the current source of N100m. when the localized dipole is registered on a standard brain. This result also suggests that the activity region obtained from grand average can be crudely estimated on a standard brain using the source location of the N100m as a reference point.

Relationships between Learning Styles and Science Process Skills of Students of the Gifted Class in Elementary School (초등과학영재학급 학생의 학습양식과 과학탐구능력 간의 상관관계)

  • Choi Sun-Young;Song Hyeon-Jeong;Kang Ho-Kam
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.2
    • /
    • pp.103-110
    • /
    • 2005
  • The purpose of this study was to investigate the relation between the learning styles and science process skills of students of the gifted class in elementary school. Subjects were forty-eight students of the gifted class who are in the fifth grade studying at the gifted class of S elementary school in Bucheon, M and Y elementary school in Incheon on learning styles and science process skills of students. Learning Style Profile (LSP) was used as instrument to survey learning style of students of the gifted class which was developed by NASSP, and consists of four categories (cognitive skills, perceptual response, orientation and teaming preferences) and twenty-four subscales. The results of this study were as follows: 1. In the learning styles test, students of the gifted class have higher scores of spatial skill, sequential processing skill, persistence orientation, manipulative preference, temperature preference and afternoon preference than general class students, but they have lower scores of discrimination skill and lighting preference, and there were statistically significant difference. 2. In science process skills test, there were statistically significant difference between students of the gifted class and general students. 3. In the correlation between the learning styles and science process skills, there was positive correlation of observing skill with spatial skill and manipulate skill of cognitive skill domain. For classifying skill, there was positive correlation with visual perceptual response, but was negative correlations with auditory and emotive perceptual response of perceptual response domain and with evening preference and verbal risk orientation of study preference domain. For measuring skill, there was positive correlation with sequential processing skill of cognitive skill domain. For formulating hypotheses, there was controlling variables, there was positive correlation with sequential processing skill and simultaneous processing skill of cognitive skill domain, and with verbal-spatial preference and early morning study preference of study preference domain. When planning and managing the gifted class, it will be beneficial and effective to consider the meaningful relations between the elements of loaming style and science process skills in order to improve science process skills.

  • PDF

Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid (이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰)

  • Jung, Eui-Sung;Seong, Ki-Woong;Lim, Hyung-Gyu;Lee, Jang-Woo;Kim, Dong-Wook;Lee, Jyung-Hyun;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.