765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

변압기 소음에 의한 변전소 소음예측 및 저소음 변압기 현장적용 (The Audible Noise Prediction of the Substation due to Transformer Audible Noise and the Field Application of the Low Noise Transformer)

  • 권동진;구교선;김경탁;우정욱
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1382-1387
    • /
    • 2010
  • Recently, there has been a growing interest in the environmental conservation. Accordingly, problems related to the audible noise of transformers have became more frequent. Therefore, it is urgent to find a fundamental solution about the audible noises in the substations. This paper described a sort of fundamental solution to solve the noise problem. As a fundamental solution, we suggested the proper audible noise level of transformers through noise prediction in the substation construction phase. And we applied the low noise transformers which have the predicted noise level. As the result, we are able to satisfy the noise regulation through measuring 43.6dBA at the boundary of substation. It is confirmed that the average error rate of prediction was within 3 percent.

시각장애인의 교차로 안전횡단 지원 BLE 기반 음향신호기 개발 및 현장 적용사례 (Development and Application of BLE-Based Audible Pedestrian Signal (APS) for Intersection Safety Crossing of Blind People)

  • 김형선;김주완;장인성
    • 한국IT서비스학회지
    • /
    • 제16권4호
    • /
    • pp.223-234
    • /
    • 2017
  • The audible pedestrian signal (APS) is an add-on device which connects to the pedestrian signaling device and informs the contents and changes of the signaling by sound. It provides walking direction information of the pedestrian crossing so that the blind people can safely cross the pedestrian crossing. In an intersection where a plurality of audible pedestrian signal (APS) are installed at an intersection crosswalk, existing audible pedestrian signal (APS) operate simultaneously in the communication radius of a wireless remote controller, which may cause confusion for the blind people and the public may complain about the noise. In this paper, we developed a BLE (Bluetooth Low Energy)-based audible pedestrian signal (APS) system capable of supporting two-way communications with a smart-phone that can cross the intersection safely and improve the walking comfort and traffic safety for the blind people. The proposed method is a method in which the BLE beacon communication based audible pedestrian signal (APS) presents active service to the blind people, and the existing audible pedestrian signal (APS) is a way of requesting the passive service by the blind people with the wireless remote control by the unidirectional communication based on 358Mhz. The developed system is installed in the crossroad of Doma-dong, Seo-gu, Daejeon, and it is tested and operated by the blind people. The satisfaction evaluation and analysis of the audible pedestrian signal (APS) for the blind people have good results and are planned to be expanded in the future.

Development of AC Transmassion Line Audible Noise Prediction Formulas Using Evolutionary Computations

  • Yang, Kwang-Ho;Park, June-Ho;Hwang, Gi-Hyun;Kim, Jeong-Boo
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권6호
    • /
    • pp.116-122
    • /
    • 1997
  • The audible noise produced by corona discharge in high voltage transmission lines is the most important line design consideration. In this paper, more accurate and useful formulas for predicting the A-weighted audible noise during heavy and light rain in alternative current (AC) transmission lines are proposed through comparison with the existing formulas. The proposed formulas are developed by the applications of evolutionary computations (ECs) to audible noise data base from long-term measurement.

  • PDF

154kV 전력용 변압기의 부하소음 및 냉각팬 소음 분석 (An Analysis on the Audible Sound Due to Load and Cooling Fan for 154kV Power Transformers)

  • 구교선;우정욱;곽주식;김경탁;권동진
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.298-304
    • /
    • 2010
  • Recently, the audible sound level of power transformer has been reduced due to development of new material and enhancement of manufacturing technology. There is lack of research on the audible sound of winding and cooling fan because the research on reduction of audible sound is concentrated on the core sound. Therefore this paper describes 3 kinds(core, winding and cooling fan) of transformer sound source. Also this paper analyzes the effect of load sound and cooling fan sound on the total transformer sounds. As the results, total sound level of 79dBA class transformer rises 0.2~0.3dB due to effect of load sound and rises 2.1~3.5dB due to effect of cooling fan sound. Also, total sound level of 55dBA class transformer rises 2.3~2.9dB due to effect of load sound and rises 1.9~3.5dB due to effect of cooling fan sound.

공동주택에서의 화재 경보음 전달특성에 관한 연구 (An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings)

  • 이민주;김명준;윤명오
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

모바일 TFT-LCD 모듈에서 발생하는 가청잡음을 줄이기 위한 새로운 방법 (A New Approach far Reducing Audible Noise in Mobile TFT LCD Module)

  • 류지열;노석호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 춘계종합학술대회
    • /
    • pp.540-543
    • /
    • 2007
  • 본 논문에서는 모바일 TFT-LCD 모듈에서 발생하는 가청잡음을 감소시키기 위한 새로운 방법을 제안한다. 또한 가청잡음에 영향을 미치는 중요 인자들을 분석하였다. 이러한 잡음원은 FPCB와 LCD 패널간의 진동 및 윈도우와 백라이트에 충전되어 있던 정전기와 같은 다양한 중요 인자들로부터 유래됨을 확인하였다. 윈도우에 충전되어 있던 정전기로 인한 잡음 수준을 분석하기 위해 윈도우가 없는 LCD 모듈과 윈도우가 있는 LCD 모듈이 동시에 평가되었다. 신뢰감이 있고 재현성이 있는 데이터를 확보하기 위해 테스트 지그 및 측정시스템을 구축하였다.

  • PDF

Electromagnetically Excited Audible Noise in Electrical Machines

  • Hameyer, Kay;Henrotte, Francois;Delaere, Koen
    • 소음진동
    • /
    • 제13권2호
    • /
    • pp.109-118
    • /
    • 2003
  • With the rising utilisation of electrical machines to increase the output-Power of the device several problems occur. Next to probable additional losses and other parasitic effects, aspects concerning the audible noise radiated by the device are of particular interest. This contribution is intended to give an overview to the problematic of the analysis of vibrations and audible noise radiated by electrical machines. It is not the intention of the authors to set off a scientific firework with various complicated equations in this contribution. The paper should rather give an insight in a complicated technical matter and should help to understand the mechanism of vibration and parasitic noise generation in electrical machines. Rotating machines, such as the induction motor as well as non-rotating electrical machines, such as inductors or transformers are studied. The origin of vibrations leading to noise radiations is studied and discussed to illustrate the way in which the analysis of the governing effects can be performed. Magnetically generated radial pullout force waves in rotating electrical machines are the main cause of the excited audible noise, whereas magnetostriction plays an important role in transformers.

모터 구동 장치의 가청 스위칭 소음 저감을 위한 2상 및 3상 랜덤 펄스 위치 PWM기법의 성능 비교 (A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme for Mitigation of Audible Switching Acoustic Noise in Motor Drives)

  • 정영국;위석오;나석환;임영철
    • 전력전자학회논문지
    • /
    • 제7권3호
    • /
    • pp.224-236
    • /
    • 2002
  • PWM기법의 성능을 비교하고 있다. 랜덤 펄스 위치 PWM기법은 2상 또는 3상 펄스들을 변조 구간내의 임의의 위치에 랜덤하게 배치하고 인버터 스위칭에 의하여 고조파의 스펙트럼을 광역화하는 RPWM기법이다. 시뮬레이션과 실험에 의하여 인버터 출력 전압의 고조파 스펙트럼과 맥동 전류 파형 그리고 모터의 가청 스위칭 소음의 저감 효과를 비교 검토하였다. 스위칭 손실 및 연산시간 그리고 구현의 용이성에서 3상 RPWM보다는 2상 RPWM이 양호하며, 고조파의 광대역화 측면에서는 3상 RPWM이 보다 좋은 성능을 지니고 있음을 알 수 있었다. 또한 가청 스위칭 소음저감은 2상 RPWM과 3상 RPWM이 거의 유사한 성능을 갖고 있음이 확인되었다.

Flexible audible display(VizDio$^{TM}$) using polymer dispersed liquid crystal on film speaker

  • Bae, Byeong-Taek;Park, Dong-Hee;Jeong, Kwang-Ho;Choi, Won-Kook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.877-878
    • /
    • 2009
  • To realize the flexible audible display (FAD), polymer dispersed liquid crystal(PDLC) is deposited on PVDF(Poly-vinylidene fluoride) film with piezoelectric property. With applied audio signal, it makes sound more than 70 dB in 700 Hz-10kHz. In case of transparency it is opaque and transmittance is less than 10% at 550nm wavelength without bias voltage. It is turned to be transparent and show transmittance of 66% with driving voltage of 60V.

  • PDF