• Title/Summary/Keyword: Audible

Search Result 264, Processing Time 0.026 seconds

Predicting formula development of audible noise on a 765kV AC transmission line(I) (765kV 교류 송전선로의 가청소음계산 예측식개발(I))

  • 이동일;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

The Audible Noise Prediction of the Substation due to Transformer Audible Noise and the Field Application of the Low Noise Transformer (변압기 소음에 의한 변전소 소음예측 및 저소음 변압기 현장적용)

  • Kweon, Dong-Jin;Koo, Kyo-Sun;Kim, Gyeong-Tak;Woo, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.8
    • /
    • pp.1382-1387
    • /
    • 2010
  • Recently, there has been a growing interest in the environmental conservation. Accordingly, problems related to the audible noise of transformers have became more frequent. Therefore, it is urgent to find a fundamental solution about the audible noises in the substations. This paper described a sort of fundamental solution to solve the noise problem. As a fundamental solution, we suggested the proper audible noise level of transformers through noise prediction in the substation construction phase. And we applied the low noise transformers which have the predicted noise level. As the result, we are able to satisfy the noise regulation through measuring 43.6dBA at the boundary of substation. It is confirmed that the average error rate of prediction was within 3 percent.

Development and Application of BLE-Based Audible Pedestrian Signal (APS) for Intersection Safety Crossing of Blind People (시각장애인의 교차로 안전횡단 지원 BLE 기반 음향신호기 개발 및 현장 적용사례)

  • Kim, Hyoung Sun;Kim, Ju Wan;Jang, In Sung
    • Journal of Information Technology Services
    • /
    • v.16 no.4
    • /
    • pp.223-234
    • /
    • 2017
  • The audible pedestrian signal (APS) is an add-on device which connects to the pedestrian signaling device and informs the contents and changes of the signaling by sound. It provides walking direction information of the pedestrian crossing so that the blind people can safely cross the pedestrian crossing. In an intersection where a plurality of audible pedestrian signal (APS) are installed at an intersection crosswalk, existing audible pedestrian signal (APS) operate simultaneously in the communication radius of a wireless remote controller, which may cause confusion for the blind people and the public may complain about the noise. In this paper, we developed a BLE (Bluetooth Low Energy)-based audible pedestrian signal (APS) system capable of supporting two-way communications with a smart-phone that can cross the intersection safely and improve the walking comfort and traffic safety for the blind people. The proposed method is a method in which the BLE beacon communication based audible pedestrian signal (APS) presents active service to the blind people, and the existing audible pedestrian signal (APS) is a way of requesting the passive service by the blind people with the wireless remote control by the unidirectional communication based on 358Mhz. The developed system is installed in the crossroad of Doma-dong, Seo-gu, Daejeon, and it is tested and operated by the blind people. The satisfaction evaluation and analysis of the audible pedestrian signal (APS) for the blind people have good results and are planned to be expanded in the future.

Development of AC Transmassion Line Audible Noise Prediction Formulas Using Evolutionary Computations

  • Yang, Kwang-Ho;Park, June-Ho;Hwang, Gi-Hyun;Kim, Jeong-Boo
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.6
    • /
    • pp.116-122
    • /
    • 1997
  • The audible noise produced by corona discharge in high voltage transmission lines is the most important line design consideration. In this paper, more accurate and useful formulas for predicting the A-weighted audible noise during heavy and light rain in alternative current (AC) transmission lines are proposed through comparison with the existing formulas. The proposed formulas are developed by the applications of evolutionary computations (ECs) to audible noise data base from long-term measurement.

  • PDF

An Analysis on the Audible Sound Due to Load and Cooling Fan for 154kV Power Transformers (154kV 전력용 변압기의 부하소음 및 냉각팬 소음 분석)

  • Koo, Kyo-Sun;Woo, Jung-Wook;Kwak, Joo-Sik;Kim, Gyeong-Tak;Kweon, Dong-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.298-304
    • /
    • 2010
  • Recently, the audible sound level of power transformer has been reduced due to development of new material and enhancement of manufacturing technology. There is lack of research on the audible sound of winding and cooling fan because the research on reduction of audible sound is concentrated on the core sound. Therefore this paper describes 3 kinds(core, winding and cooling fan) of transformer sound source. Also this paper analyzes the effect of load sound and cooling fan sound on the total transformer sounds. As the results, total sound level of 79dBA class transformer rises 0.2~0.3dB due to effect of load sound and rises 2.1~3.5dB due to effect of cooling fan sound. Also, total sound level of 55dBA class transformer rises 2.3~2.9dB due to effect of load sound and rises 1.9~3.5dB due to effect of cooling fan sound.

An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings (공동주택에서의 화재 경보음 전달특성에 관한 연구)

  • Lee, Min-Joo;Kim, Myung-Jun;Yoon, Myong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF

A New Approach far Reducing Audible Noise in Mobile TFT LCD Module (모바일 TFT-LCD 모듈에서 발생하는 가청잡음을 줄이기 위한 새로운 방법)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.06a
    • /
    • pp.540-543
    • /
    • 2007
  • In this paper, we propose a new approach to reduce the audible noise generated by TFT-LCD module in mobile applications. We also analyzed impact factors which effect on the audible noise. It is expected that this noise source comes from various impact factors such as vibration of flexible printed-circuit board (FPCB) and LCD panel, and static electricity charged in window and back-light unit. Windowless type and window type models are evaluated to analyze noise level due to the static electricity charged in window. To obtain reliable and reproducible data, we constructed controllable test jig and measurement set-up.

  • PDF

Electromagnetically Excited Audible Noise in Electrical Machines

  • Hameyer, Kay;Henrotte, Francois;Delaere, Koen
    • Journal of KSNVE
    • /
    • v.13 no.2
    • /
    • pp.109-118
    • /
    • 2003
  • With the rising utilisation of electrical machines to increase the output-Power of the device several problems occur. Next to probable additional losses and other parasitic effects, aspects concerning the audible noise radiated by the device are of particular interest. This contribution is intended to give an overview to the problematic of the analysis of vibrations and audible noise radiated by electrical machines. It is not the intention of the authors to set off a scientific firework with various complicated equations in this contribution. The paper should rather give an insight in a complicated technical matter and should help to understand the mechanism of vibration and parasitic noise generation in electrical machines. Rotating machines, such as the induction motor as well as non-rotating electrical machines, such as inductors or transformers are studied. The origin of vibrations leading to noise radiations is studied and discussed to illustrate the way in which the analysis of the governing effects can be performed. Magnetically generated radial pullout force waves in rotating electrical machines are the main cause of the excited audible noise, whereas magnetostriction plays an important role in transformers.

A Comparative Study on the Performance of Two-Phase and Three-Phase Randomized Pulse Position PWM Scheme for Mitigation of Audible Switching Acoustic Noise in Motor Drives (모터 구동 장치의 가청 스위칭 소음 저감을 위한 2상 및 3상 랜덤 펄스 위치 PWM기법의 성능 비교)

  • 정영국;위석오;나석환;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.3
    • /
    • pp.224-236
    • /
    • 2002
  • In this paper, a comparative study on the performance of two-phase and three-phase randomized pulse position PWM scheme for mitigation of audible switching acoustic noise in motor drives is done. In the randomized Pulse Position PW, each of two-Phase or three-phase PWM Pulses is located randomly in each switching interval. Simulation and experimental efforts were executed to investigate the spread effects of Power spectra of inverter output voltage, waveforms of ripple current and audible switching acoustic noise. As results, two-phase RP% scheme is more effective from the viewpoint of switching loss and ease of implementation while the three-phase RPWM scheme is more effective from the viewpoint of the spread effects of power spectra. Also, from the view point of the audible switching acoustic noise in motor drives, two-phase and three-phase RPW schemes are nearly the same.

Flexible audible display(VizDio$^{TM}$) using polymer dispersed liquid crystal on film speaker

  • Bae, Byeong-Taek;Park, Dong-Hee;Jeong, Kwang-Ho;Choi, Won-Kook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.877-878
    • /
    • 2009
  • To realize the flexible audible display (FAD), polymer dispersed liquid crystal(PDLC) is deposited on PVDF(Poly-vinylidene fluoride) film with piezoelectric property. With applied audio signal, it makes sound more than 70 dB in 700 Hz-10kHz. In case of transparency it is opaque and transmittance is less than 10% at 550nm wavelength without bias voltage. It is turned to be transparent and show transmittance of 66% with driving voltage of 60V.

  • PDF