• Title/Summary/Keyword: Attenuation relationship

Search Result 120, Processing Time 0.023 seconds

Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media (Barium 조영제의 농도 차이가 PET 검사에 미치는 영향)

  • Choi, Woo-Joon;Shin, Sang-Ki;Nam, Ki-Pyo;Park, Soon-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

Empirical Prediction Models of 1-min Rain Rate Distribution for Various Integration Time

  • Jung, Myoung-Won;Han, Il-Tak;Choi, Moon-Young;Lee, Joo-Hwan;Pack, Jeong-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.2
    • /
    • pp.84-89
    • /
    • 2008
  • In a wireless channel above microwave frequency, rain attenuation is very important. In order to predict rain attenuation, 1-min. rain rate distribution is required. This paper discusses appropriate conversion methods to estimate 1-minute rain rate from that of other integration time. Based on the measurement data filed in ITU-R WP3J including ETRI data for 6 consecutive years, distributions of rain rate with 1-, 5-, 10-, 20-, 30-minute integration time were analyzed, both on the global and regional basis, and the parametric relationship between the statistical characteristics of 1-minute and other measurement data were investigated to deduce the conversion methods. It is shown that the global model works good with good accuracy for 5-, 10-, 20-min integration time, and the global model is also applicable globally with good accuracy for 5-, 10-, 20-min integration time. The global conversion model was adopted last year as an ITU-R document for new recommendation. The regional conversion model would also be very useful for locations of similar climatic zone.

Correlation Analysis between Ultrasonic Parameters and Elastic Modulus of Apple

  • Kim, Ghi-Seok;Kim, Ki-Bok;Park, Jeong-Gil;Lee, Sang-Dae;Jung, Hyun-Mo;Kim, Man-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.3
    • /
    • pp.279-284
    • /
    • 2008
  • The firmness of fruit is one of the most important quality factors and is highly correlated to the elastic modulus. In this study, the ultrasonic transmission method was applied to evaluate the elastic modulus of the apple. In order to transmit and receive the ultrasonic wave through the whole apple, the ultrasonic measurement setup consisted of ultrasonic pulser, two specially fabricated ultrasonic transducers for fruit and digital storage oscilloscope. Ultrasonic parameters such as ultrasonic wave velocity, apparent attenuation, and peak frequencies were analyzed. The elastic modulus of apple was measured by using compression test apparatus. The correlations between ultrasonic parameters and elastic modulus were analyzed. A multiple linear regression model describing the relationship between elastic modulus and ultrasonic parameters was proposed.

Identifying Suspended Particulate Matters in an Urban Coastal System: Significance and Application of Particle Size Analysis

  • Ahn, Jong-Ho
    • Environmental Engineering Research
    • /
    • v.17 no.3
    • /
    • pp.167-174
    • /
    • 2012
  • In situ particle size spectra are obtained from two sequent cruises in order to evaluate the physical consequences of suspended particulate matters caused by episodic storm runoff from the Santa Ana River watershed, an urbanized coastal watershed. Suspended particles from various sources including surface runoff, near-bed resuspension, and phytoplankton are identified in empirical orthogonal function (EOF) analysis and an entropy-based parameterization (Shannon entropy). The first EOF mode is associated with high turbidity and fine particles as indicated by the elevated beam attenuation near the Santa Ana River and Newport Bay outlets, and the second EOF mode explains the suspended sediment dispersal and particle coarsening at the near-surface plume. Chlorophyll particles are also distinguished by negative magnitudes of the first EOF mode, which is supported by the relationship between fluorescence and beam attenuation. The integrated observation between the first EOF mode and the Shannon entropy index accentuates the characteristics of two different structures and/or sources of sediment particles; the near-surface plumes are originated from runoff water outflow, while the near-bottom particles are resuspended due to increased wave heights or mobilizing bottom turbidity currents. In a coastal pollution context, these methods may offer useful means of characterizing particle-associated pollutants for purposes of source tracking and environmental interpretation.

MONITORING THE BAY OF BENGAL AS A BALLAST WATER EXCHANGEABLE SEA USING MODIS/AQUA

  • Kozai, Katsutoshi;Ishida, Hiroshi;Okamoto, Ken;Fukuyo, Yasuyo
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.483-486
    • /
    • 2006
  • The study describes the monitoring of the Bay of Bengal as a ballast water exchangeable sea using MODIS/Aqua-derived diffuse attenuation coefficient (K(490)) synchronized with in situ ballast water sampling and analysis along the LNG carrier's route between Japan and Qatar from 2002 to 2005. Based on the relationship between K(490) and corresponding in situ plankton cell densities, the Bay of Bengal is recognized as a ballast water exchangeable sea to meet the regulation of ballast water performance standard of International Maritime Organization (IMO). Furthermore the Bay of Bengal with more than 200m depth and more than 200 nautical mile distance from shore is extracted based on the regulation of ballast water exchange area of IMO. However, an anomalously high K(490) area is found off the coast of Sri Lanka during the northeast monsoon in 2005, which corresponds higher cell densities than the criterion set by the regulation of IMO. The phenomenon of high cell density in the Bay of Bengal seems to be related with the phytoplankton bloom during the northeast monsoon. Seasonal and annual variability of phytoplankton bloom will be investigated to establish an early routing system for avoiding the high cell density area in advance.

  • PDF

Study on Hydrogen Effect in TIG Welded Stainless Steel (TIG 용접된 스테인리스강의 수소영향에 대한 연구)

  • Lee, Jin-Kyung;Lee, Sang-Pill;Bae, Dong-Su;Lee, Joon-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.58-63
    • /
    • 2016
  • A stainless steel has high corrosion resistance because of nickel in material, so it is used as materials for transportation and storage of hydrogen. In this study, TIG(tungsten ingot gas) welding was carried out on the stainless steel using the storage vessel of hydrogen. The microscopic structures at each region of TIG welded material such as HAZ, weld and base metals using optical microscope were observed. And the damage behavior of stainless steel that underwent the hydrogen charging using nondestructive evaluation was also studied. Ultrasonic test, which is the most generalized nondestructive technique, was applied to evaluate the relationship between the ultrasonic wave and mechanical properties at each zone of TIG welded stainless steel. The velocity and attenuation coefficients of ultrasonic wave didn't show a remarkable difference at each region of welded stainless steel. However, the attenuation coefficient was the highest at the weld zone when hydrogen charged stainless steel. In addition, acoustic emission test was also used to study the dynamic behavior of stainless steel experienced both hydrogen charging and weld. Lots of AE event at elastic region of stress-strain curve were occurred both the hydrogen charged specimen and the free specimen.

S-wave Velocity and Attenuation Structure from Multichannel Seismic surface waves: Geotechnical Characteristics of NakDong Delta Soil (다중채널 표면파 자료를 이용하여 구한 S파 속도와 감쇠지수 구조: 낙동강 하구의 연약 지반 특성)

  • Jung, Hee-Ok
    • Journal of the Korean earth science society
    • /
    • v.25 no.8
    • /
    • pp.774-783
    • /
    • 2004
  • The S wave velocity and Q$s^{-1}$ structure of the uppermost part of the soil in Nakdong Delta area have been obtained to determine the characteristics of the forementioned soil. The phase and attenuation coefficients of multichannel seismic records were inverted to obtain the S wave velocity and Q$s^{-1}$ structure of the soil. The inversion results have been compared with the borehole measurements of the area. The seismic signal of the nearest geophone from a seismic source was used as the source signal to obtain the attenuation coefficients. Amplitude ratios of the signal at each geophone to the source signal wave plotted as a function of distance for the frequency range between 10 Hz and 45 Hz. The slope of a linear regression line which fits amplitude ratio-distance relationship best for a given frequency was used as the attenuation coefficients for the frequency. The dispersion curve of Rayleigh waves and the attenuation coefficients were inverted to obtain the S-wave velocity and Q$s^{-1}$, respectively, in the uppermost 8 meter of soil layer. The borehole measurements of the area show that are two distinct layers; the upper 4 meter of silty-sand and the lower 4 meter of silty-clay. The inversion results indicate that the shear wave velocity of the upper layer is 80 m/sec and 40m/sec in the lower silty-clay layer. The spacial resolution of the shear wave velocity structure is very good down to a depth of 8 meter. The Q$s^{-1}$ in the upper silty-sand layer is 0.02 and increase to 0.03 in the lower silty-sand layer. The spacial resolution of quality factor is relatively good down to a depth of 5 meter, but very poor below the depth. In this study, the S-wave velocity is higher in the silty-clay and the Q$s^{-1}$ is smaller silty-sand than in the silty-clay. However, much more data should be analyzed and accumulated before making any generalization on the shear wave velocity and Q$s^{-1}$ of the sediments.

Ku Band Antenna G/T Analysis and Experiment According to Elevation Angle Change (앙각변동에 따른 Ku 밴드 안테나 G/T 분석 및 실험)

  • Lee, Kyung-Soon;Koo, Kyung-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.7
    • /
    • pp.550-559
    • /
    • 2017
  • In order to maintain communication while the vehicle is moving, satellite azimuth angle and elevation angle correction are needed in real time. The elevation angle correction affects the system G/T according to the variation of the external noise temperature flowing into the antenna. G/T is expressed as a ratio of power gain G to noise temperature T and is an important performance function required for antenna gain design. This paper aims to G/T analysis considering elevation angle change and the establishment of an antenna design procedure. For this purpose, the relationship between elevation angle and brightness temperature including rain attenuation was analyzed according to recommendation ITU-R P.372 radio noise. Next, an antenna was designed based on the analysis results and design procedure was verified by G/T measurement. Through this experiment, G/T according to elevation angle was confirmed, and the minimum antenna gain analysis and design procedure required in the system could be established.

Application of Nondestructive Technique on Hydrogen Charging Times of Stainless Steel 304L (스테인리스 304L강의 수소장입시간에 대한 비파괴기법 적용)

  • Lee, Jin-Kyung;Hwang, Seung-Kuk;Lee, Sang-Pill;Bae, Dong-Su;Son, Young-Seok
    • Journal of Power System Engineering
    • /
    • v.19 no.5
    • /
    • pp.60-66
    • /
    • 2015
  • Embrittlement of material by hydrogen charging should be cleared for safety of storage vessel of hydrogen and components deal with hydrogen. A stainless steel is generally used as materials for hydrogen transportation and storage, and it has a big advantage of corrosion resistance due to nickel component in material. In this study, microscopic damage behavior of stainless steel according to the hydrogen charging time using nondestructive evaluation was studied. The surface of stainless steel became more brittle as the hydrogen charging time increased. The parameters of nondestructive evaluation were also changed with the embrittlement of stainless steel surface by hydrogen charging. Ultrasonic test, which is the most generalized nondestructive technique, was applied to evaluate the relationship between the ultrasonic wave and mechanical properties of stainless steel by hydrogen charging. The attenuation coefficient of ultrasonic wave was increased with hydrogen charging time because of surface embrittlement of stainless steel. In addition, acoustic emission test was also used to study the dynamic behavior of stainless steel experienced hydrogen charging. AE event at the hydrogen charged specimen was obviously decreased at the plastic zone of stress-strain curves, while the number of event for the specimen of hydrogen free was dramatically generated when compared with the specimens underwent hydrogen charging.

Optical Properties of Sea Water - Entrance of Tokyo Bay , Japan ( 2 ) - (해수의 광학적 성질에 관한 연구 - 일본 동경만 입구 ( 2 ) -)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.2
    • /
    • pp.16-21
    • /
    • 1986
  • Optical properties of sea water were studied in the entrance of Tokyo Bay, Japan. based on the data obtained from seven oceanographic stations in June. 1985. The observation of surface irradiance and underwater irradiance of sea water for eight kind of wavelength (378, 422, 481, 513, 570, 621, 653. 677nm) of sun light was conducted using the underwater irradiameter (Isigawa # SR-8). The mean att;enuation coefficient of the sea water was appeared to be 0.245 (0.042-0.776) and the attenuation co~fficient of the sea water for wavelength appeared such as 0.227 for 378 nm, 0.186 for 422 nm. O. 175 for 481 nm. O. 176 for 513 nm. O. 185 for 570 nm, 0.337 for 621 nm. O. 321 for 653 nm, O. 348 for 677 nm. The transparency was 7.0 m (5.5-9 m). water color was 10 (8.0-13.0) in the study area and the sun altitude was 60.95$^{\circ}$ (43.610-75.500). The relationship between attenuation coefficient (K) and transparency (D) was K = 2.63/ D (1.28/ D- 4. 87/D). The rate of light penetration for eight kind of wave Ie nth (378, 422. 481. 513. 570, 621, 653, 677 nm) were computed with reference to the surface light intensity respectively. The mean rate of light penetration in proportion to depths were 68.63% (46.02-86.07%) in 1 m layer, 18.40% (2.07 -48.48%) in 5m layer, 4.82% (0.042-22.30%) in 10m layer and 1.35% (0.01I-7.42%) in 20m layer. The rate of light penetration at the transparency layer with reference to the surface light intensity was shown as 10.39% (0.77-27.46%).

  • PDF