• 제목/요약/키워드: Attenuation rate

검색결과 287건 처리시간 0.031초

창원-마산 지역에서의 강우에 의한 위성신호의 감쇠량 추정 (An Estimation of Rain Attenuation of Satellite Signal in Changwon-Masan)

  • 하연철;고봉진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.34-37
    • /
    • 1998
  • Signal Attenuation in the design of satellite channel is due mostly to rain. In this paper, the rain rate characteristics based on the recent year(1994-1996) data for Changwon-Masan were approximated to Moupfouma distribution, and the parameters of distribution were calculated from a simple conversion method of 1-h rate to 1-min rain rate data. From rain rate characteristics, the rain attenuation was estimated and compared with CCR model, Global model and SAM model.

  • PDF

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.340-345
    • /
    • 2003
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the relation between crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the results of experiments, the measurement method of crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

금속파편 충격 신호분석을 위한 굽힘파의 거리 감쇠 (Distance Attenuation of Bending Wave to Analyze the Loose Parts Impact Signal)

  • 이정한;박진호
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.594-601
    • /
    • 2016
  • Mass estimation analysis of loose-parts in pressure vessel is necessary for the structural integrity assessment of pressure boundary in nuclear power plants. Mass of loose-parts can be generally estimated from the peak values and the center frequency of impact signals. Magnitude of impact signals is, however, inevitably attenuated according to the traveling distance of the signals and depending on the frequencies. Attenuation rate must be therefore carefully compensated for the precise estimation of loose-part mass. This paper proposes a new compensation method for the attenuation rate based on Bessel function instead of Hankel function in conventional method which has a limitation of usage in near the impact location. It was verified that the suggested compensating equation based on the Bessel function can be applied to the attenuation rate calculation without any limitation.

Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials)

  • 박성일;정남용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정 (Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components)

  • 정남용;박성일
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

초음파 감쇠계수에 의한 균열길이의 측정 (Measurement of Crack Length by Ultrasonic Attenuation Coefficient)

  • 정남용;박성일
    • 대한기계학회논문집A
    • /
    • 제28권4호
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

Ka-대역 위성 통신의 위한 강우에 의한 전파 감쇠 예측 모델 (Prediction Model of Rain Attenuation for Ka-Band Satellite Communication)

  • 우병훈;강희조
    • 한국정보통신학회논문지
    • /
    • 제6권7호
    • /
    • pp.1038-1043
    • /
    • 2002
  • The demand for multimedia service using Ka-band satellite communication are growing rapi이y. So, in this paper, we have analyzed rain attenuation with typical model, and proposed prediction model of rain attenuation in high frequency(over 20[GHz]). Path loss model by rain attenuation is based upon rain rate of representative region(6 cities). Proposed prediction model of rain attenuation and parameter of satellite link can be available for the Ka-band satellite communication.

DETECTION OF INTERFACIAL CRACK LENGTH BY USING ULTRASONIC ATTENUATION COEFFICIENTS ON ADHESIVELY BONDED JOINTS

  • Chung, N.Y.;Park, S.I.
    • International Journal of Automotive Technology
    • /
    • 제5권4호
    • /
    • pp.303-309
    • /
    • 2004
  • In this paper, an interfacial crack length has been detected by using the ultrasonic attenuation coefficient on the adhesively bonded double-cantilever beam (DCB) joints. The correlations between energy release rates which were investigated by experimental measurement, the boundary element method (BEM) and Ripling's equation are compared with each other. The experimental results show that the interfacial crack length for the ultrasonic attenuation coefficient and energy release rate increases proportionally. From the experimental results, we propose a method to detect the interfacial crack length by using the ultrasonic attenuation coefficient and discuss it.

Measurement of Rainfall Characteristics and Rain-Attenuation at 38 GHz in Worst Months Affected by El Nino Signal in 1998

  • Jang Won-Gyu;Choi Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • 제5권4호
    • /
    • pp.189-192
    • /
    • 2005
  • The measurement of unique rainfall phenomenon and rain attenuation on 38 GHz terrestrial links at South Korea in 1998 is presented. It was one of the most severe rainfall years at the measured region due to increased EI Nino signal. The rainfall rate exceeded at $0.01\%$ was 97.4 mm/h during a worst month and annual rate was 63.5 mm/h. Experimentally measured results have been compared with some models and found that the rain attenuation by system level was underestimated by the existing prediction models. As it was measured only three months, further study and measurement of rainfall and rain attenuation in this region are needed for stable millimeter-wave system operation at all times.

노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법 (A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis)

  • 김성준;신현수;고승영;박혜리;김자영;이보미;예지원;김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제22권1호
    • /
    • pp.12-17
    • /
    • 2011
  • 본 연구는 노발리스용 치료테이블(couch top)을 투과하는 광자선의 감쇠율(attenuation rate)을 기하학적 모델을 통해 계산하고 보정함으로써, 치료부위에 정확한 선량이 전달되게 하는데 그 목적이 있다. 실험은 치료테이블을 투과하는 광자선의 투과율과 감쇠율을 기하학적인 모델에 의해 예측하고 이를 바탕으로 실험적으로 측정된 것을 비교 및 분석하였다. 그 결과 기하학적 모델에 의해 예측된 값과 실험값이 매우 잘 일치하는 것으로 나타났다. 또 실제 임상적용의 가능여부를 판단하기 위하여, 척추 방사선수술(spine radiosurgery)환자의 치료계획에 모델링화한 감쇠율을 보정한 뒤 측정한 중심점 선량과 그렇지 않은 것을 비교하였더니, 전자가 치료계획된 것과의 오차율이 감소함을 보였다. 본 논문에서는 치료테이블을 투과하는 광자선의 기하학적 모델을 통해 투과율과 감쇠율을 계산하고 이를 실험적으로 증명하였다. 이 방법은 노발리스를 이용한 방사선 수술뿐만 아니라 일반적인 방사선 치료에 있어서도 매우 유용할 것으로 판단된다.