• Title/Summary/Keyword: Attenuation of Noise

Search Result 478, Processing Time 0.025 seconds

A Study on the Control of Solenoid Valve for Heating by using Power Line Communication (PLC) (전력선 통신을 이용한 난방용 솔레노이드밸브 제어에 관한 연구)

  • 신관우;김용태;이윤섭
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.8
    • /
    • pp.647-650
    • /
    • 2003
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance, and selective possibility of frequency property. We designed the boiler temperature control system unit by using the PLC modem. We can avoid unnecessary heating of separate temperature control unit, and save the cost accordingly control stability of the proposed system is proven through the experiment.

One-Dimensional Numerical Study of Compression Wave Propagating in High-Speed Railway Tunnel (고속철도 터널내를 전파하는 압축파의 일차원 수치해석)

  • 김희동;엄용균;송미일태
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.5
    • /
    • pp.1280-1290
    • /
    • 1995
  • In order to investigate the compression wave propagating in a high-speed railway tunnel, a numerical calculation was applied to the wave phenomenon occurring in a model tunnel. Unsteady, one-dimensional inviscid or viscous flows were solved by an explicit TVD scheme, and the calculated flows were compared with the results of measurement in real tunnels. Tunnel noises caused by emission of the compression wave were characterized in terms of excess pressure of compression wave, pressure gradient in the wave front and width of the compression wave. Calculated attenuation, pressure gradient and width of compression wave with the propagating distance agreed with the results of measurement in the real tunnels. The results also show that tunnel noises are proportional to the train velocity entering the tunnel.

A Study on the Receiving Performance Improvement of Digital Mobile Communication (디지털 이동통신의 수신성능개선에 관한 연구)

  • 주재한
    • Journal of the Korea Computer Industry Society
    • /
    • v.2 no.11
    • /
    • pp.1477-1482
    • /
    • 2001
  • In this paper, we examined receiving parameters of receiver and also analyzed them through simulation based on J-STD-018, which is the minimum specification of PCS mobile station. Receiving system was made a passive double balance mixer which has low gain and high IIP3, and an intermediate frequency amplifier for enhancing the low gain. The result of simulating receiving parameter is as follows: noise figure which is the parameter of specification of the receiving sensitivity is 6.746dB, IIP3 which is the parameter of specification of the intermodulation spurious response attenuation is -11.358dBm.

  • PDF

Performance analysis of WPM-based transmission with equalization-aware bit loading

  • Buddhacharya, Sarbagya;Saengudomlert, Poompat
    • ETRI Journal
    • /
    • v.41 no.2
    • /
    • pp.184-196
    • /
    • 2019
  • Wavelet packet modulation (WPM) is a multicarrier modulation (MCM) technique that has emerged as a potential alternative to the widely used orthogonal frequency-division multiplexing (OFDM) method. Because WPM has overlapped symbols, equalization cannot rely on the use of the cyclic prefix (CP), which is used in OFDM. This study applies linear minimum mean-square error (MMSE) equalization in the time domain instead of in the frequency domain to achieve low computational complexity. With a modest equalizer filter length, the imperfection of MMSE equalization results in subcarrier attenuation and noise amplification, which are considered in the development of a bit-loading algorithm. Analytical expressions for the bit error rate (BER) performance are derived and validated using simulation results. A performance evaluation is carried out in different test scenarios as per Recommendation ITU-R M.1225. Numerical results show that WPM with equalization-aware bit loading outperforms OFDM with bit loading. Because previous comparisons between WPM and OFDM did not include bit loading, the results obtained provide additional evidence of the benefits of WPM over OFDM.

Characteristics Analysis of Powerline Channel for Powerline Communication (전력선 통신을 위한 채널 특성 분석)

  • Lee, J.H.;Seo, J.W.;Lee, J.J;Shin, M.C.;Sung, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.558-560
    • /
    • 2000
  • The role of power line is not limited to providing electrical power. Power line fumed out to be an candidate to cope with the existing communication channels. It is need to be measured the properties of power line as communication channels, before successful communication system is possible. This paper presents the characteristics of power line noise and attenuation measurements in the frequency range of $0{\sim}10$ MHz, and then suggests applicable communication techniques in brief. Power line channel is configured in our laboratory and the length of it is 250 meters.

  • PDF

Study on enhancing the ultrasonic image for bone densitometry (골밀도 측정을 위한 초음파 영상 개선에 관한 연구)

  • Shin, Jung-Sik;Ahn, Jung-Hwan;Kim, Hyung-Joon;Kim, Hwa-Young;Han, Seung-Moo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.8 s.173
    • /
    • pp.182-191
    • /
    • 2005
  • It is very important to obtain a high quality of bone image for an accurate ultrasonic measurement of bone mineral density. In this study, we suggested a technique to acquire an optimal image by adapting an acoustic lens and a properly selected ultrasonic probe. Also, we have applied an image processing algorithm with which automatically makes a decision of brightness and contrast of image by generating threshold level, a composition of ultrasonic data, an elimination of noise using modified median filter, and a real time interpolation. We could confirm much improved resolution of bone image with acoustic lens attached to the ultrasonic probe and with the image processing algorithm suggested in this study. Therefore, it became possible to precisely diagnose the osteoprosis using ultrasonic imaging technique.

Robust Vibration Control for a Building with Parameter Uncertainty (파라미터 불확실성을 고려한 건물의 견실 진동 제어)

  • 최재원;김신종;이만형
    • Journal of KSNVE
    • /
    • v.10 no.4
    • /
    • pp.575-583
    • /
    • 2000
  • In this paper, we design a vibration control system that includes a 3-D.O.F. mass-spring-damper structure for the analytical model of a building that is excited at the base of this structure by an external dynamic force, and one Active Mass Damper(AMD) on the top of this structure to generate control forces fro attenuation of the structural response. Two robust controllers based on $\mu$-synthesis and H$\infty$ optimal control are designed for the structural system to show that the performance of a control system can be degraded by some parameter uncertainties such as mass, stiffness coefficients, and/or damping coefficients. The performance of the two controllers are compared in terms of nominal performance, robust stability and robust performance by simulations.

  • PDF

Design of Improved EMI Filter (개선된 EMI Filter 설계 및 제작)

  • 배대환;구동우;김동일;송재만
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.4
    • /
    • pp.798-806
    • /
    • 2001
  • As electronic industry and radio communication technologies progress, the electrical and electronic equipments are lightened, minimized, and operated by low power. At the same time, these equipments react sensitively by electromagnetic wave noise. It is a origine these equipments to wrong-operation. In this paper, we focused on the design and preperation condition of a advanced EMI filter. This filter sowed superior attenuation effect of 10 dB~20 dB compare with typical filter in the range of frequency from 150 kHz to 30 GHz and superior character over the variation of a load.

  • PDF

Influence of HAPS and GEO Satellite under SANDU Layering and Gas Attenuations

  • Harb, Kamal
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12
    • /
    • pp.93-100
    • /
    • 2021
  • Satellite communication for high altitude platform stations (HAPS) and geostationary orbit (GEO) systems suffers from sand and dust (SANDU) storms in desert and arid regions. The focus of this paper is to propose common relations between HAPS and GEO for the atmospheric impairments affecting the satellite communication networks operating above Ku-band crossing the propagation path. A double phase three-dimensional relationship for HAPS and GEO systems is then presented. The comparison model present the analysis of atmospheric attenuation with specific focus on sand and dust based on particular size, visibility, adding gas effects for different frequency, and propagation angle to provide systems' operations with a predicted vision of satellite parameters' values. Thus, the proposed system provides wide range of selecting applicable parameters, under different weather conditions, in order to achieve better SNR for satellite communication.

H Control on the Optical Image Stabilizer Mechanism in Mobile Phone Cameras (이동통신 단말기 카메라의 손떨림 보정 장치의 H 제어)

  • Lee, Chibum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.266-272
    • /
    • 2014
  • This study proposes a closed-loop shaping control method with $H_{\infty}$ optimization for optical image stabilization (OIS) in mobile phone cameras. The image stabilizer is composed of a horizontal stage constrained by ball bearings and actuated by the magnetic force from voice coil motors. The displacement of the stage is measured by Hall effect sensors. From the OIS frequency response experiment, the transfer function models of the stage and Hall effect sensor were identified. The weight functions were determined considering the tracking performance, noise attenuation, and stability with considerable margins. The $H_{\infty}$ optimal controller was executed using closed-loop shaping and limiting the controller order, which should be less than 6 for real-time implementation. The control algorithm was verified experimentally and proved to operate as designed.