• Title/Summary/Keyword: Attenuation Measurement

Search Result 392, Processing Time 0.045 seconds

A Study on the Characteristics of Railroad Traffic Noise (철도교통소음의 특성에 관한연구)

  • Choi, Hyung-Il;Park, Sang-Ill;Yeom, Dong-Ick
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.771-778
    • /
    • 2007
  • This study has been conducted to achieve the following objectives: First, in order to understand the horizontal propagation and attenuation characteristics for the railroad traffic noise, we selected areas within 100 meters away from the railroad and then selected Saemaul-ho and Mugoongwha-ho as the subjects for our experiment. In this way, we analyzed the horizontal propagation and attenuation characteristics for the traffic noise occurring in diversified areas. Second, in order to understand the vertical propagation and attenuation characteristics for the railroad traffic noise, we measured and analyzed the distributional characteristics of vertical sound pressure levels on each floor of multi-storied apartment buildings according to changes of traffic load and types, and the existence or nonexistence of soundproof walls. For the case of the railroad traffic noise, we also selected Samaul-ho and Mugoongwha-ho as the subjects for our experiment, and we measured and analyzed the different noise levels on each floor of multi-storied apartment buildings from the soundproof wall. The results of Horizontal propagation and attenuation characteristics for the railroad traffic noise are as follows: In cases of the flat land, cutting land, and bridge area, as distance increases, the sound pressure level steadily decreases. The sound pressure level for the bridge area is higher than that of the flat land with a measurement of $5.5{\sim}10.2\;dB(A)$. Vertical propagation and attenuation characteristics for the railroad traffic noise are as follows: The amount of sound pressure level decrease is $14.2{\sim}14.8\;dB(A)$ for Samaul-ho and $13.5{\sim}14.3\;dB(A)$ for Mugoongwha-ho when measuring the vertical sound pressure levels at heights lower than 4.5 m, which indicates a fairly large decrease. At 6 m, the amount of decrease is 8.6 dB(A) for Samaul-ho and 8.2 dB(A) for Mugoongwha-ho, which indicates a small decrease.

A Study on the High Frequency Ultrasonic Attenuation Characterization in Artificially Aging Degraded 2.25Cr-1Mo Steel (2.25Cr-1Mo 강 인공 열화재의 고주파수 초음파 감쇠특성에 관한 연구)

  • Park, Ik-Keun;Park, Un-Su;Kim, Chung-Seok;Kim, Hyun-Mook;Kwun, Sook-In;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.4
    • /
    • pp.439-445
    • /
    • 2001
  • The destructive method is reliable and widely used lot the estimation of material degradation but, it have time-consuming and a great difficulty in preparing specimens from in-service industrial facilities. Therefore, the estimation of degraded structural materials used at high temperature by nondestructive evaluation such as electric resistance method, replica method, Barkhausen noise method, electro-chemical method and ultrasonic method are strongly desired. Ultrasonic nondestructive evaluation technique has been reported good to attain efficiency of measurement, high sensitivity of measurement, and rapidity and reliability of result interpretation. In this study, it was verified experimentally the feasibility of the evaluation of degraded 2.25Cr-1Mo steel specimens which were prepared by the isothermal aging heat treatment at $630^{\circ}C$ by high frequency longitudinal wave method investigating the change of attenuation coefficient by FFT analysis and wavelet transform. Because of carbide precipitation increase and spheroidization near grain boundary of microstructure to aging degradation, attenuation coefficient had a tendency to increase as degradation proceeded. It was identified possibly to evaluate degradation using the characteristics of high-frequency ultrasonics. Frequency dependence of ultrasonic attenuation coefficient to aging degradation appeared large, which made sure that attenuation coefficient is an important parameter for evaluation of aging degradation.

  • PDF

REVIEW OF GROUNDWATER CONTAMINANT MASS FLUX MEASUREMENT

  • Goltz, Mark N.;Kim, Seh-Jong;Yoon, Hyouk;Park, Jun-Boum
    • Environmental Engineering Research
    • /
    • v.12 no.4
    • /
    • pp.176-193
    • /
    • 2007
  • The ability to measure groundwater contaminant flux is increasingly being recognized as crucial in order to prioritize contaminated site cleanups, estimate the efficiency of remediation technologies, measure rates of natural attenuation, and apply proper source terms to model groundwater contaminant transport. Recently, a number of methods have been developed and subsequently applied to measure contaminant mass flux in groundwater in the field. Flux measurement methods can be categorized as either point methods or integral methods. As the name suggests, point methods measure flux at a specific point or points in the subsurface. To increase confidence in the accuracy of the measurement, it is necessary to increase the number of points (and therefore, the cost) of the sampling network. Integral methods avoid this disadvantage by using pumping wells to interrogate large volumes of the subsurface. Unfortunately, integral methods are expensive because they require that large volumes of contaminated water be extracted and managed. Recent work has investigated the development of an integral method that does not require extraction of contaminated water from the subsurface. We begin with a review of the significance and importance of measuring groundwater contaminant mass flux. We then review groundwater contaminant flux measurement methods that are either currently in use or under development. Finally, we conclude with a qualitative comparison of the various flux measurement methods.

A Comparative Study on Gamma-ray Measurement and MCNP Simulation for Precise Measurement of Spent Nuclear Fuel Burnup

  • Sohee Cha;Kwangheon Park
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.22 no.2
    • /
    • pp.129-137
    • /
    • 2024
  • To non-destructively determine the burnup of a spent nuclear fuel assembly, it is essential to analyze the nuclear isotopes present in the assembly and detect the neutrons and gamma rays emitted from these isotopes. Specifically, gamma-ray measurement methods can utilize a single radiation measurement value of 137Cs or measure based on the energy peak ratio of Cs isotopes such as 134Cs/137Cs and 154Eu/137Cs. In this study, we validated the extent to which the results of gamma-ray measurements using cadmium zinc telluride (CZT) sensors based on 137Cs could be accurately simulated by implementing identical conditions on MCNP. To simulate measurement scenarios using a lead collimator, we propose equations that represent radiation behavior that reaches the detector by assuming "Direct hit" and "Penetration with attenuation" situations. The results obtained from MCNP confirmed an increase in measurement efficiency by 0.47 times when using the CZT detector, demonstrating the efficacy of the measurement system.

Measurements of Ultrasound Attenuation Coefficient at Various Suspended Sediment Concentrations (부유물 농도 변화에 따른 초음파 신호의 감쇠계수 측정)

  • Lee, Changil;Choi, Jee Woong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2014
  • Coastal water including estuaries has distinctive environmental characteristics where sediments are transported and deposited by flowing river water, providing an environment in which fluid mud layers can be formed. Acoustic method is mostly used to detect or monitor the fluid mud layer. However, since sound propagating in this layer suffers severe attenuation, it is important to estimate the accurate attenuation coefficient for various concentrations of fluid mud layer for the successful use of the acoustic method. In this paper, measurement results of attenuation coefficient for 3.5, 5, and 7.5 MHz ultrasounds were presented. The measurements were made in a small-size water tank in which suspended sediment samples with various sediment concentrations were formed using kaolinite powder. The results were compared to the model predictions obtained by attenuation coefficient model in which the mean grain size (called as Mass-median-diameter, D50) was used as input parameter. There were reasonable agreements between measured attenuation coefficients and model outputs predicted using the particle range of D50 ${\pm}20%$. The comparison results imply that although the suspended sediments consist of various-sized particles, sound attenuation might be greatly influenced by amount of particle with a size which has a larger attenuation than that of any particle in the suspended sediments for the frequency used.

Feasibility Study on Surface Microcrack Detection of the Steel Wire Rods Using Electromagnetic Acoustic Resonance (전자기 음향 공진을 이용한 강선의 표면 미세 결함 탐상 타당성 연구)

  • Heo, Taehoon;Cho, Seung Hyun;Ahn, Bongyoung;Lim, Zhong Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.7-13
    • /
    • 2013
  • The surface microcrack over a few tens of micrometers is one of severe problems of a steel wire rod to lead to the failure of the final products, so the method to evaluate crack depth has been required to develop. This work investigates the feasibility of electromagnetic acoustic resonance (EMAR) for this problem. EMAR is the method for measurement of resonant features using electromagnetic acoustic transducer (EMAT). Generally, EMAR is sensitive to small variation of the structures and easy to apply it to the industrial field because of the feature of noncontact measurement. Through several EMAR experiments, the change of the resonant frequencies and attenuation in reverberation has been observed. The results confirms that the surface cracks of around 100 micrometer depth can be detected successfully with the present method.

Measurement Allocation by Shapley Value in Wireless Sensor Networks

  • Byun, Sang-Seon
    • Journal of information and communication convergence engineering
    • /
    • v.16 no.1
    • /
    • pp.38-42
    • /
    • 2018
  • In this paper, we consider measurement allocation problem in a spatially correlated sensor field. Our goal is to determine the probability of each sensor's being measured based on its contribution to the estimation reliability; it is desirable that a sensor improving the estimation reliability is measured more frequently. We consider a spatial correlation model of a sensor field reflecting transmission power limit, noise in measurement and transmission channel, and channel attenuation. Then the estimation reliability is defined distortion error between event source and its estimation at sink. Motivated by the correlation nature, we model the measurement allocation problem into a cooperative game, and then quantify each sensor's contribution using Shapley value. Against the intractability in the computation of exact Shapley value, we deploy a randomized method that enables to compute the approximate Shapley value within a reasonable time. Besides, we envisage a measurement scheduling achieving the balance between network lifetime and estimation reliability.

Study on the Sensivivity Difference Measurement by Ultrasonic Testing (초음파탐상(超音波探傷)에서의 감도차(感度差) 측정(測定) 연구(硏究))

  • Chung, Yong-Moo;Ann, Hee-Sung;Lee, Yun-Peel
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.2 no.1
    • /
    • pp.5-9
    • /
    • 1982
  • Experiments were performed according to ultrasonic attenuation measurement and comparison method of DAC curve to analyze the difference between PSI and 2nd ISI ultrasonic testing results. Smaller error was found by comparison method of DAC curve, and that method was more useful practically.

  • PDF

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

Development of the IRIS Collimator for the Portable Radiation Detector and Its Performance Evaluation Using the MCNP Code (IRIS형 방사선검출기 콜리메이터 제작 및 MCNP 코드를 이용한 성능평가)

  • Ji, Young-Yong;Chung, Kun Ho;Lee, Wanno;Choi, Sang-Do;Kim, Change-Jong;Kang, Mun Ja;Park, Sang Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.55-61
    • /
    • 2015
  • When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or the rapid response to the nuclear accident, several collimators with the different inner radii should be prepared according to the level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. In this study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same method used in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layers with different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performance evaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of the collimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiation detector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incident photon to the detector without replacing the collimator.