• Title/Summary/Keyword: Attenuation Measurement

Search Result 392, Processing Time 0.021 seconds

Calculation of Renal Depth by Conjugate-View Method Using Dual-head Gamma Camera (이중 헤드 감마 카메라를 이용한 Conjugate-View 계수법에 의한 신장 깊이 도출)

  • Kim, Hyun-Mi;Suh, Tae-Suk;Choe, Bo-Young;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.378-388
    • /
    • 2001
  • Purpose: In this study, we developed a new method for the determination of renal depth with anterior and posterior renal scintigrams in a dual-head gamma camera, considering the attenuation factor $e^{-{\mu}x}$ of the conjugate-view method. Material and Method: We developed abdomen and kidney phantoms to perform experiments using Technetium-99m dimercaptosuccinic acid ($^{99m}Tc$-DMSA). The phantom images were obtained by dual-head gamma camera equipped with low-energy, high-resolution, parallel-hole collimators (ICONf, Siemens). The equation was derived from the linear integration of omission ${\gamma}$-ray considering attenuation from the posterior abdomen to the anterior abdomen phantom surface. The program for measurement was developed by Microsoft Visual C++ 6.0. Results : Renal depths of the phantoms were derived from the derived equations and compared with the exact geometrical values. Differences between the measured and the calculated values were the range of 0.1 to 0.7 cm ($0.029{\pm}0.15cm,\;mean{\pm}S.D.$). Conclusion: The present study showed that the use of the derived equations for renal depth measurements, combined with quantitative planar imaging using dual-head gamma camera, could provide more accurate results for individual variation than the conventional method.

  • PDF

Role of $Na^+\;-K^+$ Pump on Endothelium-dependent Relaxation

  • Sung, Sang-Hyun;Roh, Joon-Ryang;Park, Tae-Sic;Suh, Suk-Hyo;Hwang, Sang-Ik;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.27 no.2
    • /
    • pp.199-207
    • /
    • 1993
  • To study the underlying mechanism through which the endothelium-dependent relaxation is inhibited by blocking the $Na^+\;-K^+$ pump, the effects of $Na^+\;-K^+$ pump blockade on the release of EDRF and its relaxing activity were examined, using organ bath study, bioassay technique, and cGMP measurement. Endothelium-dependent relaxation was attenuated by blocking the $Na^+\;-K^+$ pump in the vascular ring with intact endothelium. In bioassay experiment EDRF release was decreased with the blockade of the $Na^+\;-K^+$ pump in the EDRF donor strip. Endothelium-dependent increase of cGMP level was suppressed by inhibiting the $Na^+\;-K^+$ pump in the test strips. The magnitude of relaxation of test strip which was induced by the perfusate that had passed through the EDRF donor strip was decreased with the blockade of the $Na^+\;-K^+$ pump in the test strip. Therefore, it could be suggested that the attenuation of endothelium-dependent relaxation caused by inhibiting $Na^+\;-K^+$ pump activity is due to both the decreased release of EDRF from endothelial cells and the decreased sensitivity of the smooth muscle cells to EDRF.

  • PDF

Deterioration Diagnosis of Epoxy Mold-type Transformer Using Ultrasonic Waves (초음파를 이용한 에폭시 몰드변압기의 열화 진단)

  • 이상우;김인식;이동인;이광식;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.73-81
    • /
    • 1999
  • Measurements of ultrasonic signals caused by partial discharges were perlonnrl by using an ultrasonic measurement technique to diagnose the electrical treeing deterioration in an epoxy mold-type power transformer. We also examined the characteristics of tree growth, partial discharge magnitude and ultrasonic pulse number with the increase of the deterioration time. From these results, it was found that the shape of the tree was a branch-type, and the rates of the tree growth were examined when ac voltages of 16[kV] and 20[kV] were applied Ultrasonic pulse number and discharge magnitude were rapidly increased as the length of the tree grows after the middle stage of the deterioration time, and it appeared that ultrasonic pulse number was proportional to discharge magnitude. Attenuation, time-delaying and directivity characteristics of ultrasonic signals propagated into epoxy resin by using ultrasonic oscillation and receiving systems are also re[prted as a basic data of ultrasonic mesasurements in mold-type power transformer.former.

  • PDF

Study on the Feasibility of High-Temperature Immersion Ultrasonic Sensor with a Strip Waveguide (도파띠를 이용한 고온 액침 초음파센서의 가능성 연구)

  • Choi, M.S.;Lee, J.P.;Jung, T.E.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.151-156
    • /
    • 1994
  • Exertion has been made to develop high-temperature (about $250{\sim}650^{\circ}C$) immersion ultrasonic sensor for the visualization of objects, temperature measurement, dimensional check, or nondestructive testing of welds under liquid sodium. In this study, the feasibility of the ultrasonic sensor taking advantage of a strip waveguide was confirmed by water-experiment. The lowest order of antisymmetric Lamb wave was used in the frequency range with negligible dispersion. This plate wave was excited in the stainless steel strip waveguide of 1.0mm thickness and 13mm width by the comb-structure transducer of 2.3MHz frequency. Its attenuation coefficient was 1.2dB/m in air and 380dB/m in water. The signal to noise ratio of 25dB was obtained from a planar reflector 270mm away from the beam aperture of $13mm{\times}39mm$ size.

  • PDF

Dose Distributions in a Shielded Vaginal Cylinder using a HDR Co-60 Source (고선량 Co-60 선원이용시 차폐된 질 원주기구의 영향)

  • 김진기;김정수;김형진;권형철;강정구
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 1997
  • The present work is determine to the dose distribution reduced by the insertion of a shielded into a vaginal cylinder around a $\^$60/CO source in brachytherapy, and to the source calibration. It was investigated by measuring the relative dose around a 2.5cm diameter shielded vaginal cylinder in a polystyrene phantom by use of a ionization chamber. Measurements were made with the cylinder unshielded and 0.55cm thick 90$^{\circ}C$ lead shields inserted. Also, the dose distribution compared measurement value with calculation value according to the device manufacturer and the multiple-divided dose tables. A reduction in dose was observed on the unshielded side of the cylinder which increased with distance from the source and it does 4.4% within 1cm from the surface of the cylinder. On the shielded side of the cylinder, the dose at the surface is reduced to about 20.4% of its value without the shield. The effective attenuation factor entered for the 90$^{\circ}C$ lead shielded cylinder was average 0.2 in a $\^$60/CO moving source. In comparision with the dose calculation mathods, the multiple-divided dose tables are difference less than ${\pm}$4.1% with measured data in a $\^$60/Co source.

  • PDF

A Case Study on the Construction of Concrete Structures in Parallel with Tunnel Blasting (터널발파-구조물 병행시공을 위한 영향평가 연구)

  • 류창하;최병희;김양균;유정훈
    • Explosives and Blasting
    • /
    • v.21 no.4
    • /
    • pp.11-21
    • /
    • 2003
  • An experimental study was carried out in order to reduce the period and cost of construction of Missiryung tunnel, which is a relatively long one 3.6 km long. An allowable vibration level for curing concrete was established based on the extensive case studies done over the world. and assessment was performed on the possibility of constructing concrete structures like lining during tunnel blasting. Attenuation relationships were obtained by processing more than 130 measurement data from a series of tunnel blasting in the site. A Guideline for safe construction work was suggested. To verification, low small concrete blocks with a constant standoff distance were installed in the floor of the tunnel After the blocks were exposed to blast vibrations for 28 days, compressive strength tests were performed on 20 specimens taken from the blocks. It was shown that the suggested guideline was appropriate for the safe construction work at the site.

Characterization of Nitrate Contamination and Hydrogeochemistry of Groundwater in an Agricultural Area of Northeastern Hongseong (홍성 북동부 농촌 지역 지하수의 질산성 질소 오염과 수리지구화학적 특성)

  • Ki, Min-Gyu;Koh, Dong-Chan;Yoon, Heesung;Kim, Hyun-Su
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.3
    • /
    • pp.33-51
    • /
    • 2013
  • Spatial and temporal characteristics of nitrate contamination and hydrogeochemical parameters were investigated for springs and surficial and bedrock groundwaters in northeastern part of Hongseong. Two field investigations were conducted at dry and wet seasons in 2011 for 120 sites including measurement of field parameters with chemical analyses of major dissolved constituents. Nitrate concentrations were at background levels in springs while 45% of bedrock groundwater and 49% of surficial groundwater exceeded the drinking water standard of nitrate (10 mg/L as $NO_3$-N). The difference in nitrate concentrations between surficial and bedrock groundwater was statistically insignificant. Cumulative frequency distribution of nitrate concentrations revealed two inflection points of 2 and 16 mg/L as $NO_3$-N. Correlation analysis of hydrogeochemical parameters showed that nitrate had higher correlations with Sr, Mg, Cl, Na, and Ca, in surficial groundwater in both dry and wet season. In contrast, nitrate had much weaker correlations with other hydrogeochemical parameters in bedrock groundwater compared to surficial groundwater and had significant correlations only in wet season. Temporally, nitrate and chloride concentrations decreased and dissolved oxygen (DO) increased from dry season to wet season, which indicates that increased recharge during the wet season affected groundwater quality. Aerobic conditions were predominant for both surficial and bedrock groundwater indicating low natural attenuation potential of nitrate in the aquifers of the study area.

Antioxidant Effects of Ascorbic Acid on Renal-Ischemia Reperfusion Injury in Rabbit Model

  • Kim, Jong-Man;Lee, Jae-Yeon;Kim, Duck-Hwan;Jeong, Seong-Mok;Park, Chang-Sik;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.25 no.3
    • /
    • pp.165-169
    • /
    • 2008
  • Renal ischemia-reperfusion (I/R) injury is great clinical important because viability of the organ depends on the tolerance to ischemia-reperfusion injury, an inevitable processing during surgery. The purpose of this study was to investigate the effects of premedicated ascorbic acid alone in I/R injury model induced by cross-clamping of renal vessels. In the rabbit models, 2-4 kg New Zealand white rabbits were subjected to 30 minutes of warm unilateral renal ischemia followed by removal of contralateral kidney and then divided into five groups, control (2) arid treatment groups (3). In control group 1, the rabbits only received right nephrectomy. In control group 2, the rabbits received I/R on left kidney after the right nephrectomy. In treatment group 1, the rabbits received ascorbic acid 50 mg/kg IV before the operation. In treatment group 2, the rabbits received ascorbic acid 100 mg/kg IV before the operation. In treatment group 3, the rabbits received ascorbic acid 200 mg/kg IV before the operation. Blood samples were collected from these rabbits for measurement of kidney function tests at the 0, 1 st, 3rd and 7th day and antioxidant enzyme( SOD, GSHPx, CAT) at 24 hours. Kidney function tests (serum creatinine and BUN) showed a significant difference between group 2 and group 4, 5. Activity of antioxidant enzymes in plasma were significant decrease in group 4, 5 compare to group 2. The result of this study suggested that the exogenous ascorbic acid had a role of attenuation of renal I/R injury in rabbit model.

DESIGN AND FABRICATION OF S-BAND DIPLEXER FOR LEO TT&C APPLICATION (저궤도 위성 관제용 S-대역 다이플렉서 설계 및 제작)

  • Ahn, Sang-Il;Park, Dong-Chul
    • Journal of Astronomy and Space Sciences
    • /
    • v.24 no.4
    • /
    • pp.397-408
    • /
    • 2007
  • Diplexer is one of core devices needed to communicate with satellite using single ground antenna by separating uplink and downlink signal. This paper presents the design of the S-band diplexer for LEO TT&C application, especially for KOMPSAT (KOrea Multi-Purpose SATellite). To cope with requirements such as high handling power, low insertion loss, air-cavity resonator with high quality factor was considered as one of design drivers. Design was started with predicting unloaded Q and equivalent circuit from the structure of air-cavity resonator. For the convenience of adjustment, the coupling factor placed between resonators was estimated from COTSEM (Electro-Magnetic) simulator, EESOF $ADS^{TM}$, and expressed with 2-order polynomial regression. To improve the isolation between transmitting part (Tx) and receiving part (Rx), the inductive and capacitive attenuation poles were inserted between $4^{th}\;and\;6^{th}$ resonator respectively. The fabricated diplexer consists of two bandpass filters and each filter has eight resonants. From the measurement, it was shown that major requirements such as 0.5dB of insertion loss, 20dB of return loss and 100dB of isolation were fully satisfied within passband.

Design of the 1.8GHz Strip-line Isolator with high attenuations at harmonic band (고조파 대역에서 높은 감쇄를 갖는 1,8GHz 대역 스트립라인 아이솔레이터 설계)

  • Yoo, Young-Cheol;Eom, Ki-Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.4
    • /
    • pp.795-802
    • /
    • 2011
  • In this paper, the detailed design procedure of the Y-junction stripline isolator self-contained the filter circuit in the center conductor in order to maximize attenuations below value of 30 dB at 3rd order harmonics is presented. The HFSS is used to simulate 1.8GHz band isolator and the results are compared with the measurement data. These results confirms that the designed stripline isolator is effective in achieving high attenuation above -30 dB at 3rd order harmonics. And it is obtained that the harmonic band of isolator using the ferrite of 0.16T is moved far from operating frequency more 1.2 GHz than one using the ferrite of 0.12T.