• 제목/요약/키워드: Attemperator

검색결과 5건 처리시간 0.015초

화력발전소에서 과열저감기의 증기온도제어 (Steam Temperature Control of Attemperator in Thermal Power Plant)

  • 신휘범
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.40-48
    • /
    • 2011
  • An attemperator is a part of the 4-stage superheater in the boiler system of the thermal power plant. The attemperator receives the over-heated steam and makes the steam with proper temperature by adjusting the control valve of the cold steam. In this paper, the attemperator is modeled considering physical point of view and the linearized model is derived for the control purpose. To overcome the integral windup phenomenon due to the opening limitation of the control valve, an anti-windup PI controller is proposed to the attemperator and compared with the PI controller operated in the thermal power plant in view of control performance.

재열기 온도조절 급수배관의 진동저감방안 연구 (A Study on Vibration Control for Reheater Attemperator Piping in Power Plant)

  • 전창빈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1-5
    • /
    • 2007
  • A majority of piping vibration problems are induced by internal fluid pulsation; turbulent flow, vortex shedding at internal discontinuities, and pressure pulsation at equipment nozzles. The pulsation at the pressure sources resonates acoustically with the piping and the amplified pressure pulsation can generate shell mode vibration in the piping. Reheater attemperator piping supplies water from feedwater pump to reheater attemperator to control the boiler temperature. In normal operating condition, the high frequency shell mode vibration occurred in the piping with the high level of sound(105 ${\sim}$ 117 dB). The vibration sources are pressure pulsation in the pump nozzle and the frequencies are related to the blade passing frequencies. The objects of this paper are to analyze the cause of the high frequency vibration and to establish corrective actions.

  • PDF

증기발전 시스템의 과도상태 특성 해석 (Analysis of Transient Characteristics of a Steam Power Plant System)

  • 박근한;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.967-975
    • /
    • 2000
  • Transient characteristics of a boiler and turbine system for a steam power plant are simulated. One-dimensional unsteady models are introduced for each component. An interaction between boiler and turbine and a control of the water level in the drum are taken into account. Transient responses of the system to the variations of main system variables such as fuel and air flow rate, cooling water injection rate at the attemperator, gas recirculation rate at the furnace and opening of the turbine control valve are examined. Effect of fluid inertia and tube wall thermal inertia on predicted dynamic behavior is investigated.

GRNN 알고리즘을 이용한 화력발전소 보일러 증기계통의 모델링에 관한 연구 (Modeling of Boiler Steam System in a Thermal Power Plant Based on Generalized Regression Neural Network)

  • 이순영;이정훈
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.349-354
    • /
    • 2022
  • 화력발전소의 보일러 모델은 로직도 작성, 플랜트 튜닝, 제어이론 적용 등 다양한 분야에 사용된다. 특히 정확한 제어를 위해서는 정확한 모델이 필요하다. 수학적 모델은 화력발전소 시스템의 비선형성, 복잡성, 시변특성 등으로 인하여 시스템을 정확하게 표현하는데 한계가 있다. 이런 시스템에 대하여 신경망을 이용한 모델링 방법은 좋은 대안이 될 수 있다. 본 논문에서는 화력발전소 보일러의 증기계통을 신경망 알고리즘의 한 종류인 GRNN을 이용하여 모델링하였다. 보일러의 과열기와 재열기, 과열저감기, 드럼을 모델링하여 540[MW]급 화력발전소에서 취득한 데이터를 이용하여 학습하고 검증하였다. 검증결과 제안한 모델의 출력이 보일러의 실제 출력과 잘 일치함을 알 수 있었다.

관류보일러 물-증기 계통의 동적 시뮬레이션 - 아임계 동력보일러 사례 - (Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case -)

  • 김성일;최상민
    • 대한기계학회논문집B
    • /
    • 제41권5호
    • /
    • pp.353-363
    • /
    • 2017
  • 부하변동과 외란에 따른 관류보일러 물-증기 계통의 동적 거동을 물리적 모델링 접근방법으로 모사하였다. 본 논문에서는 수관의 질량, 에너지와 운동량 방정식을 고려한 아임계 영역의 동적 모사를 보고한다. 500MWe 급의 절탄기, 증발기와 과열기로 이루어진 단순한 보일러 시스템을 가정하였고, 증발기 모델링은 참고문헌 데이터와 검증을 진행 하였다. 이 시스템에 대하여 외란에 따른 정량적 응답특성을 살펴보았다. 또한, 수연비(증기량과 연료의 유량비)가 설계조건과 크게 다른 탈 설계 운전 사례에 대한 보일러 시스템의 동적 응답평가를 진행 하였다. 그 결과를 통해 적절한 수연비의 제어와 재순환 시스템과 분무 감온기 설계의 중요성이 재확인 되었다.