• 제목/요약/키워드: Attachment rate

검색결과 270건 처리시간 0.023초

후박추출물과 옥수수 불검화 추출물 혼합 경구용 제제가 비글견에서 실험적으로 유발된 치주염에 미치는 영향 (The effects of Magnoliae cortex and Zea Mays L. extract mixtures on experimentally induced periodontitis of beagle dog)

  • 김태일;정종평;구영
    • Journal of Periodontal and Implant Science
    • /
    • 제32권4호
    • /
    • pp.847-855
    • /
    • 2002
  • It has been reported that Magnoliae cortex extract has antibacterial and antimicrobial activity against pathogenic microbes and Zea Mays L. extract is effective for improving gingival tissue health. The purpose of this study was to examine the anti-inflammatory and antimicrobial effects of Zea Mays L. and Magnoliac cortex extract mixtures through experimental peridontitis induced beagle dog model. Nine beagle dogs with experimentally induced periodontitis were selected. Baseline clinical indices which includes plaque index, gingival index, probing pocket depth, clinical attachment level, gingival fluid flow rate were recorded and microbial assays were done. Magnoliac cortex and Zea Mays L., mixed at 2:l ratio in 105mg capsular dosage, were taken by 3 capsule (Group I) or 6 capsule dosages (Group II) three times a day. After 4,8,12 weeks, clinical indices were recorded. All data of clinical indices were compared through one-way ANOVA with 95% confidence level. Clinical indices of group I and II showed significantly better results than those of control group. There were no significant differences between group I and II. In conclusion, it was confirmed that mixture of Magnoliae cortex and Zea May L. (mix ratio 2:1) possessed clinical improving effects to periodontitis.

축류홴 익단누설와류의 수치적 해석 (Numerical Analysis of a Tip Leakage Vortex in an Axial Flow Fan)

  • 장춘만;김광용
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.36-44
    • /
    • 2004
  • Three-dimensional vortical flow and separated flow topology near the casing wall in an axial flow fan having two different tip clearances have been investigated by a Reynolds-averaged Navier-Stokes (RANS) flow simulation. The simulation shows that the tip leakage vortex formed close to the leading edge of the blade tip on suction side grows in the streamwise direction. On the casing wall, a separation line is formed upstream of the leakage vortex center due to the interference between the leakage vortex and main flow. The reverse flow is observed between the separation line and the attachment line generated downstream of the trailing edge, and increased with enlarging tip clearance. The patterns of a leakage velocity vector including a leakage flow rate are also analyzed according to two tip clearances. It is noted that the understanding of the distribution of a limiting streamline on the casing wall is very important to grasp the characteristics of the vortical flow in the axial flow fan.

Design and Implementation of a Latency Efficient Encoder for LTE Systems

  • Hwang, Soo-Yun;Kim, Dae-Ho;Jhang, Kyoung-Son
    • ETRI Journal
    • /
    • 제32권4호
    • /
    • pp.493-502
    • /
    • 2010
  • The operation time of an encoder is one of the critical implementation issues for satisfying the timing requirements of Long Term Evolution (LTE) systems because the encoder is based on binary operations. In this paper, we propose a design and implementation of a latency efficient encoder for LTE systems. By virtue of 8-bit parallel processing of the cyclic redundancy checking attachment, code block (CB) segmentation, and a parallel processor, we are able to construct engines for turbo codings and rate matchings of each CB in a parallel fashion. Experimental results illustrate that although the total area and clock period of the proposed scheme are 19% and 6% larger than those of a conventional method based on a serial scheme, respectively, our parallel structure decreases the latency by about 32% to 65% compared with a serial structure. In particular, our approach is more latency efficient when the encoder processes a number of CBs. In addition, we apply the proposed scheme to a real system based on LTE, so that the timing requirement for ACK/NACK transmission is met by employing the encoder based on the parallel structure.

다중 물 분사 노즐이 장착된 감온밸브의 해석 연구 (An Analysis Study on Desuperheater valve attachment on Multi Water Spray Nozzles)

  • 이덕구;조행훈;조남철;이채문
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2009
  • The generation of electric power and plant facilities have been attempting to improve energy efficiency with many efforts as those being basis of our country's economy. In particular, the CHP(Combined Heat Power plant) system, is producing the electricity and process steam, has generally been using for the cogeneration plants. When CHP system operates, the steam has to maintain the high temperature and high pressure in order to have high efficiency of electric power production as much as possible. In addition, the exhausted steam from the turbine has to reform proper temperature to use the needed process. The major purpose of desuperheater is that the superheated steam changes into the saturated steam because it is more efficient and suitable for using the process, furthermore, it is more convenient and stable regarding the process temperature control. The design of the desuperheater obtained through the experiment and preceding analysis. This paper is verified by analysis that water spray nozzle(${\Phi}$=28mm) shows the best ability under the real power plant condition.

  • PDF

Cavitation Surge Suppression of Pump Inducer with Axi-asymmetrical Inlet Plate

  • Kim, Jun-Ho;Ishzaka, Koichi;Watanabe, Satoshi;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권1호
    • /
    • pp.50-57
    • /
    • 2010
  • The attachment of inducer in front of main impeller is a powerful method to improve cavitation performance. Cavitation surge oscillation, however, often occurs at partial flow rate and extremely low suction pressure. As the cavitation surge oscillation with low frequency of about 10 Hz occurs in a close relation between the inlet backflow cavitation and the growth of blade cavity into the throat section of blade passage, one method of installing an axi-asymmetrical plate upstream of inducer has been proposed to suppress the oscillation. The inlet flow distortion due to the axi-asymmetrical plate makes different elongations of cavities on all blades, which prevent the flow from becoming simultaneously unstable at all throat sections. In the present study, changes of the suppression effects with the axial distance between the inducer inlet and the plate and the changes with the blockage ratios of plate area to the cross-sectional area of inducer inlet are investigated for helical inducers with tip blade angles of $8^{\circ}$ and $14^{\circ}$. Then a conceivable application will be proposed to suppress the cavitation surge oscillation by installing axi-asymmetrical inlet plate.

Biomechanical Test for Repair Technique of Full-thickness Rotator Cuff Tear

  • Lim, Chae-Ouk;Park, Kyoung-Jin
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.51-58
    • /
    • 2016
  • The arthroscopic rotator cuff repair is now considered a mainstream technique with highly satisfactory clinical results. However, concerns remain regarding healing failures for large and massive tears and high revision rate. In recent decades, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. The focus of biomechanical test in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. Recent studies have shown that a transosseous tunnel technique provides improved contact area and pressure between rotator cuff tendon and insertion footprint, and the technique of using double rows of suture anchors to recreate the native footprint attachment has been recently described. The transosseous equivalent suture bridge technique has the highest contact pressure and fixation force. In this review, the biomechanical tests about repair techniques of rotator cuff tear will be reviewed and discussed.

감마선 조사를 이용하여 Poly(ethylene glycol) Mathacrylate가 그래프팅된 케냐프 섬유를 포함하는 시멘트 복합재료의 제조 (Preparation of Cement Composites Containing Kenaf Fiber Has Been Gamma-ray Grafted with Poly(ethylene glycol) Methacrylate)

  • 이병민;강필현;전준표
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.49-52
    • /
    • 2014
  • Kenaf fibers have excellent properties and possess the potential to be outstanding reinforcing fillers in cement. The grafting of poly(ethylene glycol) methacrylate (PEGMA) to the kenaf fibers is important in improving the compatibility between the fibers and the cement. PEGMA was grafted onto kenaf fibers using gamma-ray radiation. The radiation dose ranged from 20 to 60 kGy, and the dose rate was $10kGy\;h^{-1}$. The degree of grafting increased with increased radiation doses. FT-IR analysis revealed an increase in PEGMA content after gamma-ray radiation induced grafting, further evincing the attachment of PEGMA to the kenaf fibers. The mechanical properties of the gamma-ray grafted kenaf fiber/cement composites were superior to those of the ungrafted kenaf fiber/cement specimens.

생체적 적용을 위한 전기전도성을 갖는 그래핀과 폴리카프로락톤 복합물질 전기방사 섬유형 필름 (Electroconductive Graphene-Combined Polycaprolactone Electrospun Films for Biological Applications)

  • 오준성;이은정
    • 한국재료학회지
    • /
    • 제31권5호
    • /
    • pp.278-285
    • /
    • 2021
  • This study produces electroconductive polycaprolactone (PCL)-based film with different amounts of graphene (G) through electrospinning, and the characteristics of the produced G/PCL composites are investigated. The G/PCL results are analyzed by comparing them with those obtained using pure PCL electrospun film as a control. The morphology of electrospun material is analyzed through scanning electron microscopy and transmission electron microscopy. Mechanical and electrical properties are also evaluated. Composites containing 1 % graphene have the highest elongation rate, and 5 % samples have the highest strength and elasticity. Graphene contents > 25 % show electro-conductivity, which level improves with increase of graphene content. Biological characteristics of G/PCL composites are assessed through behavioral analysis of neural cell attachment and proliferation. Cell experiments reveal that compositions < 50 % show slightly reduced cell viability. Moreover, graphene combinations facilitated cell proliferation compared to pure PCL. These results confirm that a 25 % G/PCL composition is best for application to systems that introduce external stimuli such as electric fields and electrodes to lead to synergistic efficiency of tissue regeneration.

Immobilization of Prussian blue nanoparticles in acrylic acid-surface functionalized poly(vinyl alcohol) sponges for cesium adsorption

  • Wi, Hyobin;Kang, Sung-Won;Hwang, Yuhoon
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.173-179
    • /
    • 2019
  • Prussian blue (PB) is known to be an effective material for radioactive cesium adsorption, but its nano-range size make it difficult to be applied for contaminated water remediation. In this study, a simple and versatile approach to immobilize PB in the supporting matrix via surface functionalization was investigated. The commercially available poly vinyl alcohol (PVA) sponge was functionalized by acrylic acid (AA) to change its major functional group from hydroxyl to carboxylic, which provides a stronger ionic bond with PB. The amount of AA added was optimized by evaluating the weight change rate and iron(III) ion adsorption test. The FTIR results revealed the surface functional group changing to a carboxyl group. The surface functionalization enhanced the attachment of PB, which minimized the leaching out of PB. The $Cs^+$ adsorption capacity significantly increased due to surface functionalization from 1.762 to 5.675 mg/g. These findings showed the excellent potential of the PB-PAA-PVA sponge as a cesium adsorbent as well as a versatile approach for various supporting materials containing the hydroxyl functional group.

Effects of the addition of low-dose ketamine to propofol anesthesia in the dental procedure for intellectually disabled patients

  • Hirayama, Akira;Fukuda, Ken-ichi;Koukita, Yoshihiko;Ichinohe, Tatsuya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권3호
    • /
    • pp.151-158
    • /
    • 2019
  • Background: This study aimed to examine whether the combination of low-dose ketamine and propofol in deep sedation is clinically useful in controlling the behavior in intellectually disabled patients who are typically extremely noncooperative during dental procedures. Methods: A total of 107 extremely noncooperative intellectually disabled adult patients were analyzed. In all patients, deep sedation was performed using either propofol alone (group P) or using a combination of propofol and 0.2 mg/kg or 0.4 mg/kg ketamine (groups PK0.2 and PK0.4, respectively). The procedures were performed in the order of insertion of nasal cannula into the nostril, attachment of mouth gag, and mouth cleaning and scaling. The frequency of patient movement during the procedures, mean arterial pressure, heart rate, peripheral oxygen saturation, recovery time, discharge time, and postoperative nausea and vomiting were examined. Results: The three groups were significantly different only in the frequency of patient movement upon stimulation during single intravenous injection of propofol and scaling. Conclusion: For propofol deep sedation, in contrast to intravenous injection of propofol alone, prior intravenous injection of low-dose ketamine (0.4 mg/kg) is clinically useful because it neither affects recovery, nor causes side effects and can suppress patient movement and vascular pain during procedures.