• Title/Summary/Keyword: Attaching

Search Result 942, Processing Time 0.024 seconds

Patterns of Mother-of-Pearl Craftwork Sketches and the Way of Supply and Demand of the Works in Modern and Contemporary Times (근·현대 나전도안과 공예품의 수급(需給)형태 - 중요무형문화재 제10호 나전장 송방웅 소장 나전도안을 중심으로 -)

  • Lee, Yeon Jae
    • Korean Journal of Heritage: History & Science
    • /
    • v.43 no.3
    • /
    • pp.334-365
    • /
    • 2010
  • Mother-of-Pearl craftwork sketch involves the whole process of making a piece of work. Therefore, it includes types, forms, sizes, and patterns of the work. Some information about when and by whom those works were manufactured and who ordered them are still found in some sketches. This paper seeks to find out popular types and patterns of the works in each period and its demand and the way of supply by examining the collection of approximately 1700 Mother-of-Pearl craftwork sketches from the period of Japanese colonization up to the present time, which are owned by Mr. Song Bang-wung, Important Intangible Cultural Heritage no.10. Typical patterns of sketches are the hua-jo(花鳥 : Flowers and Birds), the Sakunja(四君子 : Four Gracious Plants), cultural treasures, figures in folk tales, 'Su-bok(壽福)' characters, and landscape. The pattern sketches have changed according to the circumstances of Korean society. During the period of Japanese colonization from the 1920s to the 1940s the manufacture and the supply and demand of Mother-of-Pearl craftworks were controled by the Japanese government. As a result, many of the patterns were adjusted to the Japanese taste. Most of its customers were also Japanese. During the 1950s after Independence the American Military Forces appeared as new customers due to the Korean War. Thus, the traditional Korean patterns to decorate accessories adored by American soldiers gained popularity. Foreign Mother-of-Perls were imported from the late 1960s to the 1970s. They were bigger and more colorful than those of Korean and it enabled the sketches bigger and the patterns more various. The most popular pattern in this period was the pattern of cultural treasures, such as an image of Buddha, metalcraft works, porcelains and pagodas. In terms of a technique, new techniques, such as engraving and rusting were introduced. There was a great demand for Mother-of-Pearl craftworks in the 1970s as people were highly interested in them. They were entirely made to order and there was a large demand from diverse organizations, furniture dealers and individuals. And the Mother-of-Pearl craftwork was in full flourish in the 1970s due to the country's economic development and the growth of national income. Mass production of the works was possible and the professional designers who drew patterns actively worked in this period. The favor of Mother-of-Pearl craftworks declined in the 1980s since the built-in furniture and the Western style of furniture became prevalent due to the change of housing into apartments. But it seemed that the manufacture of Mother-of-Pearl craftworks revived for once the technique of Kunum-jil(끊음질 : cutting and attaching) became popular in Tong-young(統營). After the 1990s, however, the making of Mother-of-Pearl craftworks gradually declined as the need of them decreased. Now it barely maintains its existence by a few artisans.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Prediction of Entrance Surface Dose in Chest Digital Radiography (흉부 디지털촬영에서 입사표면선량 예측)

  • Lee, Won-Jeong;Jeong, Sun-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.573-579
    • /
    • 2019
  • The purpose of this study is predicted easily the entrance surface dose (ESD) in chest digital radiography. We used two detector type such as flat-panel detector (FP) and IP (Imaging plate detector). ESD was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image. Dose-area product (DAP) or exposure index (EI) was checked by Digital Imaging and Communications in Medicine (DICOM) header on phantom images. Statistical analysis was performed by the linear regression using SPSS ver. 19.0. ESD was significant difference between FP and IP($85.7{\mu}Gy$ vs. $124.6{\mu}Gy$, p=0.017). ESD was positively correlated with image quality in FP as well as IP. In FP, adjusted R square was 0.978 (97.8%) and linear regression model was $ESD=0.407+68.810{\times}DAP$. DAP was 4.781 by calculating the $DAP=0.021+0.014{\times}340{\mu}Gy$. In IP, adjusted R square was 0.645 (64.5%) and linear regression model was $ESD=-63.339+0.188{\times}EI$. EI was 1748.97 by calculating the $EI=565.431+3.481{\times}340{\mu}Gy$. In chest digital radiography, the ESD can be easily predicted by the DICOM header information.

Verification of Multi-point Displacement Response Measurement Algorithm Using Image Processing Technique (영상처리기법을 이용한 다중 변위응답 측정 알고리즘의 검증)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.3A
    • /
    • pp.297-307
    • /
    • 2010
  • Recently, maintenance engineering and technology for civil and building structures have begun to draw big attention and actually the number of structures that need to be evaluate on structural safety due to deterioration and performance degradation of structures are rapidly increasing. When stiffness is decreased because of deterioration of structures and member cracks, dynamic characteristics of structures would be changed. And it is important that the damaged areas and extent of the damage are correctly evaluated by analyzing dynamic characteristics from the actual behavior of a structure. In general, typical measurement instruments used for structure monitoring are dynamic instruments. Existing dynamic instruments are not easy to obtain reliable data when the cable connecting measurement sensors and device is long, and have uneconomical for 1 to 1 connection process between each sensor and instrument. Therefore, a method without attaching sensors to measure vibration at a long range is required. The representative applicable non-contact methods to measure the vibration of structures are laser doppler effect, a method using GPS, and image processing technique. The method using laser doppler effect shows relatively high accuracy but uneconomical while the method using GPS requires expensive equipment, and has its signal's own error and limited speed of sampling rate. But the method using image signal is simple and economical, and is proper to get vibration of inaccessible structures and dynamic characteristics. Image signals of camera instead of sensors had been recently used by many researchers. But the existing method, which records a point of a target attached on a structure and then measures vibration using image processing technique, could have relatively the limited objects of measurement. Therefore, this study conducted shaking table test and field load test to verify the validity of the method that can measure multi-point displacement responses of structures using image processing technique.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Development for Fishing Gear and Method of the Non-Float Midwater Pair Trawl Net (III) - Opening Efficiency of the Model Net attaching the Kite - (무부자 쌍끌이 중층망 어구어법의 개발 (III) - 카이트를 부착한 모형어구의 전개성능 -)

  • 유제범;이주희;이춘우;권병국;김정문
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.197-210
    • /
    • 2003
  • The non-float midwater pair trawl was effective in the mouth opening and control of the working depth in midwater and bottom. In contrast, we confirmed that it was difficult to keep the net at surface above 30 m of the depth by means of the full scale experiment in the field and the model test in the circulation water channel. To solve this problem, the kites were attached to the head rope of the non-float midwater pair trawl. In this study, four kinds of the model experiments were carried out with the purpose of applying the kite to the korean midwater pair trawl. The results obtained can be summarized as follows: 1. The working depth of the non-float midwater pair trawl with the kite was shallower than that of the proto type and non-float type. The working depth of the kite type was approximately 20m with 2 kites and about 5m with 4 kites under 4.0 knot. The working depth was almost constant but the depth of the head rope sank approximately 15m and 10m according to the increase in the front weight and the wing-end weight, respectively. The changing aspect of the working depth was constant, but the depth of the head rope sank approximately 22m according to the increase in the lower warp length (dL). 2. The hydrodynamic resistance of the kite type was almost increased in a linear form in accordance with the flow speed increase from 2.0 to 5.0 knot. The increasing grate of the hydrodynamic resistance tended to increase in accordance with the increase in flow speed. The hydrodynamic resistance of the kite type was larger approximately 5~10 ton larger than that of the non-float type and the proto type. The hydrodynamic resistance of the kite type increased approximately 3ton with the changing of the front weight from 1.40 to 3.50 ton and approximately 4 ton with the changing of the wing-end weight from 0 to 1.11 ton and approximately 5.5 ton with the changing lower warp length (dL) from 0 to 40 m, respectively. 3. The net height of the kite type was increased approximately 10 m with the change in the kite area from $2,270mm^2$ to 4,540 $\textrm{mm}^2$. The net height of the kite type was aproximately 50 m and 30 m larger than that of the proto type and the non-float type, respectively. The changed aspect of the net width was approximately 5m with the variation of the flow speed from 2.0 to 5.0 knot. 4. The filtering volume of the kite type was larger than that of the proto type and the non-float type by 28%, 34% at 2.0 knot of the flow speed and 42%, 41% at 3.0 knot, and 62%, 45% at 4.0 knot, and 74%, 54% at 5.0knot, respectively. The optimal towing speed was approximately 3.0 knot for the proto type and was over 4.0 knot for the non-float type, and the optimal towing speed reached 5.0 knot for the kite type. 5. The opening efficiency of the kite type was approximately 50% and 25% larger than that of the proto type and the non-float type, respectively.

A STUDY ON THE TEMPERATURE CHANGES OF BONE TISSUES DURING IMPLANT SITE PREPARATION (임플랜트 식립부위 형성시 골조직의 온도변화에 관한 연구)

  • Kim Pyung-Il;Kim Yung-Soo;Jang Kyung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.1-17
    • /
    • 2002
  • The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice of $Br{\aa}nemark$ implant system. All the burs for $Br{\aa}nemark$ implant system were studied except the round bur The experiments involved 880 drilling cases : 50 cases for each of the 5 steps of NP, 5 steps of RP, and 7 steps of WP, all including srew tap, and 30 cases of 2mm twist drill. For precision drilling, a precision handpiece restraining system was developed (Eungyong Machinery Co., Korea). The system kept the drill parallel to the drilling path and allowed horizontal adjustment of the drill with as little as $1{\mu}m$ increment. The thermocouple insertion hole. that is 0.9mm in diameter and 8mm in depth, was prepared 0.2mm away from the tapping bur the last drilling step. The temperatures due to countersink, pilot drill, and other drills were measured at the surface of the bone, at the depths of 4mm and 8mm respectively. Countersink drilling temperature was measured by attaching the tip of a thermocouple at the rim of the countersink. To assure temperature measurement at the desired depths, 'bent-thermocouples' with their tips of 4 and 8mm bent at $120^{\circ}$ were used. The profiles of temperature variation were recorded continuously at one second interval using a thermometer with memory function (Fluke Co. U.S.A.) and 0.7mm thermocouples (Omega Co., U.S.A.). To simulate typical clinical conditions, 35mm square samples of bovine scapular bone were utilized. The samples were approximately 20mm thick with the cortical thickness on the drilling side ranging from 1 to 2mm. A sample was placed in a container of saline solution so that its lower half is submerged into the solution and the upper half exposed to the room air, which averaged $24.9^{\circ}C$. The temperature of the saline solution was maintained at $36.5^{\circ}C$ using an electric heater (J. O Tech Co., Korea). This experimental condition was similar to that of a patient s opened mouth. The study revealed that a 2mm twist drill required greatest attention. As a guide drill, a twist drill is required to bore through a 'virgin bone,' rather than merely enlarging an already drilled hole as is the case with other drills. This typically generates greater amount of heat. Furthermore, one tends to apply a greater pressure to overcome drilling difficulty, thus producing even greater amount heat. 150 experiments were conducted for 2mm twist drill. For 140 cases, drill pressure of 750g was sufficient, and 10 cases required additional 500 or 100g of drilling pressure. In case of the former. 3 of the 140 cases produced the temperature greater than $47^{\circ}C$, the threshold temperature of degeneration of bone tissue (1983. Eriksson et al.) which is also the reference temperature in this study. In each of the 10 cases requiring extra pressure, the temperature exceeded the reference temperature. More significantly, a surge of heat was observed in each of these cases This observations led to addtional 20 drilling experiments on dense bones. For 10 of these cases, the pressure of 1,250g was applied. For the other 10, 1.750g were applied. In each of these cases, it was also observed that the temperature rose abruptly far above the thresh old temperature of $47^{\circ}C$, sometimes even to 70 or $80^{\circ}C$. It was also observed that the increased drilling pressure influenced the shortening of drilling time more than the rise of drilling temperature. This suggests the desirability of clinically reconsidering application of extra pressures to prevent possible injury to bone tissues. An analysis of these two extra pressure groups of 1,250g and 1,750g revealed that the t-statistics for reduced amount of drilling time due to extra pressure and increased peak temperature due to the same were 10.80 and 2.08 respectively suggesting that drilling time was more influenced than temperature. All the subsequent drillings after the drilling with a 2mm twist drill did not produce excessive heat, i.e. the heat generation is at the same or below the body temperature level. Some of screw tap, pilot, and countersink showed negative correlation coefficients between the generated heat and the drilling time. indicating the more the drilling time, the lower the temperature. The study also revealed that the drilling time was increased as a function of frequency of the use of the drill. Under the drilling pressure of 750g, it was revealed that the drilling time for an old twist drill that has already drilled 40 times was 4.5 times longer than a new drill The measurement was taken for the first 10 drillings of a new drill and 10 drillings of an old drill that has already been used for 40 drillings. 'Test Statistics' of small samples t-test was 3.49, confirming that the used twist drills require longer drilling time than new ones. On the other hand, it was revealed that there was no significant difference in drilling temperature between the new drill and the old twist drill. Finally, the following conclusions were reached from this study : 1 Used drilling bur causes almost no change in drilling temperature but increase in drilling time through 50 drillings under the manufacturer-recommended cooling conditions and the drilling pressure of 750g. 2. The heat that is generated through drilling mattered only in the case of 2mm twist drills, the first drill to be used in bone drilling process for all the other drills there is no significant problem. 3. If the drilling pressure is increased when a 2mm twist drill reaches a dense bone, the temperature rises abruptly even under the manufacturer-recommended cooling conditions. 4. Drilling heat was the highest at the final moment of the drilling process.

NFC-based Smartwork Service Model Design (NFC 기반의 스마트워크 서비스 모델 설계)

  • Park, Arum;Kang, Min Su;Jun, Jungho;Lee, Kyoung Jun
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.2
    • /
    • pp.157-175
    • /
    • 2013
  • Since Korean government announced 'Smartwork promotion strategy' in 2010, Korean firms and government organizations have started to adopt smartwork. However, the smartwork has been implemented only in a few of large enterprises and government organizations rather than SMEs (small and medium enterprises). In USA, both Yahoo! and Best Buy have stopped their flexible work because of its reported low productivity and job loafing problems. In addition, according to the literature on smartwork, we could draw obstacles of smartwork adoption and categorize them into the three types: institutional, organizational, and technological. The first category of smartwork adoption obstacles, institutional, include the difficulties of smartwork performance evaluation metrics, the lack of readiness of organizational processes, limitation of smartwork types and models, lack of employee participation in smartwork adoption procedure, high cost of building smartwork system, and insufficiency of government support. The second category, organizational, includes limitation of the organization hierarchy, wrong perception of employees and employers, a difficulty in close collaboration, low productivity with remote coworkers, insufficient understanding on remote working, and lack of training about smartwork. The third category, technological, obstacles include security concern of mobile work, lack of specialized solution, and lack of adoption and operation know-how. To overcome the current problems of smartwork in reality and the reported obstacles in literature, we suggest a novel smartwork service model based on NFC(Near Field Communication). This paper suggests NFC-based Smartwork Service Model composed of NFC-based Smartworker networking service and NFC-based Smartwork space management service. NFC-based smartworker networking service is comprised of NFC-based communication/SNS service and NFC-based recruiting/job seeking service. NFC-based communication/SNS Service Model supplements the key shortcomings that existing smartwork service model has. By connecting to existing legacy system of a company through NFC tags and systems, the low productivity and the difficulty of collaboration and attendance management can be overcome since managers can get work processing information, work time information and work space information of employees and employees can do real-time communication with coworkers and get location information of coworkers. Shortly, this service model has features such as affordable system cost, provision of location-based information, and possibility of knowledge accumulation. NFC-based recruiting/job-seeking service provides new value by linking NFC tag service and sharing economy sites. This service model has features such as easiness of service attachment and removal, efficient space-based work provision, easy search of location-based recruiting/job-seeking information, and system flexibility. This service model combines advantages of sharing economy sites with the advantages of NFC. By cooperation with sharing economy sites, the model can provide recruiters with human resource who finds not only long-term works but also short-term works. Additionally, SMEs (Small Medium-sized Enterprises) can easily find job seeker by attaching NFC tags to any spaces at which human resource with qualification may be located. In short, this service model helps efficient human resource distribution by providing location of job hunters and job applicants. NFC-based smartwork space management service can promote smartwork by linking NFC tags attached to the work space and existing smartwork system. This service has features such as low cost, provision of indoor and outdoor location information, and customized service. In particular, this model can help small company adopt smartwork system because it is light-weight system and cost-effective compared to existing smartwork system. This paper proposes the scenarios of the service models, the roles and incentives of the participants, and the comparative analysis. The superiority of NFC-based smartwork service model is shown by comparing and analyzing the new service models and the existing service models. The service model can expand scope of enterprises and organizations that adopt smartwork and expand the scope of employees that take advantages of smartwork.

Variation of Genus Ilex in Korea and their Ornamental Values (Ilex속(屬) 수목(樹木)의 유전변이(遺傳變異)의 분석(分析)과 조경학적(造景學的) 이용가치(利用價値)의 조사(調査) 연구(硏究))

  • Yim, Kyong Bin
    • Journal of Korean Society of Forest Science
    • /
    • v.42 no.1
    • /
    • pp.1-38
    • /
    • 1979
  • The woody species of Genus Ilex which are endemic to Korea are distributed on limited area due to solely temperature factor. There is some differences according to species, however in general, the evergreen Ilex are found along southern coastal area of Korean Peninsula and near islands where the cold index does not exceed $-5^{\circ}C$. But Ilex macropoda and the variety, only deciduous ones, are grown in temperate zone of the peninsula and some islands. The list of Ilex species of Korea are as follows. Ilex cornuta Lindley et Pax., I. crenata Thunb. var. microphylla Max., I. crenata Thunb., I. rotunda Thunb., I. macropoda Miq., I. macropoda Miq. var. pseudo-macropoda Loensner, I. integra Thunb. The author surveyed the populations of Ilex species as many as possible and data of some characters such as leaf shape, spine, fruit shape, stomata density, sex ratio in natural communities, etc. are collected. Almost all the Ilex species in Korea show sporadic distribution. This means quite small sized populations isolate distantly each other eliminating the change of gene exchange in between. Particularly Ilex conuta and I. crenata show the morphological differentiation among populations as well as significant individual variation within a population. These were true with such characteristics, leaf shape, leaf dimension, leaf margin, fruit shape, spine, and stomata density. The founded are that the fruit length and the stomata density counted on the beneath surface of leaves of Ilex cornuta increased with the decrease of latitude. These are naturally closely related with the cold index values. The table shown below indicates the correlation between mean stomata density per $0.3642mm^2$ and cold index values. These relation however were not observed on Ilex crenata. The most dominated natured in relation to individual variation were outline of leaf, the number of marginal spine, the shape of leaf cross section and the degree of luster of the upper leaf surface. As shown in photos 5~7, these variations are agreed at a glance. There are reports that the development of marginal spines in some Ilex species is associated with the juvenility and topophysis. In present study, these two factors were neglected because of the intended sampling procedure. Of Ilex rotunda, population difference with the characteristics of leaf length is recognized but not for leaf width, petiole length, and fruit size. However, individual variations within a population were significantly large. In case of Ilex integra, only individual differences within population were calculated statistically for such characteristics as leaf length, leaf width, and petiole length. As to natural population, the sex ratio was 1:2 (female to male) for Ilex cornuta, and 1:1 for Ilex crenata. The tendency of more male than female in I. cornuta was agreed to other observations. Preparing the tip cutting of length 10cm, and treating with IBA, then attaching earth ball to the cut end, very successful rooting percentages were obtained. Asexual propagation has the advantages of maintaining the heterozygosity of existing varieties and overcoming the difficulties of delayed seed germination frequently encountered with Ilex species. Considering a great deal of variation in morphological traits, a good possibility of selection breeding for decorative and ornamental purposes exists. At present, these evergreen Ilex are ignored by local people as nuisance weedy shrubs. So the proper protection measures should promptly be taken.

  • PDF