• 제목/요약/키워드: Atomic absorption analysis

검색결과 274건 처리시간 0.029초

EPR Investigation on a Quantitative Analysis of Eu(II) and Eu(III) in LiCl/KCl Eutectic Molten Salt

  • Park, Yong-Joon;Kim, Tack-Jin;Cho, Young-Hwan;Jung, Yong-Ju;Im, Hee-Jung;Song, Kyu-Seok;Jee, Kwang-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권1호
    • /
    • pp.127-129
    • /
    • 2008
  • EPR spectroscopic technique was applied for a quantitative analysis of Eu(II) for a speciation of europium in a LiCl-KCl eutectic melt. By adopting the first absorption line of each isotopes (151Eu and 153Eu), a calibration plot was obtained. The calibration of the EPR intensity shows a good linearity according to the amount of Eu(II). The EPR intensity was identified to increase proportionally with a decrease of the attenuation parameter for EPR microwave power. The fluorescence technique was used qualitatively to find whether either of Eu(II) or Eu(III) ions exists in a molten salt sample. The ICP-AES technique was also adopted to determine the total concentration of europium in the sample, since EPR is only sensitive for detecting the Eu(II) ion. The extent of the reduction of Eu(III) in the LiCl-KCl eutectic melt at 723 K was determined by using this technique.

Hydride Generation Atomic Absorption Spectrometry를 이용한 석유정제폐수중의 selenium 분석 (Analysis of selenium in oil refinery wastewater by hydride generation atomic absorption spectrometry)

  • 천미희;김철;이현주;강임석
    • 분석과학
    • /
    • 제16권5호
    • /
    • pp.399-406
    • /
    • 2003
  • 본 연구는 수소화물 발생장치가 부착된 원자흡광 광도계 (HG-AAS)를 이용하여 비교적 고농도의 Se을 함유하고 있는 석유정제 폐수의 Se 분석을 위하여 적합한 분석조건을 선정하고자 수행되었다. Se(VI)의 Se(IV)로의 환원 실험에서 폐수량 10 mL, 염산 주입량 10 mL, 가열시간 30분이 최적 환원조건으로 결정되었다. 폐수의 조성성분과 유기물의 농도가 높은 경우에는 Se 회수율이 감소하였다. 따라서 3가지 산분해법 ($HNO_3/HClO_4$ 분해, $KMnO_4$ 분해 및 초단파 산분해)에 의한 유기물, 석유화합물 분해 및 유기성 Se(org.), Se(IV) 산화에 따른 Se 회수율을 검토하였다. 실험결과 산분해전 약 50~80%이었던 Se 회수율은 모든 산분해에서 90%이상이었으며 특히, 초단파 산분해에 의한 Se 회수율이 가장 높은 것으로 나타났다. 그러므로 HG-AAS를 이용한 석유정제 폐수의 Se 분석시에는 초단파 산분해후 염산 처리를 하는 전처리 과정이 가장 적합한 것으로 나타났다.

용매추출법에 의한 토양중의 미량 구리와 아연원소의 동시추출 및 정량에 관한 연구 (The Simultaneous Extraction and Determination of Trace Copper and Zinc in Solvent Extraction)

  • 정창웅;지석주;박종안
    • 한국환경보건학회지
    • /
    • 제21권3호
    • /
    • pp.87-95
    • /
    • 1995
  • A rapid and selective co-extraction systems of copper and zinc-thiocyanate complex into various types of alkylamine for the simultaneous determination of two metal ions by atomic absorption spectrometry and ion chromatograph have been proposed. The quantitative extractions of Cu(II) and Zn(II) at 0.1 M-thiocyanate and 0.1 M-HCI were achieved with Aliquat 336-$CHCl_3$. The detection limits of Cu and Zn were 2 ppb and 0.9 ppb respectively.

  • PDF

시판 웅담의 미량금속 정량에 관한 연구 (Determination of Trace Metals in Fel Ursi)

  • 이숙연;유봉신;문혜령;김성경
    • 생약학회지
    • /
    • 제13권3호
    • /
    • pp.102-105
    • /
    • 1982
  • Nine trace elements in Bear Galls(Fel Ursi) studied in this paper are Na, Mg, K, Ca, Cu, Zn, Fe, Pb and Ge. The contents of Na, Mg, K, Ca, Cu, Zn, Fe, Pb are determined by atomic absorption spectrometry and Ge is determined by graphite atomic absorption spectrometry. In both methods, the sample is digested with nitric-perchloric acid and then ashed. The results of analysis are shown in table and the result obtained from this study are as follows. a. The highest content of trace element of Bear Gall is Na and other elements are getting lower in order of K, Mg, Ca, Ge, Zn, Fe, Cu, and Pb. b. Particularly the content of Ge in Bear Gall was determined.

  • PDF

Determination Of Dissolved Trace Metals In Sea Water By Atomic Absorption Spectrophotometry After Concentration By Fe (III) - APDC Coprecipitation

  • Lee, Dong-Soo;Lee, Soo-Hyung;Kwak, Hi-Sang;Lee, Kwang Woo
    • 한국해양학회지
    • /
    • 제15권1호
    • /
    • pp.66-70
    • /
    • 1980
  • A method for the determination of dissolved species of Cd, Co, Cu, Ni, Pb and Zn in sea water by flame atomic absorption spectrophotometry (AAS) is described. Prior to analysis by AAS, these elements are concentrated by coprecipitation with iron pyrrolidinedithiocarbamate at pH 3 because of matrix effects and their low concentration levels in sea water. The detection limits are 0.01, 0.04, 0.02, 0.05, 0.08, and 0.03$\mu\textrm{g}$/l, and the relative standard deviations are 1.0, 2.4, 1.3, 2.9, 2.0 and 2.9% for Cd, Co, Cu, Ni, Pb and Zn, respectively. The method is shown to be satisfactory in terms of recovery and precision for the determination of these metals in sea water.

  • PDF

Absorption and Fluorescence Spectra of Dy(Ⅲ) Complexes with Some Terdentate Ligands

  • 정승희
    • Bulletin of the Korean Chemical Society
    • /
    • 제13권6호
    • /
    • pp.650-654
    • /
    • 1992
  • Absorption and fluorescence spectra are reported for four different 1 : 3 $Dy^{3+}$ : ligand systems in aqueous solution under mild alkaline pH conditions. The ligands included in this study are oxidiacetate, dipicolinate, iminodiacetate and methyliminodiacetate. The oscillator strengths for the 4f→4f multiplet-to-multiplet transitions are empirically determined from the absorption spectra and the intensity parameters ${\Omega}_{\lambda}$}(${\lambda}$ = 2, 4, 6) for the systems are also obtained by applying the Judd-Ofelt theorem to the observed oscillator strengths. The values of the intensity parameters for the systems are compared and discussed in terms of ligand structural properties to investigate how the intensity parameters can response to the minor changes in the ligand environment. In addition, the relative oscillator strengths for fluorescence are evaluated and compared to the results obtained from absorption spectra.

다이오드 레이저 흡수분광법을 이용한 산소 동위원소의 성분비 측정 (Measurement of oxygen isotope ratio using tunable diode laser absorption spectroscopy)

  • 박상언;정도영;김재우;고광훈;임권;정의창;김철중
    • 한국광학회지
    • /
    • 제15권1호
    • /
    • pp.1-5
    • /
    • 2004
  • 분리막을 이용한 산소-18 분리실험에서 분리된 시료의 동위원소 성분비 분석을 위해 다이오드 레이저 흡수분광장치를 구성하였다. 흡수신호의 신호 대 잡음비를 높이기 위해 lock-in증폭기를 사용한 파장변조 분광법을 채택하였다. 레이저의 주파수 변조폭 최적화와 FFT 저역통과 필터링을 통해 다중반사흡수셀에서 발생하는 간섭무늬 잡음을 줄였다. 산소-18에 대한 흡수분광장치의 최대편차는 $\pm$4$\textperthousand$로 측정되었다.

전자선 가교된 PBT의 충격 특성 및 내마모 특성 연구 (The Impact Properties and Wear Resistance of Polybutylene terephthalate (PBT) Cross-linked by Electron Beam Irradiation)

  • 신범식;고금진;전준표;김현빈;오승환;강필현
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.145-149
    • /
    • 2011
  • Poly(butylenes terephthalate) have made large strides in applications of injection, extrusion, and molding material due to their excellent thermal resistance and appropriate mechanical properties. However, PBT was not hard polymer but a soft polymer which caused low absorption of external energy and the defect of being easily broken with the strong impact. Thus, the electron beam irradiation was carried out over a range of irradiation doses from 100 to 1,000 kGy for enhancing the properties. The decreases of $T_m$, $T_c$, and enthalpy were observed as increasing the absorbed dose in the results of DSC analysis. The improvement in the impact strength of PBT was clearly observed as the absorbed dose was increased. This was probably due to the 3-dimensional network structures, resulting in increasing the absorption of impact energy. In addition, the wear properties had increased at higher than 300 kGy. The negative deviation of weight loss confirmed the improvement of the wear properties of PBT, as evidenced by SEM observation on the wear surfaces.

THE BIDAS-2007: BIOASSAY DATA ANALYSIS SOFTWARE FOR EVALUATING A RADIONUCLIDE INTAKE AND DOSE

  • Lee, Jong-Il;Lee, Tae-Young;Kim, Bong-Whan;Kim, Jang-Lyul
    • Nuclear Engineering and Technology
    • /
    • 제42권1호
    • /
    • pp.109-114
    • /
    • 2010
  • Bioassay data analysis software (BiDAS-2007) has been developed by KAERI, which adds several new functions to its previous version. New functions of the BiDAS-2007 computer code enable the user not only to do a simultaneous analysis by using two or more types of bioassay for the best internal dose evaluation, but also to do a continual internal dose evaluation from a change of the internal exposure conditions such as an intake type (acute, chronic), an intake pathway (inhalation, ingestion), an absorption type (Type F, M, S), and a particle size (AMAD, activity median aerodynamic diameter), and also to estimate the intakes in various conditions of an internal exposure at a time. The values calculated by the BiDAS-2007 code are consistent and in good agreement with those values by IMIE-2004 code by Berkovski and IMBA code by Birchall. The BiDAS-2007 computer code is very useful and user-friendly to estimate the radionuclide intakes and committed effective doses of a radiation worker.

방사능 분석에서 밀도에 따른 HPGe 검출기의 검출효율 변화 (Variation of the Detection Efficiency of a HPGe Detector with the Density of the Sample in the Radioactivity Analysis)

  • 서범경;이길용;윤윤열;정기정;오원진;이근우
    • 분석과학
    • /
    • 제18권1호
    • /
    • pp.59-65
    • /
    • 2005
  • 방사능 준위가 낮은 시료의 경우에는 방사능 측정 시 많은 양의 시료가 요구되며, 시료량의 증가로 인하여 방출된 감마선이 시료 자체에서 산란되거나 흡수될 확률이 증가하게 되므로 검출기에 도달할 확률은 감소하게 된다. 이러한 자체흡수효과를 보정하기 위해서는 측정시료의 기하학적 조건 및 밀도에 따른 효율을 보정하여야 한다. 대부분의 측정에서 기하학적인 조건은 표준선원과 동일한 측정용기를 사용함으로서 해결될 수 있다. 그러나 다양한 종류의 폐기물을 측정대상으로 할 경우에는 측정시료와 동일한 기하학적 조건 및 밀도를 가지는 표준선원을 이용하여 효율을 결정한다는 것은 사실상 불가능하다. 다양한 측정 용기에 대하여 측정 시료의 밀도 차이에 따른 자체흡수효과를 비교하기 위하여 수용액 상태의 표준선원에 용해도가 높고 밀도가 큰 NaI를 첨가하면서 밀도차이에 따른 검출기의 효율 변화를 조사하였다. 모든 결과는 Monte Carlo 방법에 의한 계산결과와 비교하였으며, 500 keV 이하의 낮은 에너지 영역에서는 자체흡수효과에 대한 보정이 이루어지지 않을 경우 많은 오차가 발생한다는 것으로 확인하였다.