• Title/Summary/Keyword: Atmospheric pressure ionization

Search Result 42, Processing Time 0.022 seconds

Experimental Study for the Identification of the Nascent Product of OH Heterogeneous Reaction with NaCl using Chemical Ionization Mass Spectrometry

  • Park, Jong-Ho;Ivanov, Andrey V.;Molina, Mario J.
    • Mass Spectrometry Letters
    • /
    • v.3 no.4
    • /
    • pp.108-111
    • /
    • 2012
  • An experimental study on the nascent product of the OH heterogeneous reaction with NaCl was performed under dry and wet conditions using a bead-filled flow tube system coupled to a high-pressure chemical ionization mass spectrometer. The ozone concentration in the flow tube for the atomic hydrogen removal was varied in order to control the conversion reaction of molecular chlorine into HCl for the identification of the nascent product. The mass spectrometric observation was that the $O_3$ introduction reduced the concentration HCl, while it increased the concentration of $Cl_2$ and ClO. Based on the experimental results, we suggest that the nascent product of the titled reaction is gaseous $Cl_2$, which is followed by fast conversion into HCl in presence of H. No significant difference in the concentration profile between under dry and wet (RH = 2%) conditions was observed.

Moisture Induced Hump Characteristics of Shallow Trench-Isolated nMOSFET (Shallow Trench Isolation 공정에서 수분에 의한 nMOSFET의 Hump 특성)

  • Lee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.12
    • /
    • pp.2258-2263
    • /
    • 2006
  • In this parer, hump characteristics of short-channel nMOSFETs induced by moistures of the ILD(inter-layer dielectric) layer in the shallow trench isolation (STI) process are investigated and the method for hump suppression is proposed Using nMOSFETs with various types of the gate and a measurement of TDS-APIMS (Thermal Desorption System-Atmospheric Pressure ionization Mass Spectrometry), hump characteristics were systematically analyzed and the systemic analysis based hump model was presented; the ILD layer over poly-Si gate of nMOSFET generates moistures, but they can't diffuse out of the SiN layer due to the upper SiN layer. Consequently, they diffuses into the edge between the gate and STI and induces short-channel hump. In order to eliminate moisture in the ILD layer by out-gassing method, the annealing process prior to the deposition of the SiN layer was carried out. As the result, short-channel humps of the nMOSFETs were successfully suppressed.

Identification of triacylglycerols in coix seed extract by preparative thin layer chromatography and liquid chromatography atmospheric pressure chemical ionization tandem mass spectrometry

  • Sim, Hee-Jung;Lee, Seul gi;Park, Na-Hyun;Kim, Youna;Cho, Hyun-Woo;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.102-111
    • /
    • 2017
  • Here we reported a methodology for identification of triacylglycerols (TAGs) and diacylglycerols (DAGs) in coix seed by preparative thin layer chromatography (prep-TLC) and non-aqueous reversed-phase liquid chromatography (NARP LC)-atmospheric pressure chemical ionization (APCI) tandem mass spectrometry (MS/MS). Lipid components were extracted from coix seed by reflux extraction using n-hexane for 3 hr. TAGs and DAGs in coix seed extract were effectively purified and isolated from matrix interferences by prep-TLC and then analyzed by LC-APCI-MS and MS/MS for identification. TAGs were effectively identified taking into consideration of their LC retention behavior, APCI-MS spectra patterns, and MS/MS spectra of $[DAG]^+$ ions. In MS/MS spectra of TAGs, diacylglycerol-like fragment $[DAG]^+$ ions were useful to identify TAGs with isobaric fragment ions. Based on an established method, 27 TAGs and 8 DAGs were identified in coix seed extract. Among them, 15 TAGs and 8 DAGs were for the first time observed in coix seed. Interestingly, some of TAGs isolated by prep-TLC were partly converted into DAGs through probably photolysis process during storing in room temperature. Thus, degradation phenomenon of TAGs should be considered in the quality evaluation and nutritional property of coix seed. LC-APCI-MS/MS combined with prep-TLC will be practical method for precise TAG and DAG analysis of other herbal plants.

Micro-gap DBD Plasma and Its Applications

  • Zhang, Zhitao;Liu, Cheng;Bai, Mindi;Yang, Bo;Mao, Chengqi
    • Journal of the Speleological Society of Korea
    • /
    • no.76
    • /
    • pp.37-42
    • /
    • 2006
  • The Dielectric Barrier Discharge (DBD) is a nonequilibrium gas discharge that is generated in the space between two electrodes, which are separated by an insulating dielectric layer. The dielectric layer can be put on either of the two electrodes or be inserted in the space between two electrodes. If an AC or pulse high voltage is applied to the electrodes that is operated at applied frequency from 50Hz to several MHz and applied voltages from a few to a few tens of kilovolts rms, the breakdown can occur in working gas, resulting in large numbers of micro-discharges across the gap, the gas discharge is the so called DBD. Compared with most other means for nonequilibrium discharges, the main advantage of the DBD is that active species for chemical reaction can be produced at low temperature and atmospheric pressure without the vacuum set up, it also presents many unique physical and chemical process including light, heat, sound and electricity. This has led to a number of important applications such as ozone synthesizing, UV lamp house, CO2 lasers, et al. In recent years, due to its potential applications in plasma chemistry, semiconductor etching, pollution control, nanometer material and large area flat plasma display panels, DBD has received intensive attention from many researchers and is becoming a hot topic in the field of non-thermal plasma.

Observation of Discharge Mode Transient from Townsend to Glow at Breakdown of Helium Atmospheric Pressure Dielectric Barrier Discharge (헬륨 대기압 유전체 격벽 방전기의 타운젠트-글로우 방전 모드 전이 연구)

  • Bae, Byeongjun;Kim, Nam-Kyun;Yoon, Sung-Young;Shin, Jun-Seop;Kim, Gon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.26-31
    • /
    • 2016
  • The Townsend to glow discharge mode transition was investigated in the dielectric barrier discharge (DBD) helium plasma source which was powered by 20 kHz / $4.5 kV_{rms}$ high voltage at atmospheric pressure. The spatial profile of the electric field strength at each modes was measured by using the intensity ratio method of two helium emission lines (667.8 nm ($3^1D{\rightarrow}2^1P$) and 728.1 nm ($3^1S{\rightarrow}2^1P$)) and the Stark effect. ICCD images were analyzed with consideration for the electric field property. The Townsend discharge (TD) mode at the initial stage of breakdown has the light emission region located in the vicinity of the anode. The electric field of the light emitting region is close to the applied field in the system. Immediately, the light emitting region moves to the cathode and the discharge transits to the glow discharge (GD) mode. This mode transition can be understood with the ionization wave propagation. The electric field of the emitting region of GD near cathode is higher than that of TD near anode because of the cathode fall formation. This observation may apply to designing a DBD process system and to analysis of the process treatment results.

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Pulsed ionization Chamber Technique for Measurement of Recombination Rate of Plasmas

  • Kim, Sang-Hoon
    • Nuclear Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.253-259
    • /
    • 1974
  • The output signal voltage of the pulsed ionization chamber (PIC) was measured for a range of electron density (10$^{13}$ -10$^{17}$ m$^{-3}$ ) of the 3He plasmas. This experimental data was in excellent agreement with the theory including space charge effects. As an application of the PIC techniques, two-body recombination coefficients were obtained with electron densities measured from output signal voltage of the PIC. These values as a function of pressure were in good agreement with theoretical predictions and ranged from 5$\times$10$^{-14}$ to 3$\times$10$^{-13}$ (㎥/sec) at 300$^{\circ}$K for 1 to 10 atmospheric $^3$He plasma.

  • PDF

Preliminary Tests on the Characteristics of Free Jet Flow with Applying Electric Fields (교류 전기장이 인가된 층류 자유제트유동의 특성에 관한 예비 조사)

  • Kim, Gyeong Taek;Lee, Won June;Park, Jeong;Kwon, Oh Boong
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.191-194
    • /
    • 2014
  • The characteristics of laminar free jet flow with having applied AC electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that the jet flow with AC was modified significantly. At a certain axial distance, the laminar fuel stem was broken down and subsequently it was separated into three parts when AC electric fields were applied over a certain voltage in a range of frequencies less than 120 Hz. The breakdown point was measured by varying applied AC voltage and frequency. The effect of applying electric fields to jet flow was discussed in detail.

  • PDF

Preliminary Tests on Change of Free Jet Flow in Laminar with Applying Electric Fields (교류 전기장이 인가된 층류 자유제트유동의 변화에 관한 예비 조사)

  • Kim, Gyeong Taek;Lee, Won June;Park, Jeong
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.383-386
    • /
    • 2014
  • The characteristics of gas free jet flows in laminar with having applied electric fields have been investigated experimentally. A single electrode configuration was adopted such that electric fields were applied directly to nozzle and thus the surrounding could be an infinite ground. The experimental results showed that breakdown point at laminar flow has been measured by varying the applied voltage and frequency of AC. The effect of applying electric fields to free jet flow in laminar was discussed in detail.

  • PDF

Simple and Direct Quantitative Analysis for Quinidine Drug in Fish Tissues

  • Chen, Yuan-Chin;Abdelhamid, Hani Nasser;Wu, Hui-Fen
    • Mass Spectrometry Letters
    • /
    • v.8 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • Analysis of quinidine for fish tissues using single drop microextraction (SDME) coupled with atmospheric pressure matrix assisted laser desorption/ionization mass spectrometry (AP-MALDI-MS) are reported. Optimization conditions; such as extraction solvent, extraction time, pH of the aqueous solution, salt additions (NaCl), stirring rate, matrix type and concentration are investigated. Linear dynamic range (${\mu}M$), limit of detection, relative recovery%, and enrichment factor are 0.08-9.2, 0.05, $94.8{\pm}3.1-98.5{\pm}3.3%$, $4.34{\pm}0.28-4.40{\pm}0.30$, respectively. SDME-AP-MALDI-MS shows good intraday and interday reproducibility.