• 제목/요약/키워드: Atmosphere gases

검색결과 272건 처리시간 0.027초

The Exchange of Reduced Sulfur Gases Across the Atmosphere-Teerrestrial Biosphere Interface

  • Kim, Ki-Hyun;Zhen Yand;Shiming Wang
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제12권E호
    • /
    • pp.1-18
    • /
    • 1996
  • In this review, the significance of terrestrial ecosystems in the global sulfur budget has been reviewed based on the currently available databases covering the topic. In the section 1, we describe our current understanding of natural sulfur cycle in relation to most well-known natural reservoir, oceanic environment. The sections 2 and 3 provide the fundamental pictures of the rerrestrial sulfur cycle with respect to the relative importance of its individe the fundamental pictures of the terrestrial sulfur cycle with respect to the section 3, previously reported flux values for several major sulfur gases are presented for each reservoir and are intercompared to derive representative fluxes for the respective environment. In the section 4, source mechanisms for volatile sulfur species are dealt for both microscale and macroscale processes leading to their productions. In the section 5, environmental factors controlling the exchange of biogenic sulfur gases across the air-surface have been discussed. In the section 6, environmental fate of sulfur gases released into the atmosphere has been described. Finally in tie section 7, as concluding remarksm we discuss directions and suggestions to overcome various limitations encountered from previous measurement investigations of natural sulfur cycle in diverse natural ecological systems.

  • PDF

한반도 배경대기 중 온실기체의 농도 변동 특성 분석 (Analysis of Variation Characteristics of Greenhouse Gases in the Background Atmosphere Measured at Gosan, Jeju)

  • 주옥정;차준석;이동원;김영미;이정영;박일수
    • 한국대기환경학회지
    • /
    • 제23권4호
    • /
    • pp.487-497
    • /
    • 2007
  • Increase of the greenhouse gases emissions during last century has led remarkable changes in our environment and climate system. Continuous monitoring of atmospheric constituents over the world is positively necessary to understand these changes around us. The concentrations of greenhouse gases ($CO_2,\;CH_4,\;N_2O,\;CFCs$) have been continuously measured at Global Climate Change Monitoring station in Gosan, Jeju since January, 2002. In this study, the variation characteristics of greenhouse gases as well as their annual, seasonal and diurnal trend using the data from January, 2002 to December, 2005 were analyzed. The raw data which was used in the analysis were validated with the methods recommended by WDCGG (World Data Center for Greenhouse Gases). The concentration of $CO_2$ was increasing continuously by 2.1 ppm/year, while $CH_4$ did not show any increasing or decreasing trend clearly for 4 years. The concentration of $N_2O$ was slightly increasing and CFCs were decreasing except CFC-12 which has longer lifetime compared with other CFCs. The variations of the greenhouse gases at Gosan were shown to be consistent with the global trend. But the concentration level of $CO_2$ in Korea was more or less higher than abroad.

Characteristics of dissolved gases separated from water mixed with exhalation gases without using a compressor

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권10호
    • /
    • pp.916-921
    • /
    • 2016
  • It is possible for humans to breathe underwater using dissolved oxygen. However, unlike fish, humans need large amounts of oxygen to breathe underwater. Water generally contains small amounts of dissolved oxygen. To get enough dissolved oxygen from water, great volumes of it should be supplied into a separation device. If exhalation gases are used, the amounts of water supplied into the membrane can be decreased. However, the characteristics of exhalation gases after passage through the separation device need to be investigated. To reuse the exhalation gases, the concentration of carbon dioxide should be decreased. A compressor is needed to supply the exhalation gases because of the high pressure generated in the membrane inlet. However, compressors require a lot of power and are heavy, so it is not proper to get the portable separation device. A system without the compressor is needed. If the pressure of the position mixed from the exhalation is less than atmosphere, the compressor is not needed. In this thesis, characteristics of the gases which are mixed with exhalation gases and separated from water after passing the membrane are investigated. The compositions of carbon dioxide, oxygen, and nitrogen are measured with the gas chromatography. The effects of water and exhalation gas flow rates on characteristics of gases separated from water after the membrane are showed.

날숨이 혼합된 물을 사용한 압축기없는 용존기체 분리기의 분리 특성 (Separation characteristics of separation devices using inlet water mixed with exhalation gases without a compressor)

  • 허필우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.842-846
    • /
    • 2016
  • 물속의 용존산소를 이용하면 물고기가 아가미를 이용하여 호흡하듯이 사람이 수중에서 호흡이 가능하지만, 물속에 포함된 용존산소의 양이 적기 때문에 필요한 산소량을 확보하는 문제가 해결되어야 한다. 우선 물의 유량을 증가시켜 분리되는 산소량을 증가하는 것이 가능하지만, 필요한 펌프와 멤브레인 그리고 주변기기의 용량 증가로 분리장치의 부피와 무게 그리고 소요비용도 함께 증가하게 된다. 이러한 문제를 효과적으로 해결하기 위해 많은 양의 산소를 포함하는 날숨의 특성을 이용하면 필요한 산소량을 효과적으로 확보할 수 있다. 일반적으로 날숨에 포함된 산소량은 공기보다 낮고, 이산화탄소 량은 공기보다 많은 것으로 알려져 있다. 본 연구에서는 용존기체 분리장치의 입력 단에 날숨을 혼합한 후, 용존기체 분리장치에서 산소를 포함하는 용존기체를 재분리하는 과정을 거치며, 이때, 입력단에 설치된 수중펌프의 동작으로 수압이 증가하므로, 이러한 수압을 갖는 물에 날숨을 혼합하기 위해서는 압축기가 요구되므로 분리장치의 무게와 부피 그리고 소비 전력이 증가하게 된다. 본 연구에서는 입력단의 압력을 감소시킴으로써 압축기를 사용하지 않고도 날숨을 물에 혼합하는 구조를 갖는 것이 특징이다. 실험을 통해 압축기를 사용하지 않고 날숨이 입력단의 물에 혼합되는 것이 가능함을 제시하였으며, 날숨이 입력단에 공급된 후 분리장치를 통해 분리된 기체의 분리특성을 제시하였다. 날숨을 사용함으로써 용존기체의 분리량이 크게 증가하였으며, 공급되는 날숨의 유량이 증가하면 분리되는 용존 기체의 양도 증가하였다.

$MoO_3$ 박막센서 제조 및 가스감지특성 (Fabrication and Gas Sensing Characteristics of $MoO_3$ Thin Film Sensor)

  • 황종택;장건익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.826-829
    • /
    • 2002
  • $MoO_3$ thin films were deposited on electrode and heater screen-printed alumina substrates in en atmosphere by RF reactive sputtering. The deposition was performed at $300^{\circ}C$ with 350W of a forward power in an $Ar-O_2$ atmosphere. The working pressure was maintained at $3{\times}10^{-2}$mtorr and all deposited films were annealed at $500^{\circ}C$ for 5hours. The surface morphology of films was observed by using a SEM and crystalline phases were analyzed by XRD. The sensing properties were investigated in term of gas concentration under exposure of reducing gases such as $H_2$, $NH_3$ and CO.

  • PDF

THE EXTRACTION OF THE THERMAL RADIATION ASSOCIATED WITH GREENHOUSE GASES FROM AIRS MEASUREMENTS

  • Kwon, Eun-Han;Kim, Yong-Seung;Lee, Sun-Gu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.301-304
    • /
    • 2006
  • For the purpose of investigating the contributions of various gases to climate change, the thermal radiation associated with greenhouse gases are extracted from AIRS (Atmospheric Infrared Sounder) infrared radiances over the tropical pacific region. AIRS instrument which was launched on the EOS-Aqua satellite in May 2002 covers the spectral range from 650 cm-1 to 2700 cm-1 with a spectral resolution of between 0.4 cm-1 and 1 cm-1. In order to extract the thermal radiation absorbed by individual gases, the interfering background radiances at the top of the atmosphere are simulated using the radiative transfer code MODTRAN (MODerate spectral resolution atmospheric TRANsmittance). The simulations incorporated the temperature and water vapor profiles taken from NCEP (National Centers for Environmental Prediction) reanalyses. The differences between the simulated background radiance and AIRS-measured radiance result in the absorption of upward longwave radiation by atmospheric gases (i.e. greenhouse effect). The extracted absorption bands of individual gases will allow us to quantify the radiative forcing of individual greenhouse gases and thus those data will be useful for climate change studies and for the validation of radiative transfer codes used in general circulation models.

  • PDF

청정에너지 회수용 유증기/매연 포집모듈에 관한 연구 (A Study on the Oil-mist/Smoke Collecting Module for the Pure Energy Recycling)

  • 김명수;오꾸라 시게노부;함경춘
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.279-284
    • /
    • 2009
  • Traditionally, so-called "industrial waste gases", such ad exhaust from boilers at industrial installations and a large quantity of soot discharged from power station, before their release into the atmosphere, have been on occasion subjected to an air cleaning process to remove fine particles that may pollute the atmosphere (such as mist and dust containing various powdery or oily substances and moisture from industrial waste gases). The release of industrial waste gases containing these particles directly into the atmosphere poses a serious threat to the earth environment; and recovery of these noxious substances is required by law in some countries and local governments. in urban areas, air pollution from automobile exhaust and others creates a serious condition. Some homes are equipped with and use indoor air purifiers. In many of the kitchens of restaurants, smoke generated during cooking and otherwise contaminated air are cleansed by air purifiers before being released outside or recycled inside. For the dust collecting devices to recover the fine particles contained in contaminated air, the cause for air pollution and how to purify air, many types based on various principles are known. Specifically, classified based on theories of particle collection, filtration, gravity, inertia, centrifugation, electricity, and cleaning types are cited as available processes. Among them, an appropriate type is selected according to the size or type of fine particles to be collected and conditions for installation. For the efficiency of dust collection, a filtration system (by using bag filters and others) and electric system are particularly outstanding and are therefore used widely in various areas of industry. In this research, rotary type high performance oil mist and smoke collecting system with self auto cleaning device equipped with the cleaning fluid spraying section is investigated.

  • PDF

Low-Oxygen Atmosphere and its Predictors among Agricultural Shallow Wells in Northern Thailand

  • Wuthichotwanichgij, Gobchok;Geater, Alan F.
    • Safety and Health at Work
    • /
    • 제6권1호
    • /
    • pp.18-24
    • /
    • 2015
  • Background: In 2006, three farmers died at the bottom of an agricultural shallow well where the atmosphere contained only 6% oxygen. This study aimed to document the variability of levels of oxygen and selected hazardous gases in the atmosphere of wells, and to identify ambient conditions associated with the low-oxygen situation. Methods: A cross-sectional survey, conducted in June 2007 and July 2007, measured the levels of oxygen, carbon monoxide, hydrogen sulfide, and explosive gas (percentage of lower explosive limit) at different depths of the atmosphere inside 253 wells in Kamphaengphet and Phitsanulok provinces. Ambient conditions and well use by farmers were recorded. Carbon dioxide was measured in a subset of wells. Variables independently associated with low-oxygen condition (<19.5%) were identified using multivariate logistic regression. Results: One in five agricultural shallow wells had a low-oxygen status, with oxygen concentration decreasing with increasing depth within the well. The deepest-depth oxygen reading ranged from 0.0% to 20.9%. Low levels of other hazardous gases were detected in a small number of wells. The low-oxygen status was independently associated with the depth of the atmosphere column to the water surface [odds ratio (OR) = 13.5 for 8-11 m vs. <6 m], depth of water (OR = 0.17 for 3-<8 m vs. 0-1 m), well cover (OR = 3.95), time elapsed since the last rainfall (OR = 7.44 for >2 days vs. <1 day), and location of well in sandy soil (OR = 3.72). Among 11 wells tested, carbon dioxide was detected in high concentration (>25,000 ppm) in seven wells with a low oxygen level. Conclusion: Oxygen concentrations in the wells vary widely even within a small area and decrease with increasing depth.

팽이버섯의 선도유지를 위한 환경기체조절포장 (Modified Atmosphere Packaging for Keeping Freshness of Enoki Mushroom(Flammulina velutipes))

  • 조숙현;이동선;이상대;김낙구;류재산
    • 한국식품영양과학회지
    • /
    • 제27권6호
    • /
    • pp.1137-1142
    • /
    • 1998
  • Modified atmosphere packagings were designed by combining the respiration characteristics of the enoki mushroom at 10oC and the measured film permeabilities to O2 and CO2 gases to attain the beneficial package atmosphere were fabricated and tested during storage. The packages of 100g size with 30 m low density polyethylene and cast polypropylene showed the good agreement between estimated and experimental package atmospheres. However, polyvinylchloride stretch wrap packs showed the gas composition close to the air, which was due to leaking of stretch wrapping. The CPP package attaining O2 below 1% and CO2 concentration of 15~20% gave the best retention of quality and thus the longest shelf life among the tried packages, and it was superior to the others in the Hunter L value, stipe elongation and sensory qualties.

  • PDF

혼합가스 분위기 중에서 공업용 순 타이타늄의 고온산화 거동 (High-Temperature Oxidation Behavior of Commercial Pure Titanium in Mixed Gases)

  • 박성호;안용식
    • 동력기계공학회지
    • /
    • 제11권2호
    • /
    • pp.44-50
    • /
    • 2007
  • The oxidation behavior of commercial pure titanium is investigated in the temperature range of $727^{\circ}C{\sim}950^{\circ}C$ in mixed gases. The weight change is measured by TGA during oxidation in mixed gases. The oxidation behavior indicated by weight gain or the growth of oxide layer is based on the linear rate law at high temperatures. The structure of the oxide scale formed during oxidation is analysed by optical microscopy, electron probe microanalyzer, scanning electron microscope and x-ray diffraction. Oxide scales have a $TiO_2$ structure, and are constituted with multi-layered or two layered porous external one and a dense internal one. Ti-O solid solution region is formed at the interface of metal and scale layer. The formation of oxide scale is influenced by the oxidation temperature, time, crystal structure and the condition of atmosphere.

  • PDF