• Title/Summary/Keyword: Asymmetrical control

Search Result 139, Processing Time 0.029 seconds

Noise Control of Hard Disk Drive Using Structural Mobility Analysis (STRUCTURAL MOBILITY 분석을 통한 하드 디스크 드라이브의 소음제어(현장개발사례: SAMSUNG HDD 'SPINPOINT V20/P20 SERIES' ))

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Oh, Dong-Ho;Pham, Tho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.911-916
    • /
    • 2001
  • Structural acoustic modification method based on the structural mobility analysis is applied to reduce the structure-borne noise radiated from hard disk drive system. Sound intensity techniques and ODS(Operational Deflection Shape) techniques are also used in order to provide the structural acoustic information for the mobility modification. The sound intensity is for the acoustic visualization of the noise source locations, and the ODS is for the visualization of the vibration pattern and its dynamic characteristics of the noise sources. Using visualization information of sound and vibration, local structural input mobility is reduced in the frequency band of interest by designing asymmetrical wave-stringer structure in the wave-number domain as well as frequency domain. The overall sound pressure level is reduced by 4dB and its controlled sound power radiated from the disk drive is proved to under 2.8Bel in idle-spinning mode and 3.1 Bel in random-seeking mode, which are the lowest noise levels in the hard disk drive industry.

  • PDF

A Modified Switched-Diode Topology for Cascaded Multilevel Inverters

  • Karasani, Raghavendra Reddy;Borghate, Vijay B.;Meshram, Prafullachandra M.;Suryawanshi, H.M.
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1706-1715
    • /
    • 2016
  • In this paper, a single phase modified switched-diode topology for both symmetrical and asymmetrical cascaded multilevel inverters is presented. It consists of a Modified Switched-Diode Unit (MSDU) and a Twin Source Two Switch Unit (TSTSU) to produce distinct positive voltage levels according to the operating modes. An additional H-bridge synthesizes a voltage waveform, where the voltage levels of either polarity have less Total Harmonic Distortion (THD). Higher-level inverters can be built by cascading MSDUs. A comparative analysis is done with other topologies. The proposed topology results in reductions in the number of power switches, losses, installation area, voltage stress and converter cost. The Nearest Level Control (NLC) technique is employed to generate the gating signals for the power switches. To verify the performance of the proposed structure, simulation results are carried out by a PSIM under both steady state and dynamic conditions. Experimental results are presented to validate the simulation results.

Design and Implementation of a Single Input Fuzzy Logic Controller for Boost Converters

  • Salam, Zainal;Taeed, Fazel;Ayob, Shahrin Md.
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.542-550
    • /
    • 2011
  • This paper describes the design and hardware implementation of a Single Input Fuzzy Logic Controller (SIFLC) to regulate the output voltage of a boost power converter. The proposed controller is derived from the signed distance method, which reduces a multi-input conventional Fuzzy Logic Controller (CFLC) to a single input FLC. This allows the rule table to be approximated to a one-dimensional piecewise linear control surface. A MATLAB simulation demonstrated that the performance of a boost converter is identical when subjected to the SIFLC or a CFLC. However, the SIFLC requires nearly an order of magnitude less time to execute its algorithm. Therefore the former can replace the latter with no significant degradation in performance. To validate the feasibility of the SIFLC, a 50W boost converter prototype is built. The SIFLC algorithm is implemented using an Altera FPGA. It was found that the SIFLC with asymmetrical membership functions exhibits an excellent response to load and input reference changes.

Analysis, Design and Implementation of a Soft Switching DC/DC Converter

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.20-30
    • /
    • 2013
  • This paper presents a soft switching DC/DC converter for high voltage application. The interleaved pulse-width modulation (PWM) scheme is used to reduce the ripple current at the output capacitor and the size of output inductors. Two converter cells are connected in series at the high voltage side to reduce the voltage stresses of the active switches. Thus, the voltage stress of each switch is clamped at one half of the input voltage. On the other hand, the output sides of two converter cells are connected in parallel to achieve the load current sharing and reduce the current stress of output inductors. In each converter cell, a half-bridge converter with the asymmetrical PWM scheme is adopted to control power switches and to regulate the output voltage at a desired voltage level. Based on the resonant behavior by the output capacitance of power switches and the transformer leakage inductance, active switches can be turned on at zero voltage switching (ZVS) during the transition interval. Thus, the switching losses of power MOSFETs are reduced. The current doubler rectifier is used at the secondary side to partially cancel ripple current. Therefore, the root-mean-square (rms) current at output capacitor is reduced. The proposed converter can be applied for high input voltage applications such as a three-phase 380V utility system. Finally, experiments based on a laboratory prototype with 960W (24V/40A) rated power are provided to demonstrate the performance of proposed converter.

The Commanding Amigo and Its Spirit Embodiment: An Inquiry into the Relationship between Manobo-Visayan Compadrazgo Social Relationship in the "Modern" Manobo Cosmology and Ritual

  • Buenconsejo, Jose S.
    • SUVANNABHUMI
    • /
    • v.6 no.1
    • /
    • pp.161-191
    • /
    • 2014
  • The entry of the logging industry in the once heavily forested riverine middle Agusan Valley where aboriginal Manobos live meant the entry of the material practice of wage labor into this out-of-the-way place. Wage labor converted the once relatively isolated, subsistence animist Manobos into laborers of the expanding capitalist regime. A symptom of modernity, this wage labor also accompanied the coming of Visayan settlers (also loggers paid by wage) who introduced indigenous Manobos the compadrazgo social relationship. This friendly relationship across ethnic identities legitimated social ties and is a social material practice represented in recent bilingual Manobo possession rituals where the Visayan spirit is incarnated along with Manobo spirits. To understand the idea behind spirit embodiment, I explore Manobo ritual as mimesis or poeisis. This representation is shaped by concrete material realities as much as these realities, in turn, are reconfigured by ritual practice. In the older Manobo cosmology, which is based on subsistence economy and dependent on the forest and rivers, individuals have an externalized self (as manifest in the idea of twin soul), in which the inner vital principle is co-extensive with a spirit double in cosmos. Manobos imitate the perceived workings of nature in ritual so as to control them in times of illnesses. In contrast, the mimesis of the Visayan spirit is based on a different political economic set up with its attendant asymmetrical interpersonal relationship. By symbolically representing the Visayan patron as friend, Manobos are able to negotiate the predicament of their subalternity in local modernity.

  • PDF

Three-Dimensional Video Analysis of the Gate Patterns in Normal Children and Hemiplegic Children with Cerebral Palsy (정상아와 편마비 뇌성마비아의 삼차원 보행분석)

  • Lee Jin-Hee;Bae Sung-Soo;Kim Chung-Sun
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.127-145
    • /
    • 1997
  • The purpose of this study wa9 to analyse the gait patterns of two female children with hemiplegic cerebral palsy by using the three-dimensional video motion analysis technique. Case 1 has mild spastic hemiplegia on the right side while Case 3 has moderate spastic hemiplegia on the left side. A group of 10, normal female children of the same age(7-8 years old) were selected as the control group for comparison. Time and distance variables as well as the Center of Mass displacement, and the pelvic and joint motions in three anatomical planes were analysed for this purpose. The following observations were made through the analysis : Case 1 revealed an asymmetrical gait pattern in which the step length of the unaffected side was shorter than that of the affected side, which wan a result of the effort to minimize loading on the affected leg by shortening the swing phase of the unaffected leg. Case 1 scored similar phase ratios, cadence and walking velocity to the normal group. A slight posterior tilt of the pelvis was observed throughout the gait cycle. Less hip and knee flexion than the normal group was observed, and demonstrated hyperextension of the knee in the terminal stance phase. The main problem in case 1 originated from the insufficient dorsiflexion of the affected foot during the swing phase. Therefore, Case 1 has difficulty with foot clearance in the swing phase. Usually, this is compensated for by using exessive hip abduction and medial rotation in conjuction with trunk elevation as well as increased vortical displacement of the center of mass. Case 1 revealed a foot-flat initial contact pattern. Case 2 was characterized by a consistent retraction ef the affected aide of the body througout the gait cycle, As a result, an asymmetrical gait pattern with increased stance phase ratios of the unaffected side was observed. In spite of this the step lengths of both sieds were similar. Case 2 scored lower cadence and walking speed than the normal group with lower gait stability. The main problem in Case 2 originated from an excessive plantaflexion of the affected foot which, in turn, rebutted in high hip and knee flexion. Hyperextension of the knee was observed at mid-stance, and execessive anterior tilt of the pelvis throughout the gait cycle was noticed. A gait pattern with high hip abduction and medial circumduction was maintained for the stability in the stance phase and foot clearance in the swing phase. Case 2 revealed a forefoot-contact initial contact pattern.

  • PDF

Origin and Characteristics of Sand Ridges in the western Continental Shelf of Korean Peninsula (한반도 서부대륙붕에 발달한 사퇴의 발생기원과 특성)

  • 방효기;이차원
    • 한국해양학회지
    • /
    • v.29 no.3
    • /
    • pp.217-227
    • /
    • 1994
  • From northeast to southwest, discontinuous sand ridges distribute on the western continental shelf of Korean Peninsular. The dimension of sand ridges is 3 to 21 m high, 3.1 to 6.8 km wavelength and 9-64 km long with 0.5 steep slope. they are probably originated and reformed by the intensity of tidal current according to the sea level rise. The characteristics of sand ridges revealed in study area are summarized as follows: (1) The sand ridges line up with the long axes of the tidal current ellipses, indicating a tidal control. (2) these are composed of two sedimentary sequences on the 3.5 kHz seismic profiles and core sediments. The upper sequence characterized by prolonged type is covered with thin veneer of massive fine sand(Mz, 2-3$\phi$) with Olive Gray(5Y 5/2). The lower sequence is characterized by internal reflector type with parallel and discontinuous. It consists of sandy mud or muddy sand(Mz, 5-7$\phi$) with laminar structures. the parallel internal reflectors are truncated on the slope of sand ridges. (3) Asymmetrical sand waves are superimposed on the sand ridges, and facing to the crest. However, symmetrical sand waves lie on the crest. Sand ridges having characteristics above is originated by scouring of tidal current, covered with coarase relict sediments, and modified by sadware.

  • PDF

A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters (2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

Design of Supersonic Wind Tunnel for Analysis of Flow over a Backward Facing Step with Slot Injection (슬롯 분사가 있는 후향계단 유동장 분석을 위한 초음속풍동 설계)

  • Kim, Ick-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.363-367
    • /
    • 2016
  • A test section of a supersonic wind tunnel was designed for the analysis of flow characteristics over a backward-facing step with Mach 1.0 slot injection in a supersonic flow of Mach 2.5. The cavity flow of a high-speed vehicle is very complex at supersonic speed, so it is necessary to do experiments using supersonic wind tunnels to verify numerical analysis methods. The previous 2D symmetrical nozzle was replaced with an asymmetrical nozzle. The inviscid nozzle contour was designed using Method of Characteristics (MOC), and the boundary layer thickness correction was reflected by experimental data from the wind tunnel. The results were compared with a CFD analysis. The PID control system was changed to be based on the change of tank pressure. This improved the control efficiency, and the run times of supersonic flow increased by about 1 second. The flow characteristics over a backward facing step with slot injection were visualized by a Schlieren device. This equipment will be used for an experimental study of the film cooling effectiveness over a cavity with various velocities, mass flows, and temperatures.

Problem Analysis and Recommendations for Using Manual Wheelchair for One-hand Users

  • Park, Gemus;Hwang, Jung Bo;Jung, Hwa Shik
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.109-124
    • /
    • 2014
  • Objective: This study was conducted for one-hand users including hemiplegic clients currently using general folding manual wheelchairs, so as to analyze their specific problems and recommend solutions regarding usage. Background: Traditional manual wheelchairs require considerable use and control of both hands for operation, thus adaptations become necessary for individuals with asymmetrical use of hands. Method: Thirty hemiplegic clients who were admitted to rehabilitation and convalescent hospitals participated as subjects. The research tools were general folding manual wheelchairs commonly used by people with impaired gait, and the Wheelchair Skills Tests (WST) WST-M/WCU 4.1 version was adopted as the assessment tool. All participants were asked to fill out questionnaires on demographics and wheelchair usage characteristics. Assessment procedures were performed with currently used manual wheelchairs and with/without the use of foot to control the wheelchair. Results: When the participants drove folding manual wheelchairs without the use of foot, even the lowest failure rate among the WST items tested recorded 96.7%. On the contrary, with the use of foot in maneuvering the wheelchairs, failure rates dropped noticeably and success rate among the WST items tested was as high as 86.7%. Conclusion: These findings imply that the use of one-arm (hand) propellable (drivable) wheelchair can be an active and effective solution in resolving problems for hemiplegic clients using existing manual wheelchairs. As such, the government should provide institutional support to further develop and distribute this device or technology, and promote relative research in tandem. For now, the supply of commercially available device to hemiplegic clients is deemed urgent and also a mechanism to provide the devices and relevant services. Application: This study offers viable solutions for hemiplegic clients who rely on existing manual wheelchairs to increase their mobility and occupational performance.