• 제목/요약/키워드: Asymmetrical control

검색결과 139건 처리시간 0.019초

조선시대 측4량가 건축의 구조와 특징 (A study on the Structure and Design Concept of Asymmetrical Building with 4 Purlins in the Joseon Dynasty)

  • 김버들;이종서
    • 건축역사연구
    • /
    • 제28권6호
    • /
    • pp.7-18
    • /
    • 2019
  • This study is to find out the design concept of asymmetrical building with 4 purlins mainly in Sungkyunkwan(Confucian Shrines), Changgyeonggung palace and Changdeokgung palace The results are as follows: First, asymmetrical building with 4 purlins has the same height pillars, which was useful to control the side lenght and put a higher pillar without limit. Second, the side length of the asymmetrical building with 4 purlins is between 12 to 14 Ja[尺]. It's relatively longer than the minimum length(12 Ja) of 5 purlins architecture seen in later Joseon dynasty. Third, asymmetrical building with 4 purlins was not an anomalous structure when compared to 3 purlins and 5 purlins. It was actually a traditional style, unlike the current architectural recognition nowadays, which mainly focused on the balanced roof structure. These examples show that the architectures in Early Joseon dynasty were planned and constructed first according to the plane division that fit in a specific use or space.

Full Bridge Resonant Inverter Using Asymmetrical Control with Resonant-frequency Tracking for Ultrasonic Cleaning Applications

  • Jittakort, Jirapong;Sangswang, Anawach;Naetiladdanon, Sumate;Koompai, Chayant;Chudjuarjeen, Saichol
    • Journal of Power Electronics
    • /
    • 제17권5호
    • /
    • pp.1150-1159
    • /
    • 2017
  • Flexibility in the power control of ultrasonic transducers has remained a challenge for cleaning applications. This paper introduces a modification of the existing piezoelectric ceramic transducer (PCT) circuit to increase the range of operation through its impedance characteristics. The output power is controlled using the asymmetrical voltage-cancellation (AVC) method. Together with a phase-locked loop control, the switching frequency of the inverter is automatically adjusted to maintain a lagging phase angle under load-parameter variations during the cleaning process. With the proposed modification, the region of the zero-voltage switching (ZVS) operation is extended, which results in a wider range of output power control. A hardware prototype is constructed and the control algorithm is implemented using an STM32F4 microcontroller. Simulation and experimental results are provided to verify the proposed method for a 50-W PCT. The operating frequency and output power ranges under study are 37 - 41 kHz and 15.8 - 50 W, respectively.

비대칭형 PWM 교류쵸퍼의 기본파 전압제어 및 고조파 전압제거 (Asymmetrical PWM Technique with Fundamental Voltage Control and Harmonic Voltage Elimnation in AC Choppers)

  • 장도현;최규하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1067-1070
    • /
    • 1992
  • Optimal Asymmetrical Pulse-width Modulated (APWM) technique for ac chopper is proposed which can improve the input power factor and eliminate the harmonics of output voltage up to a specified order, and also enables linear control of the fundamental component of the output voltage. The PWM switching patterns at the specified phase angle are obtained by Newton-Raphson method and theoretical comparisons are made with other PWM and APWM technique.

  • PDF

전하 제어 비대칭 하프 브리지 직류-직류 컨버터의 소신호 모델링과 페루프 특성 해석 (Small-Signal Modeling and Closed-Loop Analysis of Charge Control Employed to Asymmetrical Half-Bridge Dc-to-Dc Converter)

  • 임원석;차헌녕;최병조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1151-1153
    • /
    • 2004
  • In this paper, small-signal modeling and closed-loop performance of charge control employed to an asymmetrical half-bridge (ASHB) dc-to-dc converters are investigated. The charge control is selected as an alternative to the conventional voltage-mode control and peak current-mode (PCM) control, which have their respective limitations and problems when adapted to ASHB dc-to-dc converters. The current-loop dynamics of the charge control are presented in comparison with those of voltage-mode and PCM control. This paper demonstrates that the charge control offers better dynamic performance compared to voltage-mode control and superior noise characteristics compared to PCM control. The potential problem of charge control are also addressed.

  • PDF

Control and Modulation of Three to Asymmetrical Six-Phase Matrix Converters based on Space Vectors

  • Al-Hitmi, Mohammed A.;Rahman, Khaliqur;Iqbal, Atif;Al-Emadi, Nasser
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.475-486
    • /
    • 2019
  • This paper proposes the modulation and control of a three-to-six-phase matrix converter with an asymmetrical six-phase output. The matrix converter (MC) outputs consist of two sets of three-phase spatially shifted by $30^0$, where the two sets have two isolated neutrals. The space vector approach is considered for the modeling and subsequent modulation of the three-to-six phase MC. The intelligent selection of voltage space vectors is made to synthesize the reference voltages and to obtain a sinusoidal output. The dwell times of selected voltage space vectors are adjusted in such a way that the effect of the second and the third auxiliary plane vectors (i.e., x1-y1, and x2-y2) are nullified. To achieve the maximum output voltage gain and to ensure that no reactive power is drawn from the utility supply, the input side power factor is maintained at unity. Nevertheless, the source side power factor is controllable. The modulation technique is implemented in dSPACE working in conjunction with a FPGA. Hardware results that validate the proposed control algorithm are discussed.

The Effects of Repetitive Sit-to-Stand Training with a Paretic-side Asymmetrical Foot Position on the Balance of Chronic Stroke Subjects

  • Park, Jae Hyo;Kim, Young Mi;Lee, Na Kyung
    • The Journal of Korean Physical Therapy
    • /
    • 제27권3호
    • /
    • pp.169-173
    • /
    • 2015
  • Purpose: This study aimed to improve the asymmetrical weight-bearing ratio, by applying different repetitive sit-to-stand training methods to the paretic-side foot of hemiplegic patients, as well as to provide the necessary information for applying balance training with hemiplegic patients. Methods: The subjects were divided into two groups: a spontaneous foot group and an asymmetrical foot group. They all performed repetitive sit-to-stand training five times a week for a total of six weeks. The sit-to-standing movement was studied using standardized clinical tests. The Biodex Balance System, Time up and go test (TUG), 5 times sit-to-stand test (5XSST), and functional reach test (FRT) were used to measure the static and dynamic standing balance of the patients. Results: In the balance system measurement, the results for the overall index, ant-post index, med-lat index, fall risk index, 5XSST, and FRT after the training differed significantly between the comparison groups (p<0.05). In the evaluation of dynamic balance, the differences in TUG did not differ significantly between the comparison groups after the training (p>0.05). Conclusion: The study found that the asymmetrical group showed significant increases in static and dynamic balance in comparison to the spontaneous group after repetitive sit-to-stand training. Based on this result, it is clear that training in an asymmetrical position with the paretic foot back can increase the left-right stability limit and the anterior-posterior stability limit, thus improving balance control.

하프 브리지 컨버터의 비대칭 제어 공진 특성 분석 (Analysis of Resonant Characteristics in Asymmetrical Control Half Bridge Converter)

  • 안중록;권명일;장도현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.58-61
    • /
    • 2003
  • In this paper, resonant Characteristics of the soft switched asymmetrical half bridge converter is analysis. The operation principle for proposed converter is explained in steady state and its circuit is analyzed by means of equivalent circuit. Experimental results carried out on a system prototype are included in this paper.

  • PDF

넓은 입력 전압 범위를 갖는 새로운 비대칭 PWM 방식의 양방향 하프브리지 컨버터 (A New Asymmetrical PWM Bidirectional Half Bridge Converter for Wide Input Voltage Range Applications)

  • 김정근;최세완;박래관;장서건
    • 전력전자학회논문지
    • /
    • 제14권3호
    • /
    • pp.235-242
    • /
    • 2009
  • 본 논문에서는 새로운 비대칭 PWM 제어 방식의 양방향 하프브리지 컨버터를 제안한다. 제안한 컨버터는 구조가 간단하고 넓은 듀티 범위를 가지므로 연료전지와 같은 넓은 전압변동을 가지는 응용에 적합하다. 제안한 비대칭 PWM 방식은 기존의 위상각제어 방식에 비해 스위치 및 변압기의 동작전류를 큰 폭으로 낮추었고 ZVZCS와 동기 정류 방식을 적용하여 높은 효율과 전력밀도를 가질 수 있다. 기존 컨버터와의 비교 분석을 수행하였으며 실험을 통해 본 방식의 타당성을 검증하였다.

A Tightly Regulated Triple Output Asymmetrical Half Bridge Flyback Converter

  • Hyeon, Byeong-Cheol;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.14-20
    • /
    • 2010
  • In this paper, a tightly regulated triple output asymmetrical half bridge flyback (ASHF) converter is proposed. In order to regulate all output voltages, pulse frequency modulation (PFM), pulse width modulation (PWM) and phase delay (PD) are used simultaneously. In comparison with the conventional PWM-PD method, the interactions among the control variables are minimized and the operating range is increased. By the utilization of a multi winding transformer, the auxiliary transformer and the blocking capacitor are eliminated and the size and cost of the proposed converter is reduced. The operation principle of the converter is explained and the modes of operation are investigated. Based on the results, the steady state characteristics of the converter are explored. A 24V/10A, 12V/5A, 5V/10A hardware prototype is built and tested to verify the analysis results and the voltage regulation of the triple outputs of the proposed converter.

The Dimmable Single-stage Asymmetrical LLC Resonant LED Driver with Low Voltage Stress Across Switching Devices

  • Kim, Seong-Ju;Kim, Young-Seok;Kim, Choon-Taek;Lee, Joon-Min;La, Jae-Du
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2031-2039
    • /
    • 2015
  • In the LED lighting industry, the dimming function in the LED lamp is required by demands of many consumers. To drive this LED lighting, various types of power converters have been applied. Among them, an LLC resonant converter could be applied for high power LED lighting because of its high efficiency and high power density, etc. The function of power factor correction (PFC) might be added to it. In this paper, a dimmable single-stage asymmetrical LLC resonant converter is proposed. The proposed converter performs both input-current harmonics reduction and PFC using the discontinuous conduction mode (DCM). Also, the lower voltage stress across switching devices as well as the zero voltage switching (ZVS) in switching devices is realized by the proposed topology. It can reduce cost and has high efficiency of the driver. In addition, the regulation of the output power by variable switching frequency can vary the brightness of a light. In the proposed converter, one of the attractive advantages doesn’t need any extra control circuits for the dimming function. To verify the performance of the proposed converter, simulation and experimental results from a 300W prototype are provided.