• Title/Summary/Keyword: Assessment unit

Search Result 1,187, Processing Time 0.029 seconds

The Theory and Application of Diffusive Gradient in Thin Film Probe for the Evaluation of Concentration and Bioavailability of Inorganic Contaminants in Aquatic Environments (박막분산탐침(diffusive gradient in thin film probe)의 수중 생물학적 이용가능한 중금속 측정 적용)

  • Hong, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.5
    • /
    • pp.691-702
    • /
    • 2013
  • This review paper summarizes the theory, application, and potential drawbacks of diffusive gradient in thin film (DGT) probe which is a widely used in-situ passive sampling technique for monitoring inorganic contaminants in aquatic environments. The DGT probe employs a series of layers including a filter membrane, a diffusive hydrogel, and an ionic exchange resin gel in a plastic unit. The filter side is exposed to an aquatic environment after which dissolved inorganic contaminants, such as heavy metals and nuclides, diffuse through the hydrogel and are accumulated in the resin gel. After retrieval, the contaminants in the resin gel are extracted by strong acid or base and the concentrations are determined by analytical instruments. Then aqueous concentrations of the inorganic contaminants can be estimated from a mathematical equation. The DGT has also been used to monitor nutrients, such as ${PO_4}^{3-}$, in lakes, streams, and estuaries, which might be helpful in assessing eutrophic potential in aquatic environments. DGT is a robust in-situ passive sampling techniques for investigating bioavailability, toxicity, and speciation of inorganic contaminants in aquatic environments, and can be an effective monitoring tool for risk assessment.

Necessity of Adjustment of the Jurisdiction of Local Governments based on Watershed (유역(流域)을 기초로 한 행정구역경계설정의 필요성)

  • Lee, Won-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.10 no.3
    • /
    • pp.245-255
    • /
    • 2001
  • The management of water, both the quantity and the quality, has been one of the most important issues in the public investment and it is equally true in the field of sustainable development. Nevertheless, the jurisdiction of local governments has been delineated without much attention to the issue of the water management. In the planning of wide areas such as cities, countries, the metropolis, and the megalopolis, it is necessary to well arrange the geographical jurisdiction of local governments as a unit of region. The river water system, including small streams to large rivers, should be given its due share in the planning and jurisdictional delineation. The traditional concept of the local government's jurisdiction emphasizing the accessibility may be fading away. Instead, the efficiency of the public management would be the main concept in determining the jurisdiction of local governments. The river improvement, the waterworks, the sewage, the maintenance of water quality, the space of water recreation, are relatively important in the efficient management of that area. This paper argues for the equalization between the geographical jurisdiction of local governments and watersheds. To this end, I do case studies of the local governments areas such as Ri(里), Eup Myon(邑 面), Si Gun(市 郡), KyangyokSi Do(廣域市 道). The study interprets ARS will be one of the principles of land use and the reorganization of the local jurisdiction in the future as a geo-systematic and the eco-systematic criteria.

  • PDF

Comparative Evaluation of Indoor Temperature in Spring according to Sitting Orientation of Tower-Type Apartments (탑상형 아파트의 배치방향별 봄철 실내온도 비교평가)

  • Kim, Jun Hyun;Um, Jung-Sup
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 2011
  • It is usual for energy consumption in accordance with facing and sitting direction of tower-type apartments to be calculated by the official statistics or computer simulation. Previous studies for energy consumption appear to be very limited due to the dependence on flat type of apartment. Acknowledging these constraints, an empirical study for a tower type apartment was conducted to demonstrate how a on-site indoor temperature measurement in spring can be used to assist in estimating the total energy consumption in terms of facing and sitting orientation specific settings. The results indicate that maximum temperature difference in spring was identified as $1.16^{\circ}C$ between south and eastern direction. It is known that raising $1^{\circ}C$ indoor temperature require 7% more energy consumption than normal. The $1.16^{\circ}C$ difference means that sitting direction of tower type apartment is a crucial explanatory variable as unit of analysis for energy consumption. It was demonstrated that the indoor temperature could be used effectively as an indicator to estimate energy consumption among various sitting direction of tower type apartments. It is anticipated that this research output could be used as a valuable reference to support more scientific and objective decision-making for facing and sitting orientation of tower type apartments.

Charts for estimating rock mass shear strength parameters

  • Wan, Ling;Wei, Zuoan;Shen, Jiayi
    • Geomechanics and Engineering
    • /
    • v.10 no.3
    • /
    • pp.257-267
    • /
    • 2016
  • Charts are used extensively in slope practical application to meet the need of quick assessment of rock slope design. However, Charts for estimating the shear strength of the rock mass of a slope are considerably limited. In this paper, based on the Hoek-Brown (HB) criterion which is widely used in rock slope engineering, we present charts which can be used to estimate the Mohr-Coulomb (MC) parameters angle of friction ${\phi}$ and cohesion c for given slopes. In order to present the proposed charts, we firstly present the derivation of the theoretical relationships between the MC parameters and ${\sigma}_{ci}/({\gamma}H)$ which is termed the strength ratio (SR). It is found that the values of $c/{\sigma}_{ci}$ and ${\phi}$ of a slope depend only on the magnitude of SR, regardless of the magnitude of the individual parameters ${\sigma}_{ci}$(uniaxial compressive strength), ${\gamma}$(unit weight) and H (slope height). Based on the relationships between the MC parameters and SR, charts are plotted to show the relations between the MC parameters and HB parameters. Using the proposed charts can make a rapid estimation of shear strength of rock masses directly from the HB parameters, slope geometry and rock mass properties for a given slope.

Evaluation of Mental Status in High-Risk Neonates using Infants Coma Scale (고위험신생아의 의식수준 사정을 위한 Infants Coma Scale의 개발과 적용)

  • Ahn, Young-Mee;Sohn, Min;Lee, Sang-Mi
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.4
    • /
    • pp.561-570
    • /
    • 2010
  • Purpose: This was a cross sectional descriptive study to introduce the Infants Coma Scale (ICS), describe mental status of high risk infants using ICS and explore the relationships between ICS and clinical variables in infants hospitalized in a neonatal intensive care unit of a university hospital in Korea. Methods: After ICS was developed and tested by the authors, a research nurse evaluated the mental status of the infants using the English version of ICS and obtained clinical information on the infants from their medical records. Results: Data from 88 infants were analyzed. About 60% were male, 90% were preterm births, and 40% had pathologic abnormalities. Their mean gestational age was 32.4 (${\pm}3.50$) weeks and the mean birth weight was 1,842 (${\pm}728.6$) grams. The Cronbach's alpha for the ICS was .78. There was a statistically significant positive correlation between ICS total score and five clinical variables including gestational age, birth weight, 1 and 5 min Apgar scores and respiration status. Conclusion: Mental status is an important parameter in nursing assessment. ICS is a valid and reliable instrument, which clinicians can easily use to evaluate the mental status of high risk infants.

Analysis of Musculoskeletal Burdened Work among Nurses at a University Hospital (일개 대학병원 간호사의 근골격계 부담작업 분석)

  • Jeong, Eun-Hee;Koo, Jung‐Wan
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.97-103
    • /
    • 2006
  • Severities of musculoskeletal diseases (MSDs) have been recognized at the regular work such as manufacturing but incidence of MSDs are increasing also at the atypical work. The examples of those are health medical workers, office workers and service workers etc. Nurses among health medical workers are accomplishing to manage and recover the patients' health in the first place. Therefore, they are exposed to very stressful work conditions during caring the patients. This study was performed to analyze the musculoskeletal burdened work among nurses at a university hospital, in order to grasp the realities of the MSDs, analyze and prevent MSDs. We surveyed risk factors for ward, intensive care unit, delivery room, newborn room, operation room, function test room and central supply room at a university hospital in Seoul. It was executed for 2 months as the field study that was composed of simulation, real measurement, work motion assessment and subjective assessment. And the results were analyzed into ergonomics techniques. Works according to the criteria of musculoskeletal burdened work by the Ministry of Labor were scrub in operation room and heart ultrasonic function test. And a lot of works that need attention and management were also detected. So it should be required the education and systematic managements of MSDs for nurses.

Basic Design of Software for Eco-Efficiency Assessment of Electric Motor Unit(EMU) (전동차 에코효율성 평가를 위한 S/W 기본설계)

  • Kim, Yong-Ki;Lee, Jae-Young;Seo, Min-Seok;Eun, Jong-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1253-1258
    • /
    • 2006
  • As a global effort to conservate the environment, life cycle assessment(LCA) which considers the environmental impact through the life cycle of a product, from acquiring of resources to scrapping, has been actively applied. The LCA is a tool to calculate quantitatively the environmental impacts caused by products or services through their life cycles. Eco-efficiency need that express value of environmental impact provision EMU and develops in two forms according to use target of Eco-efficiency as a tool that environmental impact of EMU. It is a strategic instrument which assists stakeholders to understand which products, processes or services to target with future investments and which are not by comparing economic and ecological values. The results stand for aggregated information on economical value and environmental impact. Also, In this method, it is important to derive EPI(Environmental Performance Index) and SPI(Service Performance Index) from the sources available. The following is used as one of Eco-efficiency tools to achieve the target performance of processes, products and services for designer or projector. According to the eco-efficiency methodology for EMU developed in this study, the user definition and the DB design were carried out as a basic design of eco-efficiency S/W.

  • PDF

Design and Fabrication of High Frequency Ground Impedance Measuring System for Assessment of Grounding System for Lightning Protection (낙뢰 보호용 접지시스템 평가를 위한 고주파 접지임피던스 측정시스템의 설계 및 제작)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min;Kim, Young-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.47-52
    • /
    • 2016
  • This paper describes the design and fabrication of high frequency ground impedance measuring system for assessment of grounding system for Lightning protection. The ground impedance measuring system has been designed and fabricated which makes it possible to assess the ground impedance by frequency ranges from 100 Hz to 1 MHz. The effective grounding systems having a very low impedance to electromagnetic disturbance such as lightning surges and noises in microelectronics and high-technology branches are strongly required. In order to analyze the dynamic characteristic of grounding system impedances in lightning and surge protection grounding systems, it is highly desirable to assess the ground impedances as a measure of performance of grounding system in which lightning and switching surge currents with fast rise time and high frequency flow. The measuring system is based on the variable frequency power supply and consists of signal circuit part, main control part, data acquisition and processing unit, and voltage and current probe system. The ground impedance measuring system can be used to assess grounding system during occurrence of lightning.

A Study on Development of Lightweight Foam Filling Material for the Voids behind Tunnel Liner using Stone-dust and Application to the Old Tunnel (석분을 이용한 터널 뒤채움용 경량기포 충전재의 개발과 현장적용에 대한 연구)

  • Ma, Sang-Joon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.139-147
    • /
    • 2003
  • The most tunnel damage such as cracks or leakage which exist in tunnel lining commonly, is caused by the voids where exist behind the tunnel lining, through the tunnel safety inspections. These voids were analysed to affect to a stability of a running-tunnel seriously. The aim of this paper is to develope the lightweight foam concrete for tunnel backfilling material using stone-dust of cake state and to apply the lightweight foam concrete developed to the old tunnel. This paper shows the basic properties of lightweight foam concrete mixed with stone-dust including flow rate, unit volume weight, absorption rate and compressive strength. In addition, according to the designed compound ratio, the lightweight foam concrete was applied to the ASSM tunnel for an application assessment. The engineering application of the lightweight foam concrete as the old tunnel's backfilling material was confirmed in this assessment.

Influence of Death Perception, Attitude Toward Terminal Care, Mental Health on the Terminal Care Stress of Intensive Care Unit Nurses (중환자실 간호사의 죽음 인식, 임종간호 태도, 정신건강이 임종간호 스트레스에 미치는 영향)

  • Hwang, Jung Ok;Kim, Sang Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.3
    • /
    • pp.323-332
    • /
    • 2019
  • Purpose: This study aimed to identify the factors affecting the terminal care stress of nurses in intensive care units in terms of their death perception, attitude toward terminal care, and mental health. Methods: This descriptive study collected data from 118 nurses in intensive care units in one tertiary referral hospital and three general hospitals. The instruments used in the study were the Terminal Care Stress Assessment Tool, the View of Life and Death Scale, the Frommelt Attitudes toward Nursing Care of the Dying Scale (FATCOD), and the Mental Health Assessment Tool. The data were analyzed by t-test, ANOVA, Pearson's correlation coefficient, and multiple regression. Results: There was a significant positive correlation between terminal care stress and death perception (r=.31, p<.001). The factors significantly influencing the terminal care stress of the participants included gender (β=.33, p<.001), religion (β=.24, p=.004), and death perception (β=.35, p<.001), and the overall explanatory power was 23.1% (F=12.73, p<.001). Conclusion: To decrease terminal care stress among nurses, establishing the death perception of nurses based on value clarification about death may be necessary. Furthermore, this study suggests an intervention study examining the effect of an education program on terminal care stress among ICU nurses.