• Title/Summary/Keyword: Assessment of deterioration

Search Result 332, Processing Time 0.03 seconds

Modified indirect evaluation method for deterioration assessment of drinking water pipes (상수도 노후도 평가를 위한 수정 간접평가법)

  • Kwon, Hyuk Jaea
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.11
    • /
    • pp.697-703
    • /
    • 2023
  • In this study, a modified indirect evaluation method was developed to predict the deterioration level of water pipes. The accuracy of the modified method was verified by comparing it with the direct method. The weights of index were adjusted by reducing the weight of water quality corrosion, soil corrosion, lay depth and road type according to the importance of the existing evaluation factors and adding the weight of pipe thickness. In the results, the weight of pipe thickness was determined to be 0.1530. Comparing with the direct evaluation method, the accuracy of the modified indirect evaluation method increased by 31.03% compared to the indirect evaluation method. The modified indirect evaluation method will be able to select relatively old pipes more accurately and efficiently than the existing indirect evaluation method when prioritizing the improvement of old water pipes.

Variable Emission Factor Prediction Model for An Air Quality Assessment of Transportation Projects (교통사업의 대기질 평가를 위한 가변적 배출계수 예측모형)

  • Lee, Gyu-Jin;Choe, Gi-Ju;Yu, Jeong-Hun;O, Se-Chang
    • Journal of Korean Society of Transportation
    • /
    • v.29 no.6
    • /
    • pp.117-128
    • /
    • 2011
  • In this study, a model is developed to predict emission factors, which aims to objectively evaluate the impact of transport projects on air quality. Two emission prediction models for the years of 2015 and 2030 are developed using the historical trends in vehicle aging and vehicle deterioration factors. The analysis results show that the emission factors under the operating speed of 30km/h for the year 2030 are 5~37% and 2~83% less than those used in the current studies for passenger cars and bus/trucks, respectively. The statistically validated experiment results demonstrate the applicability of the proposed model to evaluation of the impact of transport policies on air quality.

Material Characteristics and Deterioration Assessment of the Stone Buddhas and Shrine in Unjusa Temple, Hwasun, Korea (화순 운주사 석조불감의 재질특성과 풍화훼손도 평가)

  • Park, Sung-Mi;Lee, Myeong-Seong;Choi, Seok-Won;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.24
    • /
    • pp.23-36
    • /
    • 2008
  • The stone Buddhas and Shrine of Unjusa temple (Korea Treasure No. 797) in Hwasun formed in Koryo Dynasty are unique style which the Buddha faces each other the back parts of south and north within the stone Shrine. The stone Buddhas and Shrine are highly evaluated in historical, artistic and academic respects. But, the stone properties have been exposed in the open system various aspects of degradations weathered for a long time without specific protective facilities. The rock materials of the stone Buddhas and Shrine are about 47 blocks, and total press load is about 56.6 metric ton. The host rocks composed mainly of white grey hyaline lithic tuff and rhyolitic tuff breccia. In addition, biotite granite used as part during the restoration works. The chemical index of alteration for host tuffaceous rocks and the replacement granites range from 52.1 to 59.4 and 50.0 to 51.0, respectively. Weathering types for the stone Buddhas and Shrine were largely divided with physical, chemical and biological weathering to make a synthetic deterioration map according to aspects of damage, and estimate share as compared with surface area. Whole deterioration degrees are represented that physical weathering appeared exfoliation. Chemical weathering is black coloration and biological weathering of grey lichen, which show each lighly deterioration degrees. According to deterioration degree by direction of stone Buddhas and Shrine, physical weathering mostly appeared by 39.1% on the sorthern part, and chemical weathering is 61.2% high share on the western part. Biological weathering showed 38.3% the largest distribution on the southern part. Therefore, it is necessary to try hardening for the parts with serious cracks or exfoliations, remove secondary contaminants and organisms through regular cleaning. Also necessary to make a plan to remove moisture of the ground which causes weathering, and estimate that need established and scientific processing through clinical demonstration of conservation plan that chooses suitable treatment.

  • PDF

Estimation of Structural Deterioration of Sewer using Markov Chain Model (마르코프 연쇄 모델을 이용한 하수관로의 구조적 노후도 추정)

  • Kang, Byong Jun;Yoo, Soon Yu;Zhang, Chuanli;Park, Kyoo Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.421-431
    • /
    • 2023
  • Sewer deterioration models can offer important information on prediction of future condition of the asset to decision makers in their implementing sewer pipe networks management program. In this study, Markov chain model was used to estimate sewer deterioration trend based on the historical structural condition assessment data obtained by CCTV inspection. The data used in this study were limited to Hume pipe with diameter of 450 mm and 600 mm in three sub-catchment areas in city A, which were collected by CCTV inspection projects performed in 1998-1999 and 2010-2011. As a result, it was found that sewers in sub-catchment area EM have deteriorated faster than those in other two sub-catchments. Various main defects were to generate in 29% of 450 mm sewers and 38% of 600 mm in 35 years after the installation, while serious failure in 62% of 450 mm sewers and 74% of 600 mm in 100 years after the installation in sub-catchment area EM. In sub-catchment area SN, main defects were to generate in 26% of 450 mm sewers and 35% of 600 mm in 35 years after the installation, while in sub-catchment area HK main defects were to generate in 27% of 450 mm sewers and 37% of 600 mm in 35 years after the installation. Larger sewer pipes of 600 mm were found to deteriorate faster than smaller sewer pipes of 450 mm by about 12 years. Assuming that the percentage of main defects generation could be set as 40% to estimate the life expectancy of the sewers, it was estimated as 60 years in sub-catchment area SN, 42 years in sub-catchment area EM, 59 years in sub-catchment area HK for 450 mm sewer pipes, respectively. For 600 mm sewer pipes, on the other hand, it was estimated as 43 years, 34 years, 39 years in sub-catchment areas SN, EM, and HK, respectively.

Influence of Carbonation on the Chloride Diffusion in Concrete (탄산화 현상이 콘크리트 중의 염소이온 확산에 미치는 영향 연구)

  • Oh, Byung-Hwan;Lee, Sung-Kyu;Lee, Myung-Kue;Jung, Sang-Hwa
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.6
    • /
    • pp.829-839
    • /
    • 2003
  • Recently, the corrosion of reinforced concrete structures has received great attention related with the deterioration of sea-side structures, such as new airport, bridges, and nuclear power plants. In this regards, many studies have been done on the chloride attack in concrete structures. However, those studies were confined mostly to the single deterioration due to chloride only, although actual environment is rather of combined type. The purpose of the present study is, therefore, to explore the influences of carbonation to chloride attack in concrete structures. The test results indicate that the chloride penetration is more pronounced than the case of single chloride attack when the carbonation process is combined with the chloride attack. It is supposed that the chloride ion concentration of carbonation region is higher than the sound region because of the separation of fixed salts. Though the use of fly ash pronounces the chloride ion concentration in surface, amounts of chloride ion penetration into deep region decreases with the use of fly ash. The present study allows more realistic assessment of durability for such concrete structures which are subjected to combined attacks of both chlorides and carbonation but the future studies for combined environment will assure the precise assessment.

Deterioration Assessment and Structural‐Reinforcement of Stone Lantern of the Four Guardian Kings in Beopjusa Temple, Boeun (보은 법주사 사천왕석등의 비파괴 훼손도 평가 및 구조보강)

  • Choie, Myoungju;Lee, Myeong Seong;Jun, Yu Gun;Lee, Mi Hye;Kim, Yuri;Ha, Jun Kyeong
    • Journal of Conservation Science
    • /
    • v.33 no.1
    • /
    • pp.25-33
    • /
    • 2017
  • The stone lantern of the four guardian kings in the Beopjusa temple at Boeun was mainly made of biotite granodiorite consisting of porphyritic-textured potassium feldspar and included in ilmenite series. A base stone made of alkali granite was buried, after founded its place during an earlier restoration process. Cracking and break out are noticeable on this object. In addition, discoloration, salt crusting, and epiphytes were observed. The lantern was vulnerable in terms of physical and structural stability caused by cracking in the front and back of the light chamber and in the non-horizontal direction. According to the conservational condition of the stone lantern, structural reinforcement was carried out based on calculations, including those on the position, size, and anchor length of the titanium stiffener. Chemical and biological pollutants were washed off without damage to the surface of the stone material. Oxygenated iron pieces were replaced with titanium. Ethyl silicate was applied to the surface of the lantern for consolidation and smooth drainage.

Experimental Study on Chloride Penetration into Concrete under Combined Exposure Conditions of Chlorides and High Concentrated Sulfates (고농도 황산염 이온이 함께 존재하는 경우의 염소이온 침투특성에 관한 실험 연구)

  • Oh, Byung-Hwan;Jung, Sang-Hwa;Jiang, Yi-Rong;Kim, Jee-Sang
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.2
    • /
    • pp.173-182
    • /
    • 2003
  • Recently, the durability of concrete structures has received great attention as the number of sea-side structures, such as new airport, bridges, and nuclear power plants, increases continuously. In this regards, many studies have been done on the chloride attack in concrete structures. However, those studies were confined mostly to the single deterioration due to chloride only, although actual environment is rather of combined type. The purpose of the present study is, therefore, to explore the effects of combined deterioration due to chlorides and sulfates in concrete structures. To this end, comprehensive experimental program has been set up to observe the chloride penetration behavior for various test series. The test results indicate that the chloride penetration is more pronounced for the case of combined attack than the case of single chloride attack. The surface chloride content is found to increase with time and the diffusion coefficient for chloride is found to decrease with time. The prediction equations for surface chloride content and diffusion coefficient were proposed according to test results. The equations for chloride penetration considering the time-dependent diffusion coefficients and surface chlorides were also suggested. The present study allows more realistic assessment of durability for such concrete structures which are subjected to combined attacks of chlorides and high concentration sulfates but the future studies for combined environment will assure the precise assessment.

Theoretical analysis of erosion degradation and safety assessment of submarine shield tunnel segment based on ion erosion

  • Xiaohan Zhou;Yangyang Yang;Zhongping Yang;Sijin Liu;Hao Wang;Weifeng Zhou
    • Geomechanics and Engineering
    • /
    • v.37 no.6
    • /
    • pp.599-614
    • /
    • 2024
  • To evaluate the safety status of deteriorated segments in a submarine shield tunnel during its service life, a seepage model was established based on a cross-sea shield tunnel project. This model was used to study the migration patterns of erosive ions within the shield segments. Based on these laws, the degree of deterioration of the segments was determined. Using the derived analytical solution, the internal forces within the segments were calculated. Lastly, by applying the formula for calculating safety factors, the variation trends in the safety factors of segments with different degrees of deterioration were obtained. The findings demonstrate that corrosive seawater presents the evolution characteristics of continuous seepage from the outside to the inside of the tunnel. The nearby seepage field shows locally concentrated characteristics when there is leakage at the joint, which causes the seepage field's depth and scope to significantly increase. The chlorine ion content decreases gradually with the increase of the distance from the outer surface of the tunnel. The penetration of erosion ions in the segment is facilitated by the presence of water pressure. The ion content of the entire ring segment lining structure is related in the following order: vault < haunch < springing. The difference in the segment's rate of increase in chlorine ion content decreases as service time increases. Based on the analytical solution calculation, the segment's safety factor drops more when the joint leaks than when its intact, and the change rate between the two states exhibits a general downward trend. The safety factor shows a similar change rule at different water depths and continuously decreases at the same segment position as the water depth increases. The three phases of "sudden drop-rise-stability" are represented by a "spoon-shaped" change rule on the safety factor's change curve. The issue of the poor applicability of indicators in earlier studies is resolved by the analytical solution, which only requires determining the loss degree of the segment lining's effective bearing thickness to calculate the safety factor of any cross-section of the shield tunnel. The analytical solution's computation results, however, have some safety margins and are cautious. The process of establishing the evaluation model indicates that the secondary lining made of molded concrete can also have its safety status assessed using the analytical solution. It is very important for the safe operation of the tunnel and the safety of people's property and has a wide range of applications.

Study on the Physical Properties and Characteristics of Adhesives for Woodcraft (목공예용 천연 및 합성 접착제의 특성 연구)

  • Kim, Seong Eun;Lee, Jin Kyung;Lee, Chae Hoon;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.35 no.6
    • /
    • pp.681-688
    • /
    • 2019
  • In this study, the characteristics of natural and synthetic adhesives used in woodcraft were evaluated. The pattern of deterioration of wood and adhesives according to changes in temperature and humidity were compared. For materials, one type of anlmal glue, three kinds of polyvinyl acetate adhesives, one type of epoxy adhesive and one type of zelkova wood were selected. Characteristics of physical and chemical characteristics, weather resistance and drying speed assessment were carried out. The adhesion characteristic evaluation showed that the adhesion strength of anlmal glue and one type of polyvinyl acetate adhesive were 6.54 N/㎟ and 7.01 N/㎟, pH meter of anlmal glue and polyvinyl acetate adhesives was pH 7.03 and pH 3.32-3.59 which were range of available as an adhesive. According to the test results of weather resistance, epoxy adhesives had the highest decreasing value in adhesion strength after deterioration. In the reversible test of the adhesive, it was found to be highly reversible in NaOH, a soluble solvent excluding epoxy, but attention is required when using the wood since it may show discoloration during processing.

Deterioration Evaluation and Material Characteristics of the Usuki Stone Buddha Statues in Oita, Japan (일본 오이타현 우스키 마애불상군의 재질특성 및 손상도 평가)

  • Cho, Ji-Hyun;Lee, Chan-Hee;Kim, Ji-Young;Morii, Masayuki;Lee, Myeong-Seong;Kim, Sa-Dug
    • Journal of Conservation Science
    • /
    • v.28 no.1
    • /
    • pp.39-52
    • /
    • 2012
  • The Usuki Stone Buddha Statues in Oita are consisted of 60 Buddhas which represent of Japan carved on the rock-cliff in the 12 to 14th centuries. The basement rock of the statues is dark gray welded lapilli tuff that containing the Aso-4 pyroclastic rock group. Deterioration maps for the Hoki I and the Furuzono Buddha Statues group show multi-directional fissures on the Cakra, and sheeting-off zone at the margin of uprising water. Deterioration rate of the Hoki I group was calculated fissure about 121 in number, 19% of sheeting-off zone and 51% of biological weathering in surface of area. And the Furuzono group was also evaluated as about 48 of fissures in number, 24% of sheeting-off zone and 41% biological weathering. The slope stability assessment results, the Hoki I developed discontinuous planes has possibility of planar, toppling and wedge failures in all caves. Ultrasonic velocity of the Aizen-myooh (basement rock) ranges from 1,520 to 2,794 (average 2,298m/s). And pedestal of Amita-yeorae which has been replaced by new fresh rock is measured as 3,242 to 4,141 (average 3,813m/s). Therefore, we establish of planing conservation treatment and reinforcement methods to fissure, cavity, sheeting-off zone in the Buddha surface.