• Title/Summary/Keyword: Assessment guidelines

Search Result 1,055, Processing Time 0.033 seconds

An Analysis and Evaluation of Cyber Home Study Contents for Self-directed Learning - Focused on the Earth Science Content of the Science Basic Course for the 7th grade - (사이버가정학습의 자율학습용 콘텐츠 분석 및 평가 - 중학교 1학년 과학 기본과정 지구과학영역을 중심으로 -)

  • Na, Jae-Joon;Son, Cheon-Jae;Kook, Dong-Sik
    • Journal of the Korean earth science society
    • /
    • v.31 no.4
    • /
    • pp.392-402
    • /
    • 2010
  • The purpose of this study is to analyze and evaluate the self-directed learning contents of Earth science area in the basic course of the 7th grade. For this purpose, we applied the 'Cyber Home Study Content Quality Control Tool' presented in 'Elementary Secondary Education e-Learning Quality Management Guidelines (Ver.2.0)' of Korea Education & Research Information Service (2008). The results of contents analysis are as follow: First, it was presented that the study guide introduced the contents which should be studied for one class, properly. And it was not analyzed that the diagnosis assesment was not completed in the initiative study; Second, it was possible to study choosing the contents fitting the learner's level of learning in the main study, it was comprised of about 15 minutes. Third, it was performed without feedback for incorrect answers in the learning assessment, just the number of wrong questions. And the learning arrangement present the important contents learned in that class, summarizing and arranging again. The results of content evaluation are as follows: First, a big difference was not showed against the needs analysis, instructional design, interaction in each class. And the evaluation of the ethics was not included a word or sentence not suitable. The evaluation of copyright, it was analyzed that Work within the content display in compliance with international copyright Second, the evaluation of instructional design presented mainly the description of a simple picture based, the visible resources like flash card were poor. And in the evaluation of Supporting System, it was presented that the contents were installed so that it was freely available for learners. But it was analyzed that there was no memo-function learners were able to jot down something during the studying contents. And in the evaluation for evaluation, the clear valuation basis about the described content was not presented. So there were slightly differences for each class. Third, in the evaluation and analysis for learning content, it was presented that there were some big differences for each class because it was not composed of the latest information, not corrected and complementary.

Elementary Teachers' Perception in Using Smart-Technology in STEAM Class : Focus on Application Type, Difficulties and Support Required (STEAM 수업에서 스마트테크놀로지 적용에 대한 초등교사의 인식 -적용 유형과 어려움 및 지원을 중심으로-)

  • Han, Areum;Na, Jiyeon
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.6
    • /
    • pp.777-790
    • /
    • 2019
  • The purpose of this study is to investigate the experience of teachers who apply Smart-technology in elementary school STEAM class and the reasons, difficulties when applying the technology and required support. Semi-structured in-depth interviews were conducted with six elementary school teachers with specialized knowledge in STEAM education who have experienced STEAM lessons several times before. The research findings are as follows: First, research participants utilized a variety of Smart-technology in STEAM class, most of which were experiential or interactive technology. Among the STEAM learning criteria, the Smart-technology in 'Creative Design' course was most often applied. Second, they adopted Smart Technology in STEAM class to encourage students to feel interested, actively participate in the class, enjoy indirect experience, and nurture interest in state-of-the-art technology. They used it to prepare for future societies and organize classes that are suitable for STEAM learning criteria. They also used Smart-technology because it was easy to use. Third, they found it difficult to find, secure, and use suitable Smart-technology when applying Smart-technology in the STEAM class. They also had trouble restructuring the curriculum. In addition, there were difficulties in using Smart-technology in the class such as lack of class hours, increased level of activity, insufficient physical environment and unexpected malfunction of Smart-technology, thus interrupted the class. After the class, it was hard to manage Smart-technology and also, there were difficulties in assessment, record, and negative awareness of surrounding people. Fourth, they mentioned that's suggesting education guidelines, develop, and distribute educational materials are required to enable 'Creative Design,' reduce educational content, provide training, secure Smart-technology equipment and provide Wi-Fi, support teacher's club and communities and create an atmosphere to emotionally support teachers in order to activate using Smart-technology in STEAM class.

Proposal of New Criteria for Assessing Respiratory Impairment (새로운 호흡기 장애 판정 기준의 제안)

  • Park, Joo-Hun;Lee, Jae-Seung;Huh, Jin-Won;Oh, Yeon-Mok;Lee, Sang-Do;Lee, Sei-Won;Yoon, Ho-Il;Kim, Deog-Kyeom;Lee, Chang-Hoon;Park, Myung-Jae;Kim, Eun-Kyung;Park, Yong-Bum;Hwang, Yong-Il;Jung, Ki-Suck;Park, Hye-Yoon;Lim, Seong-Yong;Jung, Ji-Ye;Kim, Young-Sam;Kim, Hui-Jung;Rhee, Chin-Kook;Yoon, Hyoung-Kyu;Kim, Young-Kyoon;Kim, Jin-Woo;Yoo, Jee-Hong;Yoo, Kwang-Ha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.70 no.3
    • /
    • pp.199-205
    • /
    • 2011
  • Social welfare services for respiratory-disabled persons in Korea are offered based on the respiratory impairment grade, which is determined by 3 clinical parameters; dyspnea, forced expiratory volume in 1 second ($FEV_1$), and arterial oxygen tension. This grading system has several limitations in the objective assessment of respiratory impairment. We reviewed several guidelines for the evaluation of respiratory impairment and relevant articles. Then, we discussed a new grading system with respiratory physicians. Both researchers and respiratory physicians agreed that pulmonary function tests are essential in assessing the severity of respiratory impairment, forced vital capacity (FVC), $FEV_1$ and single breath diffusing capacity ($DL_{co}$) are the primarily recommended tests. In addition, we agreed that arterial blood gas analysis should be reserved for selected patients. In conclusion, we propose a new respiratory impairment grading system utilizing a combination FVC, $FEV_1$ and $DL_{co}$ scores, with more social discussion included.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Clinical Value of a Desktop Spirometer (HI-801) for Spirometry Screening (선별 검사를 위한 탁상용 폐활량기 (HI-801)의 임상적 유용성에 관한 고찰)

  • Choi, Hye Sook;Choi, Cheon Woong;Park, Myung Jae;Kang, Hong Mo;Yoo, Hong Ji
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.4
    • /
    • pp.276-283
    • /
    • 2007
  • Background: A national health care initiative recommends routine spirometry screening of all smokers over age 45 or patients with respiratory symptoms. In response to the recommendation, new, simple, and inexpensive desktop spirometers for the purpose of promoting widespread spirometric screening were marketed. The performance of these spirometers was evaluated in vivo testing with healthy subjects. However, the clinical setting allows spirometric assessment of various pathologic combinations of flow and volume. Objective: The aim of this study was to compare the accuracy of a desktop spirometer to a standard laboratory spirometer, in a clinical setting with pathologic pulmonary function. Method: In a health check-up center, where screening pulmonary funct test was performed using the HI-801 spirometer. Subjects who revealed the ventilation defect in screening spirometry, performed the spirometry again using the standard Vmax spectra 22d spirometer in a tertiary care hospital pulmonary function laboratory. Pulmonary function test with both spirometer was performed according to the guidelines of the American Thoracic Society. Results: 109 patients were enrolled. Pulmonary function measurements (FVC, $FEV_1$, PEFR, FEF25%-75%) from the HI-801 correlated closely (r=0.94, 0.93, 0.81, 0.84, respectively) with those performed with the Vmax spectra 22d and showed the good limits of agreement and differences between the 2 devices; FVC +0.35 L, $FEV_1$ +0.16 L, PEFR +1.85 L/s, FEF25%-75%-0.13 L/s. With the exception of $FEV_1$, FEF25%-75%, these differences were significant(p<0.05) but small. Conclusion: The HI-801 spirometer is comparable to the standard laboratory spirometer, Vmax spectra 22d, with high accurary for $FEV_1$ and FVC and acceptable differences for clinical use.

The Acceptance Testing of 5 Mega Pixels Primary Electronic Display Devices and the Study of Quality Control Guideline Suitable for Domestic Circumstance (5 Mega 화소 진단용 전자표시장치 인수검사 및 국내 실정에 적합한 정도관리 가이드라인 연구)

  • Jung, Hai-Jo;Kim, Hee-Joung;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.98-106
    • /
    • 2007
  • In June 2005, Yonsei University Medical Center, Severance Hospital upgraded a full-PACS system by adding twenty (5 mega pixels) Totoku ME511L flat panel LCD display devices for diagnostic interpretation purposes. Here we report upon the quantitative (or visual) acceptance testing of the twenty Totoku ME511L display devices for reflection, luminance response, luminance spatial dependency, resolution, noise, veiling glare, and display chromaticity based on AAPM TG 18 report. The tools used in the tests included a telescopic photometer, which was used as a colorimeter, illuminance meter, light sources for reflection assessment, light-blocking devices, and digital TG18 test patterns. For selected 8 flat panel displays, mean diffuse reflection coefficient ($R_d$) was $0.019{\pm}0.02sr^{-1}$. In the luminance response test, luminance ratio (LR), maximum luminance difference ($L_{max}$), and deviation of contrast response were $550{\pm}100,\;2.0{\pm}1.9%\;and\;5.8{\pm}1.8%$, respectively. In the luminance uniformity test, maximum luminance deviation was $14.3{\pm}5.5%$ for the 10% luminance of the TG18-UNL10 test pattern. In the resolution test with luminance measurement method, percent luminance (${\Dalta}L$) at the center was $0.94{\pm}0.64%$. In all cases of noise testing, rectangular target In every square in the three quadrants was visible and all 15 targets except the smallest one in the every corner pattern and the center pattern. The glare ratio (GR) was $12,346{\pm}1,995$. The color uniformity, (u',v'), was $0.0025{\pm}0.0008$. Also, the research results of qualify control guideline of primary disply devices suitable for domestic circumstance are presented All test results are in-line with the criteria recommended by AAPM TG18 report and are thus fully acceptable for diagnostic image interpretation. As a result, the acceptance testing schedule described provides not only an acceptance standard but also guidelines for quality control, optimized viewing conditions, and a means for determining the upgrading time of LCD display devices for diagnostic interpretation.

  • PDF

The Assessment for Nutrient Intakes of Korean Patients with Heart Failure (우리나라 일부 심부전 환자의 영양소 섭취량 평가 연구)

  • Lee, Hye-Ran;Kang, Bo-Rum;Chung, Hye-Kyung;Do, Hyun-Joo;Shim, Jee-Seon;Bae, Soon-Hwa;Kang, Seok-Min;Shin, Min-Jeong
    • Journal of Nutrition and Health
    • /
    • v.43 no.3
    • /
    • pp.224-232
    • /
    • 2010
  • The prevalence of heart failure (HF) is increasing globally and growing evidence has shown that dietary factors play an important role in preventing and improving prognosis of HF. However, little data on nutrient intake in Korean HF patients which are available to develop dietary guidelines for HF. The aims of this study were to estimate nutrient intake in 78 HF patients and evaluate whether the estimated nutrient intake is appropriate compared to dietary reference intake for Koreans. Data are presented as the ratio of actual intake and estimated average requirement (EAR) for each nutrient. The result showed that the average nutrient intakes including total energy and protein met EAR in total patients. However, the deficiencies in mineral and vitamin intakes were found. Moreover, the proportion of subjects with lower intake than EAR was substantial. The results showed that the proportion of male HF patients with inferior intakes to EAR in calcium, potassium (compared to adequate intake: AI), folate and vitamin $B_{12}$ were 38%, 79%, 38%, and 65%, respectively. Also, the proportion of female HF patients with inferior intakes to EAR in calcium, potassium (compared to AI), folate and vitamin $B_{12}$ were 35%, 88%, 38% and 40%, respectively. In particular, the elderly with HF ($\geq$ 70 yrs, n = 28) showed more serious deficiencies in calcium, potassium (compared to AI), folate and vitamin $B_{12}$. In summary, the intakes of potassium, calcium, folate, and vitamin B12 were not sufficient to meet EAR in HF patients. Furthermore, the proportions of subjects with lower intake than EAR in these nutrients were substantial, raising the possibility that these micronutrients may be involved in the pathogenesis of HF. Practical dietary guideline for HF patients is needed to improve prognosis of HF.

Comparison of Toxic Response of Cladocerans to Organic Solvents to Establish the Standard Test Guidelines Using Korean Native Species (한국산 물벼룩 표준생태독성시험법 확립을 위한 10종 용매대조물질에 대한 독성반응 비교)

  • Kim, Byung-Seok;Park, Yoen-Ki;Yang, Yu-Jung;Hong, Soon-Sung;Park, Kyung-Hun;Jeong, Mi-Hye;Kim, Se-Ri;Park, Kyeong-Hun;Yeh, Wan-Hae;Kim, Doo-Ho;Yun, Jong-Chul;Hong, Moo-Ki;Kyung, Kee-Sung;Ahn, Young-Joon
    • The Korean Journal of Pesticide Science
    • /
    • v.14 no.1
    • /
    • pp.10-15
    • /
    • 2010
  • Most pesticides are poorly soluble in water and must be dissolved in a solvent carrier before being added to the test medium on aquatic toxicity test. The concentration of solvent is critical to the success of a test. This study were conducted to recommend possible organic solvents which have good solubility for pesticides and low toxicity to Korean native water flea to establish new standard toxicity test methods using Korean native water flea for ecological risk assessment of pesticide. Four Korean freshwater cladocerans, Daphnia obtusa, Daphnia sp., Moina macrocopa and Simocephalus vetulus were exposed to 10 different organic solvents during 48 hours to evaluate their toxic response to solvents. Ethyl acetate was the most toxic to cladocerans tested. Although ethyl ether was the least toxic to cladocerans tested, it may not adequate as possible solvent in aquatic toxicity test due to high volatility and low water solubility. In conclusion, acetone, methanol, ethanol and acetonitrile which has low toxicity as well as good water solubility are recommended as optimal organic solvent to use in aquatic toxicity tests with Korean native cladocerans tested.

An Analysis and Evaluation of Current Cyber Home Learning Contents - Focused on the Earth Science Area of Science Course for the 10th Grade- (현행 사이버가정학습 콘텐츠의 분석 및 평가 -고등학교 1학년 과학과정의 지구과학 영역을 중심으로-)

  • Na, Jae-Joon
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.225-236
    • /
    • 2010
  • The purpose of this study is to analyze and evaluate the Cyber Home Learning contents of Earth science area in the basic course of the $10^{th}$ grade. For this purpose, we applied the 'Cyber Home Study Content Quality Control Tool' presented in Elementary Secondary Education e-Learning Quality Management Guidelines (Ver.2.0)' of Korea Education & Research Information Service(2008). The results of Cyber home learning contents analysis are as follow: First, it was presented that the study guide introduced the contents which should be studied for one class, properly. And it was not analyzed that the diagnosis assesment was not completed in the initiative study; Second, it was possible to study choosing the contents fitting the learner's level of learning in the main study, it was comprised of about 10 minutes. Third, it was performed without feedback for incorrect answers in the learning assessment, just the number of wrong questions. And the learning arrangement present the important contents learned in that class, summarizing and arranging again. The results of evaluating the contents in Cyber Home Learning are as follows: First, in evaluation section of instructional design, many text materials which were so difficult for learners to read were explained, being provided. Besides, the systematic structures leaves much to be desired, in view of learners' learning experience, contents, and environment. And in evaluation section of learning contents, the error of contents caused the learning contents not to appear, the amount of learning in each section was found too much. Second, in evaluation section of the strategy for Teaching and Learning, when we mention the strategy of Self Directed Learning, the environment to make learners search for information free and self-study possible was not possessed well. And in evaluation section of interaction, it was found that a simple click caused the learning to go on. Third, in evaluation section of evaluating, it was evaluated that there was wanting in consistency in learning aims, contents, evaluation contents.

  • PDF

PRESENT SITUATION AND PROSPECT OF PEDIATRIC DENTISTRY IN KOREA - FOCUSED ON MANAGEMENT OF DENTAL CARIES - (한국 소아치과의 현재와 전망 - 치아우식증관리 분야를 중심으로 -)

  • Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.39 no.2
    • /
    • pp.206-225
    • /
    • 2012
  • General status of pediatric dentistry in Korea is to conduct vigorous academic activities and specialized medical care centering the Korean Association of Pediatric Dentistry (KAPD) that has about 1,000 pediatric dentists as members, pediatric dentistry departments of 11 Colleges of Dentistry, numbers of pediatric dentistry training institutions and private clinics specialized in children. From 1996, the accredited pediatric dentists were produced by the KAPD and from 2008, the state began to produce the accredited pediatric dentists. Since then, doctors with expertise in pediatric care had opened private clinics in addition to the university hospitals, it became the basis of a momentum to deepen the specialty of pediatric dentistry. The Dentistry community of Korea is going through rapid and profound changes recently, and the underlying reasons for such changes can be classified largely into a few categories: (1) Decreasing population and structural changes in population (2) Increase in numbers of dentists, (3) Changes in the pattern of dental diseases and (4) Changes in medical environment. In Korea, the children population in the age range of 0 ~ 14 years old had been decreased by 2 million in 2010 compared to that of 2000 due to reduction of birth rate. The current population of children in the age range of 0 ~ 4 years old in 2010 takes up 16.2% of the total population, but it is estimated that such percentage would decrease to 8.0% by 2050. Such percentage is largely behind the estimated mean global population of 19.6% by 2050. On the other hand, the number of dentists had been largely increased from 18,000 in 2000 to 25,000 in 2010. And it is estimated that the number will be increased to 41,000 by 2030. In addition, the specialized personnel of Pediatric dentistry had been shown as increased by 2.5 times during past 10 years. For the changes in the pattern of dental diseases, including dental caries, each df rate of 5 years old children and 12 years old children had been decreased by 21.9% and 16.7% respectively in 2010 compared to 2000. Each df Index also had been decreased by 2.5 teeth and 1.2 teeth respectively. The medical expenditure of Korea is less than that of OECD and more specifically, the expenditure from the National Health Plan is less than OECD but the expenditure covered by households is larger than OECD. These facts indicate that it is considered as requiring the coverage of the national health plan to be reinforced more in the future and as such reinforcement needs continuous promotion. In medical examination pattern of Pediatric dentistry, the preventive and corrective treatment were increased whereas the restorative treatment was decreased. It is considered that such change is caused from decrease of dental caries from activation of the prevention project at national level. For the restorative treatment, the restorations in use of dental amalgam, pre-existing gold crowning and endodontic treatment had been decreased in their proportion while the restorative treatment in use of composite resin had been increased. It is considered that such changes is caused by the change of demands from patients and family or guardians as they desired more aesthetic improvement along with socio-economic growth of Korean society. Due to such changes in dentistry, the pediatric dentistry in Korea also attempts to have changes in the patterns of medical examination as follows; It tends to implement early stage treatment through early diagnosis utilizing various diagnostic tools such as FOTI or QLF. The early stage dental caries so called white spot had been included in the subjects for dental care or management and in order to do so, the medical care guidelines essentially accompanied with remineralization treatment as well as minimally invasive treatment is being generalized gradually. Also, centering the Pediatric dentists, the importance of caries risk assessment is being recognized, in addition that the management of dental caries is being changed from surgical approach to internal medicinal approach. Recently, efforts began to emerge in order to increase the target patients to be managed by dentists and to expand the application scope of Pediatric dentistry along with through such changes. The interest and activities of Pediatric dentists which had been limited to the medical examination room so far, is now being expanded externally, as they put efforts for participating in the preventive policy making process of the community or the state, and to support the political theories. And also opinions are being collected into the direction that the future- oriented strategic political tasks shall be selected and researches as well as presentations on the theoretical rationale of such tasks at the association level.